Study on J-integral with SENB specimens in a condenser material
Zheng-yi Ren , Er-jun Guo , Qing-fen Li
Journal of Marine Science and Application ›› 2004, Vol. 3 ›› Issue (1) : 91 -94.
Study on J-integral with SENB specimens in a condenser material
A series of tests was performed with three-point single-edge-notched-bend (SENB) specimens in a condenser material (Titanium alloy). Results show that the J-integral values of welded joint and HAZ are obviously smaller than those of the base metal. It signifies that the welding process can result in a reduced toughness of Titanium alloy and the effect of crack orientation on toughness value is not negligible for engineering applications. Besides, the J-integral values of L-T direction specimens are much higher than those of L-S ones. The J-integral values of rolled ring are: JC-R>JC-L>JL-R.
condenser material / Ti-alloy / J-integral / welding process / crack orientation
/
| 〈 |
|
〉 |