Preparation of surface-enhanced Raman scattering(SERS)-active optical fiber sensor by laser-induced Ag deposition and its application in bioidentification of biotin/avidin

Chunyu Liu , Shaoyan Wang , Cuicui Fu , Haibo Li , Shuping Xu , Weiqing Xu

Chemical Research in Chinese Universities ›› 2015, Vol. 31 ›› Issue (1) : 25 -30.

PDF
Chemical Research in Chinese Universities ›› 2015, Vol. 31 ›› Issue (1) : 25 -30. DOI: 10.1007/s40242-015-4294-0
Article

Preparation of surface-enhanced Raman scattering(SERS)-active optical fiber sensor by laser-induced Ag deposition and its application in bioidentification of biotin/avidin

Author information +
History +
PDF

Abstract

A surface-enhanced Raman scattering(SERS) optical fiber sensor was prepared by the laser-induced deposition of Ag nanoparticle membrane on a silica optical fiber tip, which was applied to the real time SERS spectral monitoring on the biorecognition of biotin/avidin. The bioidentification of biotin/avidin was carried out through a indirect method, in which the bioidentification is based on the SERS response signal of a labeled dye(Atto610) after its fluorescence has been quenched totally by the deposited Ag nanoparticle membrane. By SERS monitoring the bioidentification process of biotin/avidin, it has been found that this recognition process is finished in 40 min. The lowest detection concentration of biotin is 1.0×10−7 mg/mL. This research is promising in the application of immunoassays on line and in vivo.

Keywords

Process monitoring / Photochemical method / Laser-inducement / SERS-active optical fiber / Biotin/avidin / Specific identification

Cite this article

Download citation ▾
Chunyu Liu, Shaoyan Wang, Cuicui Fu, Haibo Li, Shuping Xu, Weiqing Xu. Preparation of surface-enhanced Raman scattering(SERS)-active optical fiber sensor by laser-induced Ag deposition and its application in bioidentification of biotin/avidin. Chemical Research in Chinese Universities, 2015, 31(1): 25-30 DOI:10.1007/s40242-015-4294-0

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Fleischmann M, Hendra P J, MeQuillan A J. Chem. Phys. Lett., 1974, 26: 163.

[2]

Jeanmaire D L, Van Duyne R P. J. Electroanal. Chem., 1977, 84: 1.

[3]

Nie S M, Emory S R. Science, 1997, 275: 1102.

[4]

Kneipp K, Yang W, Harald K, Perelman L T, Itzkan I, Dasari R R, Feld M S. Phys. Rev. Lett., 1997, 78: 1667.

[5]

Li J F, Huang Y F, Ding Y, Yang Z L, Li S B, Zhou X S, Fan F R, Zhang W, Zhou Z Y, Wu Y D, Ren B, Wang Z L, Tian Z Q. Nature, 2010, 464: 392.

[6]

Cao Y C, Jin R, Mirkin C A. Science, 2002, 297: 1536.

[7]

Chen Z, Tabakman S M, Goodwin A P, Kattah M G, Daranciang D, Wang X, Zhang G, Li X, Liu Z, Utz P J, Jiang K, Fan S, Dai H. Nat. Biotech., 2008, 26: 1285.

[8]

Graham D, Thompson D G, Smith W E, Faulds K. Nat. Nanotechnol., 2008, 3: 548.

[9]

Downes A, Elfick A. Sensors, 2010, 10: 1871.

[10]

Smith W E. Chem. Soc. Rev., 2008, 37: 955.

[11]

Pozzi F, Lombardi J R, Bruni S, Leona M. Anal. Chem., 2012, 84: 3751.

[12]

Jurasekova Z, Domingo C, Garcia-Ramos J V, Sanchez-Cortes S. J. Raman Spectrosc., 2008, 39: 1309.

[13]

Jurasekova Z, del Puerto E, Bruno G, Garcia-Ramos J V, Sanchez-Cortes S, Domingo C. J. Raman Spectrosc., 2010, 41: 1455.

[14]

Lee P C, Meisel D. J. Phys. Chem., 1982, 86: 3391.

[15]

Frens G. Nature Phys. Sci., 1973, 241: 20.

[16]

Tao J L, Tang B, Xu S P, Pan L Y, Xu W Q. Chem. Res. Chinese Univerisites, 2012, 28(3): 488.

[17]

Lim I I S, Pan Y, Mott D, Ouyang J, Njoki P N, Luo J, Zhou S, Zhong C J. Langmuir, 2007, 23: 10715.

[18]

Alvarez-Puebla R A, Zubarev E R, Kotov N A, Liz-Marzan L M. Nano Today, 2012, 7: 6.

