Ionic liquid-based microwave-assisted liquid-liquid microextraction and high performance liquid chromatography determination of sulfonamides from animal oils

Xu-dong Feng , Fang-hui Liang , Rui Su , Li-jie Wu , Xue-yuan Li , Xing-hua Wang , Han-qi Zhang , Ai-min Yu

Chemical Research in Chinese Universities ›› 2013, Vol. 29 ›› Issue (4) : 647 -652.

PDF
Chemical Research in Chinese Universities ›› 2013, Vol. 29 ›› Issue (4) : 647 -652. DOI: 10.1007/s40242-013-2516-x
Article

Ionic liquid-based microwave-assisted liquid-liquid microextraction and high performance liquid chromatography determination of sulfonamides from animal oils

Author information +
History +
PDF

Abstract

The authors performed ionic liquid-based microwave-assisted liquid-liquid microextraction(IL-based MALLME) coupled with high performance liquid chromatographic separation for the determination of 6 sulfonamides (SAs) from animal oils. The target analytes were extracted from animal oil samples with sodium hydroxide solution containing 1-butyl-3-methylimidazolium tetrafluoroborateand as the extraction solvent under microwave irradiation. The experimental parameters of the IL-based MALLME, including types of ILs, volume of IL, amount of ion-pairing agent(NH4PF6), pH value of sample solution, and extraction temperature and time were evaluated. The limits of detection and quantification obtained were in a range of 0.4–0.5 μg/kg and a range of 1.2–1.8 μg/kg, respectively. The accuracy of the method was evaluated by analyzing five spiked animal oil samples at two fortified levels(5 and 50 μg/kg), and the recoveries of SAs varied from 81.4% to 114.5% with relative standard deviations ranging from 0.8% to 9.0%.

Keywords

Ionic liquid-based microwave-assisted liquid-liquid microextraction(IL-based MALLME) / High performance liquid chromatography(HPLC) / Sulfonamide / Animal oil

Cite this article

Download citation ▾
Xu-dong Feng, Fang-hui Liang, Rui Su, Li-jie Wu, Xue-yuan Li, Xing-hua Wang, Han-qi Zhang, Ai-min Yu. Ionic liquid-based microwave-assisted liquid-liquid microextraction and high performance liquid chromatography determination of sulfonamides from animal oils. Chemical Research in Chinese Universities, 2013, 29(4): 647-652 DOI:10.1007/s40242-013-2516-x

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Franco D A, Webb J, Taylor C E. J. Food Prot., 1990, 53: 178.

[2]

Wegener H C, Aarestrup F M, Gerner-Smidt P, Bager F. Acta Vet. Scand. Suppl., 1999, 92: 51.

[3]

Anadòn A, Martìnez-Larrañaga M R. Livest. Prod. Sci., 1999, 59: 183.

[4]

Ministry of Agriculture of the People’s Republic of China. Establishment of Maximum Reside Levels of Veterinary Medical Products in Foodstuffs of Animal Origin, Regulation No.235, 2002, Beijing: Standards Press of China.

[5]

Meng Z, Liu Y, Shan L, Jin Q, Wang X. J. Am. Oil Chem. Soc., 2010, 87: 1435.

[6]

Kowalski C J, Łebkowska-Wieruszewska B, Osypiuk M. J. Chromatogr. B, 2009, 877: 1787.

[7]

Heller D N, Ngoh M A, Donoghue D, Podhorniak L, Righter H, Thomas M H. J. Chromatogr. B, 2002, 774: 39.

[8]

Tao Y, Liu J F, Hu X L, Li H C, Wang T, Jiang G B. J. Chromatog. A, 2009, 1216: 6259.

[9]

Biswas A K, Rao G S, Kondaiah N, Anjaneyulu A S R, Malik J K. J. Agric. Food Chem., 2007, 55: 8845.

[10]

Won S Y, Lee C H, Chang H S, Kim S O, Lee S H, Kim D S. Food Control, 2011, 22: 1101.

[11]

Stoev G, Michailova A. J. Chromatogr. A, 2000, 871: 37.

