Cardiac blood vessels and irreversible electroporation: findings from pulsed field ablation

Ikeotunye Royal Chinyere , Shumpei Mori , Mathew D. Hutchinson

Vessel Plus ›› 2024, Vol. 8 ›› Issue (1) : 7

PDF
Vessel Plus ›› 2024, Vol. 8 ›› Issue (1) :7 DOI: 10.20517/2574-1209.2023.80
Review

Cardiac blood vessels and irreversible electroporation: findings from pulsed field ablation

Author information +
History +
PDF

Abstract

The clinical use of irreversible electroporation in invasive cardiac laboratories, termed pulsed field ablation (PFA), is gaining early enthusiasm among electrophysiologists for the management of both atrial and ventricular arrhythmogenic substrates. Though electroporation is regularly employed in other branches of science and medicine, concerns regarding the acute and permanent vascular effects of PFA remain. This comprehensive review aims to summarize the preclinical and adult clinical data published to date on PFA’s effects on pulmonary veins and coronary arteries. These data will be contrasted with the incidences of iatrogenic pulmonary vein stenosis and coronary artery injury secondary to thermal cardiac ablation modalities, namely radiofrequency energy, laser energy, and liquid nitrogen-based cryoablation.

Keywords

Spasm / stenosis / coronary / pulmonary / electrophysiology / arrhythmia / safety / catheter

Cite this article

Download citation ▾
Ikeotunye Royal Chinyere, Shumpei Mori, Mathew D. Hutchinson. Cardiac blood vessels and irreversible electroporation: findings from pulsed field ablation. Vessel Plus, 2024, 8(1): 7 DOI:10.20517/2574-1209.2023.80

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Lavee J,Mikus P.A novel nonthermal energy source for surgical epicardial atrial ablation: irreversible electroporation.Heart Surg Forum2007;10:E162-7

[2]

Jones JL,Balasky G.Microlesion formation in myocardial cells by high-intensity electric field stimulation.Am J Physiol1987;253:H480-6

[3]

Dev SB.Electrochemotherapy - a novel method of cancer treatment.Cancer Treat Rev1994;20:105-15

[4]

Bakhtiari S,Candas M.Changes in electrical capacitance of cell membrane reflect drug partitioning-induced alterations in lipid bilayer.Micromachines2023;14:316 PMCID:PMC9961635

[5]

Napotnik T, Polajžer T, Miklavčič D. Cell death due to electroporation - a review.Bioelectrochemistry2021;141:107871

[6]

Aycock KN,Davalos RV.A comparative modeling study of thermal mitigation strategies in irreversible electroporation treatments.J Heat Transfer2022;144:031206 PMCID:PMC8823459

[7]

Dunki-Jacobs EM,Martin RC 2nd.Evaluation of thermal injury to liver, pancreas and kidney during irreversible electroporation in an in vivo experimental model.Br J Surg2014;101:1113-21

[8]

Ruwald MH,Hansen ML,Worck R.Utility of high-density 3D-bipolar voltage map after pulmonary vein isolation by pulsed-field ablation.JACC Clin Electrophysiol2023;9:588-90

[9]

Lafarge EJ,Schroder AP,Behrends JC.Activation energy for pore opening in lipid membranes under an electric field.Proc Natl Acad Sci USA2023;120:e2213112120 PMCID:PMC10089165

[10]

Guo F,Deng Q.Effects of pulsed field ablation on autonomic nervous system in paroxysmal atrial fibrillation: a pilot study.Heart Rhythm2023;20:329-38

[11]

Musikantow DR,Petru J.Pulsed field ablation to treat atrial fibrillation: autonomic nervous system effects.JACC Clin Electrophysiol2023;9:481-93

[12]

Stojadinović P,Peichl P.Autonomic changes are more durable after radiofrequency than pulsed electric field pulmonary vein ablation.JACC Clin Electrophysiol2022;8:895-904

[13]

Howard B,Tzou WS.Effects of electrode-tissue proximity on cardiac lesion formation using pulsed field ablation.Circ Arrhythm Electrophysiol2022;15:e011110 PMCID:PMC9584049

[14]

Belalcazar A.Safety and efficacy aspects of pulsed field ablation catheters as a function of electrode proximity to blood and energy delivery method.2021;2:560-9 PMCID:PMC8703144

[15]

Mattison L,Tarakji KG.Effect of contact force on pulsed field ablation lesions in porcine cardiac tissue.J Cardiovasc Electrophysiol2023;34:693-9

[16]

Kawamura I,Santos-Gallego CG.Electrophysiology, pathology, and imaging of pulsed field ablation of scarred and healthy ventricles in swine.Circ Arrhythm Electrophysiol2023;16:e011369

[17]

Verma A,Haines DE.First-in-human experience and acute procedural outcomes using a novel pulsed field ablation system: the PULSED AF pilot trial.Circ Arrhythm Electrophysiol2022;15:e010168 PMCID:PMC8772438

