Seismic performance of self-centering rocking bridge piers using inclined tendons

Sepehr Rassoulpour , Mohammad Safi , Mahmoud R. Shiravand

Advances in Bridge Engineering ›› 2026, Vol. 7 ›› Issue (1) : 42

PDF
Advances in Bridge Engineering ›› 2026, Vol. 7 ›› Issue (1) :42 DOI: 10.1186/s43251-026-00229-0
Original Innovation
research-article
Seismic performance of self-centering rocking bridge piers using inclined tendons
Author information +
History +
PDF

Abstract

Self-centering (SC) rocking piers can bring the bridge back toward its initial position by employing restoring forces made by post-tensioned tendons. The tendons can be vertically post-tensioned or made at any angle other than 90° to the horizontal direction. However, the axial stiffness of the inclined tendons may play a more significant role in resisting the lateral seismic load than vertical tendons, which increase their elongation. Therefore, inclined tendons yield sooner, and their allowable initial stress has a lower value to prevent tendons’ yield. There is an angle corresponding to the zero post-tensioning (PT) force, and the tendons cannot become closer to the horizontal direction than that. In the present study, the force-displacement relationship of the SC rocking pier, which is post-tensioned with a tendon at an arbitrary angle, is derived. Moreover, the equation determining the elongation of the tendons is obtained, which gives the minimum allowable angle of the tendons. Cyclic analyses were performed to investigate the behavior of the model. Then, non-linear incremental dynamics analyses were conducted using selected earthquake records. Fragility curves considering the maximum drift and residual drift as engineering demand parameters (EDPs) were derived. The results showed that using SC rocking piers with oblique non-post-tensioned tendons significantly reduces the residual drift, reducing the probability of emergency usage interruption even more efficiently than the corresponding vertically post-tensioned pier. SC rocking piers with non-post-tensioned oblique tendons are proposed as a suitable alternative for SC piers with post-tensioned vertical tendons.

Keywords

Self-centering piers / Inclined tendons / Residual drift / Non-post-tensioned tendons / Post-tensioning force

Cite this article

Download citation ▾
Sepehr Rassoulpour, Mohammad Safi, Mahmoud R. Shiravand. Seismic performance of self-centering rocking bridge piers using inclined tendons. Advances in Bridge Engineering, 2026, 7 (1) : 42 DOI:10.1186/s43251-026-00229-0

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

AASHTO (2014) AASHTO LRFD bridge design specification, 7th edn. Washington, D.C

[2]

Ajrab JJ, Pekcan G, Mander JB. Rocking wall–frame structures with supplemental tendon systems. J Struct Eng, 2004, 130(6): 895-903

[3]

Anzabi PP, Shiravand M. Seismic reliability analysis of self-centering post-tensioned piers under influence of prestress loss. Eng Struct, 2024, 314118315

[4]

Anzabi PP, Shiravand MR. Segments arrangement effect on improvement of self-centering precast post-tensioned segmental piers seismic performance. Struct Concr, 2024, 25(1): 185-206

[5]

Ashouri R, Shiravand MR. Damage assessment of self-centering rocking piers using an input energy-based damage prediction model coupled with self-centering index. Struct Concr, 2024, 25(5): 3549-3569

[6]

Bu Z, Guo J, Zheng R, Song J, Lee GC. Cyclic performance and simplified pushover analyses of precast segmental concrete bridge columns with circular section. Earthq. Eng. Eng. Vib, 2016, 15(2): 297-312

[7]

Cao Z, Wang H, Guo T. Fragility analysis of self-centering prestressed concrete bridge pier with external aluminum dissipators. Adv Struct Eng, 2017, 20(8): 1210-1222

[8]

Chang G, Mander JB. Seismic energy based fatigue damage analysis of bridge columns: part I-Evaluation of seismic capacity, 1994, Buffalo, NY: National Center for Earthquake Engineering Research

[9]

Dawood HM, ElGawady M. Performance-based seismic design of unbonded precast post-tensioned concrete filled GFRP tube piers, composites part B. Compos Part B, 2013, 44(1): 357-367

[10]

Dong H, Du X, Han Q, Hao H, Bi K, Wang X. Performance of an innovative self-centering buckling restrained brace for mitigating seismic responses of bridge structures with double-column piers. Eng Struct, 2017, 148: 47-62

[11]

Eatherton MR, Fahnestock LA, Miller DJ. Computational study of self-centering buckling-restrained braced frame seismic performance. Earthq Engng Struct Dyn, 2014, 43(13): 1897-1914

[12]

ElGawady MA, Ma Q, Butterworth JW, Ingham J. Effects of interface material on the performance of free rocking blocks. Earthq Engng Struct Dyn, 2011, 40(4): 375-392

[13]

ElGawady MA, Sha’lan A. Seismic behavior of self-centering precast segmental bridge bents. J Bridge Eng, 2011, 16(3): 328-339

[14]

FEMA (2009) Quantification of building seismic performance factors. FEMA, Washington, DC

[15]

Guerrini G, Restrepo JI, Massari M, Vervelidis A. Seismic behavior of posttensioned self-centering precast concrete dual-shell steel columns. J Struct Eng, 2015, 141(4):04014115

[16]

Guo T, Cao Z, Xu Z, Lu S. Cyclic load tests on self-centering concrete pier with external dissipators and enhanced durability. J Struct Eng, 2016, 142(1):04015088

[17]