[12]

Tsai W H, Chuang H Y, Chen H H, Wu Y W, Cheng S H, Huang T C. J. Chromatogr. A, 2010, 1217: 7812.

[13]

Cai Z, Zhang Y, Pan H, Tie X, Ren Y. J. Chromatogr. A, 2008, 1200: 144.

[14]

Berardi G, Bogialli S, Curini R, Corcia A D, Lagana A. J. Agric. Food Chem., 2006, 54: 4537.

[15]

Shao B, Dong D, Wu Y, Hu J, Meng J, Tu X, Xu S. Anal. Chim. Acta, 2005, 546: 174.

[16]

Rodriguez E, Moreno-Bondi M C, Marazuela M D. J. Chromatogr. A, 2008, 1209: 136.

[17]

Cacho J, Ferreira V, Fernandez P. Anal. Chim. Acta, 1992, 264: 311.

[18]

Guidotti M. J. High Resolut. Chromatogr., 1996, 19: 469.

[19]

Aubert C, Baumann S, Arguel H. J. Agric. Food Chem., 2005, 53: 8881.

[20]

Wen Y, Zhang M, Zhao Q, Feng Y Q. J. Agric. Food Chem., 2005, 53: 8468.

[21]

Huang X Y, Qiu N N, Yuan D X. J. Chromatogr. A, 2009, 1216: 8240.

[22]

Lin C Y, Huang S D. Anal. Chim. Acta, 2008, 612: 37.

[23]

Zheng M M, Ruan G D, Feng Y Q. J. Chromatogr. A, 2009, 1216: 7510.

[24]

López-Darias J, Pino V, Ayala J H, Afonso A M. Microchim Acta, 2011, 174: 213.

[25]

Abraham M H, Zissimos A M, Huddleston J G, Willauer H D, Rogers R D, Acree W E. Ind. Eng. Chem. Res., 2003, 42: 413.

[26]

Adams C J, Earle M J, Seddon K R. Green Chem., 2000, 2: 21.

[27]

Earle M J, McCormac P, Seddon K R. Green Chem., 1999, 1: 23.

[28]

Herrera-Herrera A V, Hernández-Borges J, Rodríguez-Delgado M A. Anal. Bioanal. Chem., 2008, 392: 1439.

[29]

Wang Y, You J, Ren R, Xiao Y, Gao S, Zhang H, Yu A. J. Chromatogr. A, 2010, 1217: 4241.

[30]

Yan Q, Fang Y Y, Shu Q X, Shen Y, Pei S M. J. Chem. Eng. Data, 2011, 56: 2379.

[31]

Neves C M S S, Batista M L S, Cláudio A F M, Santos L M N B F, Marrucho I M, Freire M G, Coutinho J A P. J. Chem. Eng. Data, 2010, 55: 5065.

[32]

Dong T, Xu Y Q, Chen F W, Chi Y N, Hu C W. Chem. Res. Chinese Universities, 2011, 27(2): 177.

[33]

Richard P S, Ann E V, Matthew R, Grant A B, Lindsy M F, John D H, Robin D R. Chem. Commun., 2001, 20: 2070.

[34]

Dong X, Justin R R, Larry G H, Sheng F L, Richard A B, Edward L Q. J. Phys. Chem. B, 2008, 112: 13316.

[35]

Gentili A, Perret D, Marchese S. Trends Anal. Chem., 2005, 24: 704.

[36]

Ito Y, Oka H, Ikai Y, Matsumoto H, Miyazaki Y, Nagase H. J. Chromatogr. A, 2000, 898: 95.

[37]

Berrada H, Borrull F, Font G, Marcé R M. J. Chromatogr. A, 2008, 1208: 83.

[38]

Kowalski P, Plenis A, Olędzka I, Konieczna L. J. Pharm. Biomed. Anal., 2011, 54: 160.

[39]

Kaufmann A, Butcher P, Kolbener P. Rapid Commun. Mass Spectrom., 2003, 17: 2575.

[40]

Baghdadi M, Shemirani F. Anal. Chim. Acta, 2009, 634: 186.

AI Summary AI Mindmap
PDF

182

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/