Abstract

Chloramphenicol(CAP) is an antifungal agent approved for use in aquarium. However, CAP residue imparts serious adverse effect on human health as well as the ecology. Thus, keeping track of CAP in aquatic products and its environmental metabolites are of great importance. Herein, we developed a novel and neat electrochemical aptasensor for the detection of simulated CAP residual in a sandwich fashion. The screen-printed carbon electrode was employed as the sensing platform and electrodeposited with peculiar nanogolds to enhance the electrochemical performance. For the specific recognition of such small target, a pair of chloramphenicol-binding aptamers, the primary Apt1 and the secondary Apt2, were tailored as an artificial single-chained antibody couple, of which the thiolated Apt1 stood on the coated working substrate to capture the analyte, while the biotinylated Apt2 rallied the signal output. In the presence of CAP, Apt1 at the lower place cooperated with the upper Apt2 pinched CAP together. After that, the reporter avidin-conjugated horseradish peroxidase associated atop the mounted biotin labels, resulting in an electrocatalytic amplification. In whole, this modular biosensing construction would set a paradigm not just for practicable checkpoint quarantine or point-of-care testing, but potentially adaptable for technological fusion with “Internet Plus” and “Internet of Things”.

Keywords

Chloramphenicol / Screen-printed carbon electrode / Electrochemical aptasensor / Electrochemical deposition

Cite this article

Download citation ▾
Mintong Yu, Tian Xia, Wanchen Bai, Jinyu Ji, Huan Wang, Yaqi Huang, Shengyuan Deng, Kefeng Ma, Yan Su, Ying Wan. Handheld Aptasensor for Sandwiched Detection of Chloramphenicol. Chemical Research in Chinese Universities, 2020, 36(2): 291-295 DOI:10.1007/s40242-020-9076-7

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Rico A, Phu T M, Satapornvanit K, Min J, Shahabuddin A M, Henriksson P J, Murray F J, Little D C, Dalsgaard A, van den Brink P J. Aquaculture, 2013, 412: 231.

[2]

Alderman D J, Hastings T S. International Journal of Food Science & Technology, 1998, 33: 139.

[3]

Benbrook C M. Institute for Agriculture and Trade Policy Report, 2002, Sandpoint, Idaho: The Northwest Science and Environmental Policy Center

[4]

Vignesh R, Karthikeyan B S, Periyasamy N, Devanathan K. South Asian Journal of Experimental Biology, 2011, 1: 114.

[5]

Cabello F C. Environmental Microbiology, 200, 8: 1137.

[6]

Mo W Y, Chen Z, Leung H M, Leung A O W. Environmental Science and Pollution Research, 2017, 24: 8978.

[7]

Santos L, Ramos F. International Journal of Antimicrobial Agents, 2018, 52: 135.

[8]

Broughton E I, Walker D G. Food Policy, 2010, 35: 471.

[9]

Liu X, Steele J C, Meng X Z. Environmental Pollution, 2017, 223: 161.

[10]

Zetts R M, Stoesz A, Smith B A, Hyun D Y. Pediatrics, 2018, 141: e20174124.

[11]

Shu X, Linet M, Gao R, Gao Y, Brinton L, Jin F, Fraumeni J R J. The Lancet, 1987, 330: 934.

[12]

Smith A G, Dovey G J, Cartwright R A. Pharmacoepidemiology and Drug Safety, 2000, 9: 215.

[13]

Yunis A A, Miller A M, Salem Z, Arimura G K. Clinical Toxicology, 1980, 17: 359.

[14]

Nagata T, Oka H. Journal of Agricultural and Food Chemistry, 199, 44: 1280.

[15]

Nicolich R S, Werneck-Barroso E, Marques M A S. Analytica Chimica Acta, 200, 565: 97.

[16]

Campbell G S, Mageau R P, Schwab B, Johnston R W. Antimicrobial Agents and Chemotherapy, 1984, 25: 205.

[17]

Conti G O, Copat C, Wang Z, D’Agati P, Cristaldi A, Ferrante M. Food Control, 2015, 50: 937.

[18]

Karaseva N A, Ermolaeva T N. Talanta, 2012, 93: 44.

[19]

Yadav S K, Agrawal B, Chandra P, Goyal R N. Biosensors and Bioelectronics, 2014, 55: 337.

[20]

Wan Y, Su Y, Zhu X, Liu G, Fan C. Biosensors and Bioelectronics, 2013, 47: 1.

[21]

Xu D, Huang X, Guo J, Ma X. Biosensors and Bioelectronics, 2018, 110: 78.

[22]

Dai Y, Liu C C. Angewandte Chemie International Edition, 2019, 58: 12355.

[23]

Song S, Wang L, Li J, Fan C, Zhao J. TrAC Trends in Analytical Chemistry, 2008, 27: 108.

[24]

Li M, Lv M, Wang L, Fan C, Zuo X. Current Opinion in Electrochemistry, 2019, 14: 71.

[25]

Zhu Y, Yan K, Xu Z, Wu J, Zhang J. Biosensors and Bioelectronics, 2019, 131: 79.

[26]

Khoshbin Z, Verdian A, Housaindokht M R, Izadyar M, Rouhbakhsh Z. Biosensors and Bioelectronics, 2018, 122: 263.

[27]

Xiao M, Lai W, Man T, Chang B, Li L, Chandrasekaran A R, Pei H. Chemical Reviews, 2019, 119: 11631.

[28]

Abnous K, Danesh N M, Ramezani M, Emrani A S, Taghdisi S M. Biosensors and Bioelectronics, 201, 78: 80.

[29]

Wang J, Xia Z, Su Y, Lu M, Wan Y, He Y. Applied Mechanics and Materials, 2017, 868: 340.

[30]

Wu J, Campuzano S, Halford C, Haake D A, Wang J. Anal Chem, 2010, 82: 8830.

[31]

Deng S, Yan J, Wang F, Su Y, Zhang X, Li Q, Liu G, Fan C, Pei H, Wan Y. Biosensors and Bioelectronics, 2019, 137: 263.

[32]

Su S., Wu Y., Zhu D., Chao J., Liu X., Wan Y., Su Y., Zuo X., Fan C., Wang L., Small, 2016, 12

[33]

Wang P, Wan Y, Deng S, Yang S, Su Y, Fan C, Aldalbahi A, Zuo X. Biosens. Bioelectron., 201, 86: 536.

AI Summary AI Mindmap
PDF

115

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/