Han Q, Jia Z, Xu K, Zhou Y, Du X. Hysteretic behavior investigation of self-centering double-column rocking piers for seismic resilience. Eng Struct, 2019, 188: 218-232

[18]

Hensley GM, Plaut RH. Three-dimensional analysis of the seismic response of guyed masts. Eng Struct, 2007, 29(9): 2254-2261

[19]

Hosseini SM, Poorahad P, Shiravand MR (2026) Code-based data-driven platform for the prediction of cyclic backbone curves of self-centering post-tensioned piers. Adv Struct Eng 13694332261420443. https://doi.org/10.1177/13694332261420443

[20]

Ichikawa S, Matsuzaki H, Moustafa A, ElGawady MA, Kawashima K. Seismic-resistant bridge columns with ultrahigh-performance concrete segments. J Bridge Eng, 2016, 21(9):04016049

[21]

Itoh Y, Wada M, Liu C (2005) Lifecycle environmental impact and cost analyses of steel bridge piers with seismic risk. In Proceedings of the 9th international conference on structural safety and reliability

[22]

Lee WK, Billington SL. Modeling residual displacements of concrete bridge columns under earthquake loads using fiber elements. J Bridge Eng, 2010, 15(3): 240-249

[23]

Marriott DJ (2009) The development of high-performance post-tensioned rocking systems for the seismic design of structures

[24]

Mashal M, Palermo A. Low-damage seismic design for accelerated bridge construction. J Bridge Eng, 2019, 24(7):04019066

[25]

Mazzoni S, McKenna F, Scott MH, Fenves GL (2006) OpenSees command language manual, Pacific Earthquake Engineering Research (PEER) center 264:137–158

[26]

Menegotto M (1973) Method of analysis for cyclically loaded RC plane frames including changes in geometry and non-elastic behavior of elements under combined normal force and bending. In Proc. of IABSE Symposium on Resistance and Ultimate Deformability of Structures Acted on by Well Defined Repeated Loads

[27]

Mitoulis SA, Rodriguez JR. Seismic performance of novel resilient hinges for columns and application on irregular bridges. J Bridge Eng, 2017, 22(2):04016114

[28]

Omidian P, Khaji N, Aghakouchak A. A logical retrofit strategy optimization framework for resiliency bridge infrastructure management considering life-cycle cost, Sustain Struct. Sustain Struct, 2024, 4(1):000036

[29]

Omidian P, Khaji N, Aghakouchak AA. An integrated decision-making approach to resilience–LCC bridge network retrofitting using a genetic algorithm-based framework. Resilient Cities Struct, 2025, 4(1): 16-40

[30]

Ou Y-C, Chiewanichakorn M, Aref AJ, Lee GC. Seismic performance of segmental precast unbonded posttensioned concrete bridge columns. J Struct Eng, 2007, 133(11): 1636-1647

[31]

Ou Y-C, Pratiwi AY, Song J. Pseudodynamic testing and inelastic displacement ratios of self-centering precast concrete segmental bridge columns. J Struct Eng, 2018, 144(9):04018158

[32]

Palermo A, Pampanin S, Calvi GM. Concept and development of hybrid solutions for seismic resistant bridge systems. J Eart Eng, 2005, 9(6): 899-921

[33]

Parvanehro P, Shiravand M, Safi M. A method for linear response analysis of long bridges under multi-support seismic excitation. Bull Earthquake Eng, 2022, 20(15): 8381-8410

[34]

Rassoulpour S, Shiravand M, Safi M. Proposed seismic-resistant dual system for continuous-span concrete bridges using self-centering cores. Eng Struct, 2023, 274115181

[35]

Rassoulpour S, Shiravand MR (2024) Seismic assessment of self-centering piers in RC bridges with substructure irregularity. In World Conference on Earthquake Engineering proceedings

[36]

Rassoulpour S, Shiravand MR, Safi M. Effect of soil-structure interaction on seismic behavior of self-centering rocking piers supported on shallow foundations. Soil Dyn Earthquake Eng, 2025, 194109339

[37]

Sabagh NG, Shiravand MR (2026) Seismic performance assessment of irregular self-centering rocking dual-column piers, Sci Rep

[38]

Sideris P, Aref AJ, Filiatrault A. Large-scale seismic testing of a hybrid sliding-rocking posttensioned segmental bridge system. J Struct Eng, 2014, 140(6):04014025

[39]

Sun Z, Wang D, Bi K, Si B. Experimental and numerical investigations on the seismic behavior of bridge piers with vertical unbonded prestressing strands. Bull Earthquake Eng, 2016, 14(2): 501-527

[40]

Wang Z, Wang J-Q, Liu T-X, Zhang J. An explicit analytical model for seismic performance of an unbonded post-tensioned precast segmental rocking hollow pier. Eng Struct, 2018, 161: 176-191

[41]

Xia X, Zhang X, Shi J, Tang J. Seismic isolation of railway bridges using a self-centering pier. Smart Struct Syst, 2021, 27: 447-455

[42]

Xiao Y, Eberhard MO, Zhou Y, Stanton JF. Proportioning of self-centering energy dissipative braces. Earthq Engng Struct Dyn, 2021, 50(10): 2613-2633

[43]

Xu L, Liu J, Li Z. Cyclic behaviors of steel plate shear wall with self-centering energy dissipation braces. J Constructional Steel Res, 2019, 153: 19-30

Rights & permissions

The Author(s)

PDF

0

Accesses

0

Citation

Detail

Sections
Recommended

/

〈 〉