[18]

González-Suárez A,O'Brien B.In silico modelling to assess the electrical and thermal disturbance provoked by a metal intracoronary stent during epicardial pulsed electric field ablation.J Cardiovasc Dev Dis2022;9:458 PMCID:PMC9784210

[19]

Reddy VY,Natale A.ADVENT InvestigatorsPulsed field or conventional thermal ablation for paroxysmal atrial fibrillation.N Engl J Med2023;389:1660-71

[20]

Iasiello M,Bianco N.The porous media theory applied to radiofrequency catheter ablation.HFF2020;30:2669-81

[21]

Iasiello M,Bianco N.Effects of pulsed radiofrequency source on cardiac ablation.Bioengineering2023;10:227 PMCID:PMC9952521

[22]

Pérez JJ,Berjano E.Computer modeling of radiofrequency cardiac ablation including heartbeat-induced electrode displacement.Comput Biol Med2022;144:105346

[23]

Stöckigt F,Andrié R.Atrioesophageal fistula after cryoballoon pulmonary vein isolation.J Cardiovasc Electrophysiol2012;23:1254-7

[24]

Restrepo AJ.62 - Computed Tomography for Electrophysiology. In: Douglas P. Zipes, José Jalife, William G. Stevenson, Editors. Cardiac electrophysiology: from cell to bedside. Amsterdam: Elsevier; 2018. pp. 587-600.

[25]

Ahero A,Breitenstein A,Kucher N.Partially reversible lung consolidation after revascularization of a total occlusion of both left pulmonary veins following ablation of atrial fibrillation: a case report.Eur Heart J Case Rep2023;7:ytad057 PMCID:PMC9942540

[26]

Vanderlaan RD.Pulmonary vein stenosis: incremental knowledge gains to improve outcomes.Children2021;8:481 PMCID:PMC8229191

[27]

Samuel M,Mongeon FP.Pulmonary vein stenosis after atrial fibrillation ablation: insights from the ADVICE trial.Can J Cardiol2020;36:1965-74

[28]

Teunissen C,Hassink RJ.Incidence of pulmonary vein stenosis after radiofrequency catheter ablation of atrial fibrillation.JACC Clin Electrophysiol2017;3:589-98

[29]

Kawamura I,Wang BJ.Pulsed field ablation of the porcine ventricle using a focal lattice-tip catheter.Circ Arrhythm Electrophysiol2022;15:e011120 PMCID:PMC9794124

[30]

Roberts-Thomson KC,Seiler J.Coronary artery injury due to catheter ablation in adults: presentations and outcomes.Circulation2009;120:1465-73

[31]

Yue-Chun L,Xue-Qiang G.Chronic left coronary artery stenosis after radiofrequency ablation of idiopathic premature ventricular contraction originating from left coronary sinus cusp.Circ Arrhythm Electrophysiol2016;9:e004353

[32]

Caldwell JC,Garratt CJ.Right coronary artery damage during cavotricuspid isthmus ablation.Pacing Clin Electrophysiol2010;33:e110-3

[33]

Stavrakis S,Nakagawa H.Risk of coronary artery injury with radiofrequency ablation and cryoablation of epicardial posteroseptal accessory pathways within the coronary venous system.Circ Arrhythm Electrophysiol2014;7:113-9

[34]

Li FH,Zhang Q.The efficacy and safety of pulsed-field ablation in para-Hisian paroxysmal supraventricular tachycardia: first-in-human pilot trial.Eur Heart J2023;44:ehac779.026

[35]

Adeliño R,El Bouazzaoui R,Combes N.Pulsed-field ablation of recurrent right atrial tachycardia: expanding the use of electroporation beyond atrial fibrillation.Europace2023;25:1512 PMCID:PMC10105872

[36]

Phlips T,Antole N,Vijgen J.Pulsed field ablation using a focal contact force catheter allowed successful ablation of a focal right atrial tachycardia in the proximity of the phrenic nerve.HeartRhythm Case Rep2023;9:434-6 PMCID:PMC10363427

[37]

Winkelmann S,Wuerger T.Safety of pulsed-field ablation in patients with cardiac implantable electronic devices. A single-center pilot study.EP Europace2022;24:euac053.234

[38]

Reddy VY,Gerstenfeld EP.A randomized controlled trial of pulsed field ablation versus standard-of-care ablation for paroxysmal atrial fibrillation: the ADVENT trial rationale and design.Heart Rhythm O22023;4:317-28 PMCID:PMC10264259

[39]

Fender EA,Hodge DO.Severe pulmonary vein stenosis resulting from ablation for atrial fibrillation: presentation, management, and clinical outcomes.Circulation2016;134:1812-21

[40]

Meckes D,Fong I,Sanders P.Pulsed-field ablation: computational modeling of electric fields for lesion depth analysis.Heart Rhythm O22022;3:433-40 PMCID:PMC9463712

