Research of physical and mechanical characteristics of suture material in experiment in operations on liver

Vyacheslav A. Lipatov , Dmitriy A. Severinov , Artem A. Denisov , Sergey V. Lazarenko , Nikolay N. Grigor’yev

I.P. Pavlov Russian Medical Biological Herald ›› 2020, Vol. 28 ›› Issue (2) : 193 -199.

PDF (483KB)
I.P. Pavlov Russian Medical Biological Herald ›› 2020, Vol. 28 ›› Issue (2) : 193 -199. DOI: 10.23888/PAVLOVJ2020282193-199
Original study
research-article

Research of physical and mechanical characteristics of suture material in experiment in operations on liver

Author information +
History +
PDF (483KB)

Abstract

Taking into account the peculiarities of the blood supply to the liver and the structure of its parenchyma, and, as a result, considerable difficulties in providing reliable hemostasis without additional traumatization, a surgeon needs to be careful when performing a surgical manipulation. Despite a large number of modern methods for stopping parenchymal bleeding, many practi-tioners give preference to classic methods of hemostasis, including ligation of bleeding vessels in the bulk of the organ using specialized sutures. One of the most serious complications of the use of suture material is cutting of organ tissue, which leads to enhanced bleeding and expansion of the area of damage. At the moment, the tactics of choosing suture material for surgical procedures is empirical. In this context, the aim of this study was to assess the physico-mechanical properties of suture material regarding its structure, and to develop a criterion for choosing surgical sutures for surgical procedures. For the study, the liver was removed out of corpses of males of 35 to 40 years of age, after which separate sections of 7.5×7×4 cm in size were obtained from it. Then a wound 3 cm long and 2 cm deep was made. The wound was sutured with a simple interrupted suture without tightening, but with application of one simple half-node. For suturing, catgut, twisted capron and polyglycolide thread were used. Attention was paid to the maximal force applied at the moment of cutting (Fmax) and the degree of pulling the thread at the moment of cutting (Lu). The analysis of the data was based on comparison of Fmax and Lu parameters. This method permits to refuse from the empirical approach to the choice of suture material for operations on the liver, and to develop a criterion for choosing surgical sutures.

Keywords

hemostasis / liver / suture material / physical and mechanical properties

Cite this article

Download citation ▾
Vyacheslav A. Lipatov, Dmitriy A. Severinov, Artem A. Denisov, Sergey V. Lazarenko, Nikolay N. Grigor’yev. Research of physical and mechanical characteristics of suture material in experiment in operations on liver. I.P. Pavlov Russian Medical Biological Herald, 2020, 28(2): 193-199 DOI:10.23888/PAVLOVJ2020282193-199

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Açan E, Hapa O, Barber FA. Mechanical Properties of Suture Materials. In: Akgun U., Karahan M., Randelli P., et al., editors. Knots in Orthopedic Surgery. Springer, Berlin, Heidelberg; 2017. P. 21-31. doi:10.1007/978-3-662-56108-9_3

[2]

Açan E., Hapa O., Barber F.A. Mechanical Properties of Suture Materials. In: Akgun U., Karahan M., Randelli P., et al., editors. Knots in Orthopedic Surgery. Springer, Berlin, Heidelberg; 2017. P. 21-31. doi:10.1007/978-3-662-56108-9_3

[3]

Vinnik YuS, Markelova NM, Shishatskaya ЕI, et al. Immunohistochemical Markers of Local Tissue Response to the Implantation of Products Made from PHA. Journal of Siberian Federal University. Biology. 2016;9(1):109-20. (In Russ). doi:10.17516/ 1997-1389-2015-9-1-109-120

[4]

Винник Ю.С., Маркелова Н.М., Шишацкая Е.И., и др. Иммуногистохимические маркеры местной реакции тканей при имплантации изделий из ПГА // Журнал Сибирского федерального университета. Серия: Биология. 2016. Т. 9, №1. С. 109-120. doi:10.17516/1997-1389-2015-9-1-109-120

[5]

Radojkovic M, Stojkovic M, Golubovic I, et al. The influence of various microenvironmental factors on biomechanical features of different suture materials used in hepato-pancreato-biliary surgery. Facta universitatis. Series: Medicine and Biology. 2019; 21(3):95-100. doi:10.22190/FUMB190625015R

[6]

Radojkovic M., Stojkovic M., Golubovic I. et al. The influence of various microenvironmental factors on biomechanical features of different suture materials used in hepato-pancreato-biliary surgery // Facta universitatis. Series: Medicine and Biology. 2019. Vol. 21, №3. P. 95-100. doi:10.22190/FUMB 190625015R

[7]

Severinov DA, Denisov AA, Ananjan TT. Shvy parenhimatoznyh organov: preimushhestva i nedostatki. In: Problemy gemostaza v hirurgii XXI veka; 2017 May 18-19. Kursk; 2017. P. 17-20. Available at: http://conferencinnova.ru/images/hemo2017/hemo 2017.pdf. Accessed: 2019 December 12. (In Russ).

[8]

Северинов Д.А., Денисов А.А., Ананян Т.Т. Швы паренхиматозных органов: преимущества и недостатки. В сб.: Проблемы гемостаза в хирургии ХХI века; 18-19 мая 2017. Курск; 2017. С. 17-20. Доступно по: http://conferencinnova.ru/ images/hemo2017/hemo2017.pdf. Ссылка активна на 12.12.2019.

[9]

Zhukovskiy VА. Modern suture materials and other fiber implants. Main trend. In: Conference «Biotechnology and quality of life»; 2014 March 18-20. Moscow; 2014. P. 505-506. Available at: http:// www.spsl.nsc.ru/FullText/konfe/bio2014_tezis.pdf. Accessed: 2019 December 12. (In Russ).