[19]

Guo H Y, Xu S P, Tang B, Tao J L, Pan L Y, Xu W Q. Chem. J. Chinese Universities, 2012, 33(10): 2308.

[20]

Yang L B, Ruan W D, Jiang X, Zhao B, Xu W Q, Lombardi J R. J. Phys. Chem. C, 2008, 113: 117.

[21]

Xue X X, Ji W, Mao Z, Mao H J, Wang Y, Wang X, Ruan W D, Zhao B, Lombardi J R. J. Phys. Chem. C, 2012, 116: 8792.

[22]

Liu K, Xu M M, Guo Q H, Yao J L, Gu R A. Chem. J. Chinese Universities, 2012, 33(11): 2516.

[23]

Choi D, Choi Y, Hong S, Kang T, Lee P R. Small, 2010, 6: 1741.

[24]

Wang X, Xu S, Li H, Tao J, Zhao B, Xu W. J. Raman Spectrosc., 2012, 43: 459.

[25]

Niidome Y, Hori A, Takahashi H, Goto Y, Yamada S. Nano Lett., 2001, 1: 365.

[26]

Takahashi H, Niidome Y, Sato T, Yamada S. Colloid Surface A, 2004, 247: 105.

[27]

Bjerneld E J, Murty K V G K, Prikulis J, Käll M. Chem.Phys.Chem., 2002, 3: 116.

[28]

Bjerneld E J, Svedberg F, Käll M. Nano Lett., 2003, 3: 593.

[29]

Xu B B, Ma Z C, Wang L, Zhang R, Niu L, Yang G Z, Zhang Y L, Zheng W H, Zhao B, Xu Y, Chen Q D, Xia H, Sun H B. Lab on a Chip, 2011, 11: 3347.

[30]

Xu B B, Zhang R, Liu X Q, Wang H, Zhang Y L, Jiang H B, Wang L, Ma Z C, Ku J F, Xiao F S, Sun H B. Chem. Commun., 2012, 48: 1680.

[31]

Ligler F S, Anderson G P, Taitt C R. Optical Biosensors: Today and Tomorrow, 2008 2nd Edn. Amsterdam: Elsevier Science 83.

[32]

Lin Y B, Zou Y, Lindquist R G. Biomed. Opt. Express, 2011, 2: 478.

[33]

Cheng S F, Chau L K. Anal. Chem., 2003, 75: 16.

[34]

Deiss F, Sojic N, White D J, Stoddart P R. Anal. Bioanal. Chem., 2010, 396: 53.

[35]

Sato H, Tanaka T, Ikeda T, Wada S, Tashiro H, Ozaki Y. J. Mol. Struct., 2001, 598: 93.

[36]

Yamamoto Y S, Oshima Y, Shinzawa H, Katagiri T, Matsuura Y, Ozaki Y, Sato H. Anal. Chim. Acta, 2008, 619: 8.

[37]

Mitsuoka H, Morita S I, Suzuki T, Matsuura Y, Katsumoto Y, Sato H. Appl. Phys. Express., 2009, 2: 027001.

[38]

Komachi Y, Katagiri T, Sato H, Tashiro H. Appl. Opt., 2009, 48: 1683.

[39]

Katagiri T, Yamamoto Y S, Ozaki Y, Matsuura Y, Sato H. Appl. Spectrosc., 2009, 63: 103.

[40]

Wang X D, Wolfbeis O S. Anal. Chem., 2013, 85: 487.

[41]

Sergey M B, Wolfbeis O S. Chem. Rev., 2008, 108: 423.

[42]

Emory S R, Nie S M. Anal. Chem., 1997, 69: 2631.

[43]

Xu W Q, Xu S P, Hu B, Wang K X, Zhao B, Xie Y T, Fan Y G. Chem. J. Chinese Universities, 2004, 25(1): 144.

[44]

Zheng X L, Zhao X J, Guo D W, Tang B, Xu S P, Zhao B, Xu W Q, Lombardi J R. Langmuir, 2009, 25: 3802.

[45]

Jia S J, Xu S P, Zheng X L, Zhao B, Xu W Q. Chem. J. Chinese Universities, 2006, 27(3): 523.

[46]

Liu T, Xiao X, Yang C. Langmuir, 2011, 27: 4623.

[47]

Li M S, Yang C X. Chinese Phys. Lett., 2010, 27: 044202.

[48]

Han X X, Kitahama Y, Itoh T, Wang C X, Zhao B, Ozaki Y. Anal. Chem., 2009, 81: 3350.

[49]

Liu Y, Xu S P, Xuan X Y, Zhao B, Xu W Q. J. Phys. Chem. Lett., 2011, 2: 2218.

AI Summary AI Mindmap
PDF

138

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/