[10]

Жуковский В.А. Современные шовные материалы и другие волоконные имплантаты. Основные тенденции. В сб.: Международная научно-практическая конференция «Биотехнология и качество жизни»; 18-20 марта 2014. М.; 2014. С. 505-506. Доступно по: http://www.spsl.nsc.ru/ FullText/konfe/bio2014_tezis.pdf. Ссылка активна на 12.12.2019.

[11]

Arshakyan VA, Gynter VE, Shtofin SG, et al. Ways of improvement of surgical sutural material. ActaBiomedica Scientifica. 2017;2(6(118)):193-7. (In Russ). doi:10.12737/article_5a0a910977eca1.04637486

[12]

Аршакян В.А., Гюнтер В.Э., Штофин С.Г., и др. Пути совершенствования шовного материала в хирургии // Acta Biomedica Scientifica. 2017. Т. 2, №6 (118). С. 193-197. doi:10.12737/article_ 5a0a910977eca1.04637486

[13]

Meyer DC, Bachmann E, Lädermann A, et al. The best knot and suture configurations for high-strength suture material. An in vitro biomechanical study. Orthopaedics & Traumatology, Surgery & Research. 2018;104(8):1277-82. doi:10.1016/j.otsr. 2018.08.010

[14]

Meyer D.C., Bachmann E., Lädermann A., et al. The best knot and suture configurations for high-strength suture material. An in vitro biomechanical study // Orthopaedics & Traumatology, Surgery & Research. 2018. Vol. 104, №8. P. 1277-1282. doi: 10.1016/j.otsr.2018.08.010

[15]

Zhang G., Zeng X., Su Y., et al. Influence of suture size on the frictional performance of surgical suture evaluated by a penetration friction measurement approach. Journal of the Mechanical Behavior of Biomedical Materials. 2018;80:171-9. doi:10.1016/ j.jmbbm.2018.02.003

[16]

Zhang G., Zeng X., Su Y., et al. Influence of suture size on the frictional performance of surgical suture evaluated by a penetration friction measurement approach // Journal of the Mechanical Behavior of Biomedical Materials. 2018. Vol. 80. P. 171-179. doi:10.1016/j.jmbbm.2018.02.003

[17]

Lazarenko VA, Bobrovskaja EA. Biosovmestimost' v zone «protez – arterija – shovnyj material» s pozicii stenoticheskih okkljuzij posle rekonstruktivno-vosstanovitel'nyh operacij. In: Materials of the International scientific-practical conference «Medical implants»; 2016 March 18-19. Kursk; 2016. P. 71-2. Available at: http://conferencinnova. ru/images/cbooks/Sbornik_materialov_konferentsii_-_Med_ implanty_-_2016.pdf. Accessed: 2019 December 12. (In Russ).

[18]

Лазаренко В.А., Бобровская Е.А. Биосовместимость в зоне «протез – артерия – шовный материал» с позиции стенотических окклюзий после реконструктивно-восстановительных операций. В сб.: Материалы Международной научно-практической конференции «Медицинские импланты»; 18-19 марта 2016. Курск; 2016. С. 71-72. Доступно по: http://conferencinnova.ru/images/ cbooks/Sbornik_materialov_konferentsii_-_Med_ implanty_-_2016.pdf. Ссылка активна на 12.12.2019.

[19]

Abellán D, Nart J, Pascual A, et al. Cohen and others. Physical and Mechanical Evaluation of Five Suture Materials on Three Knot Configurations: An in Vitro Study. Polymers. 2016;(8):147. doi:10.3390/ polym8040147

[20]

Abellán D., Nart J., Pascual A., et al. Cohen and others. Physical and Mechanical Evaluation of Five Suture Materials on Three Knot Configurations: An in Vitro Study // Polymers. 2016. №8 (4). P. 147. doi:10.3390/polym8040147

[21]

Johnson PC, Roberts AD, Hire JM, et al. The effect of instrumentation on suture tensile strength and knot pullout strength of common suture materials. Journal of Surgical Education. 2016;73(1):162-5. doi:10.1016/j.jsurg.2015.08.011

[22]

Johnson P.C., Roberts A.D., Hire J.M., et al. The effect of instrumentation on suture tensile strength and knot pullout strength of common suture materials // Journal of Surgical Education. 2016. Vol. 73, №1. P. 162-165. doi:10.1016/j.jsurg.2015.08.011

[23]

Lazarenko VA, Lipatov VA, Lazarenko SV, et al. Ustrojstvo dlja issledovanija fiziko-mehanicheskih harakteristik shvov i shovnogo materiala, stepeni deformacii parenhimy organov. Patent RUS №184617U1. 03.07.2018. Available at: https:// rusneb.ru/catalog/000224_000128_0000184617_20181101_U1_RU/. Accessed: 2019 December 12. (In Russ).

[24]

Лазаренко В.А., Липатов В.А., Лазаренко С.В., и др. Устройство для исследования физико-механических характеристик швов и шовного материала, степени деформации паренхимы органов. Патент РФ на изобретение №184617U1. 03.07.2018. Бюл. №31. Доступно по: https:// rusneb.ru/catalog/000224_000128_0000184617_20181101_U1_RU/. Ссылка активна на 12.12.2019.

RIGHTS & PERMISSIONS

Lipatov V.A., Severinov D.A., Denisov A.A., Lazarenko S.V., Grigor’yev N.N.

AI Summary AI Mindmap
PDF (483KB)

82

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/