[41]

Gómez-Barea M,Ivorra A.A computational comparison of radiofrequency and pulsed field ablation in terms of lesion morphology in the cardiac chamber.Sci Rep2022;12:16144 PMCID:PMC9515184

[42]

Zang L,Ji X,Yan S.Comparative analysis of temperature rise between convective heat transfer method and computational fluid dynamics method in an anatomy-based left atrium model during pulsed field ablation: a computational study.J Cardiovasc Dev Dis2023;10:56 PMCID:PMC9968112

[43]

García-Sánchez T,Jorge E.Parametric study of pulsed field ablation with biphasic waveforms in an in vivo heart model: the role of frequency.Circ Arrhythm Electrophysiol2022;15:e010992

[44]

van Driel VJ,van Wessel H.Pulmonary vein stenosis after catheter ablation: electroporation versus radiofrequency.Circ Arrhythm Electrophysiol2014;7:734-8

[45]

Koruth J,Iwasawa J.Preclinical evaluation of pulsed field ablation: electrophysiological and histological assessment of thoracic vein isolation.Circ Arrhythm Electrophysiol2019;12:e007781 PMCID:PMC6924932

[46]

Koruth JS,Kawamura I.Focal pulsed field ablation for pulmonary vein isolation and linear atrial lesions: a preclinical assessment of safety and durability.Circ Arrhythm Electrophysiol2020;13:e008716

[47]

Ye X,Yin H.Study on optimal parameter and target for pulsed-field ablation of atrial fibrillation.Front Cardiovasc Med2021;8:690092 PMCID:PMC8490619

[48]

Hsu JC,Banker R.In vivo porcine characterization of atrial lesion safety and efficacy utilizing a circular pulsed-field ablation catheter including assessment of collateral damage to adjacent tissue in supratherapeutic ablation applications.J Cardiovasc Electrophysiol2022;33:1480-8 PMCID:PMC9545022

[49]

Zhao Z,Wu B.Pulsed-field ablation using a novel ablation-mapping integrated system for pulmonary vein isolation-a preliminary animal study.J Cardiovasc Dev Dis2022;9:425 PMCID:PMC9781645

[50]

Koruth J,Dukkipati SR,Reddy VY.Preclinical assessment of the feasibility, safety and lesion durability of a novel 'single-shot' pulsed field ablation catheter for pulmonary vein isolation.Europace2023;25:1369-78 PMCID:PMC10105880

[51]

Howard B,Verma A.Reduction in pulmonary vein stenosis and collateral damage with pulsed field ablation compared with radiofrequency ablation in a canine model.Circ Arrhythm Electrophysiol2020;13:e008337 PMCID:PMC7495982

[52]

Koruth J,Kawamura I.PV isolation using a spherical array pfa catheter: preclinical assessment and comparison to radiofrequency ablation.JACC Clin Electrophysiol2023;9:652-66

[53]

Reddy VY,Jais P.Ablation of atrial fibrillation with pulsed electric fields: an ultra-rapid, tissue-selective modality for cardiac ablation.JACC Clin Electrophysiol2018;4:987-95

[54]

Reddy VY,Koruth JS.Pulsed field ablation for pulmonary vein isolation in atrial fibrillation.J Am Coll Cardiol2019;74:315-26

[55]

Reddy VY,Koruth J.Pulsed field ablation in patients with persistent atrial fibrillation.J Am Coll Cardiol2020;76:1068-80

[56]

Kuroki K,Eggert C.Ostial dimensional changes after pulmonary vein isolation: Pulsed field ablation vs radiofrequency ablation.Heart Rhythm2020;17:1528-35

[57]

Reddy VY,Neuzil P.Pulsed field ablation of paroxysmal atrial fibrillation: 1-year outcomes of IMPULSE, PEFCAT, and PEFCAT II.JACC Clin Electrophysiol2021;7:614-27

[58]

Chen S,Bordignon S.Pulsed field ablation-based pulmonary vein isolation in atrial fibrillation patients with cardiac implantable electronic devices: practical approach and device interrogation (PFA in CIEDs).J Interv Card Electrophysiol2023;66:1929-38 PMCID:PMC10570236

[59]

Gunawardene MA,Jularic M.Pulsed field ablation in patients with complex consecutive atrial tachycardia in conjunction with ultra-high density mapping: Proof of concept.J Cardiovasc Electrophysiol2022;33:2431-43

[60]

Turagam MK,Petru J.PV isolation using a spherical array PFA catheter: application repetition and lesion durability (PULSE-EU Study).JACC Clin Electrophysiol2023;9:638-48

[61]

Tohoku S,Bordignon S.Findings from repeat ablation using high-density mapping after pulmonary vein isolation with pulsed field ablation.Europace2023;25:433-40 PMCID:PMC9935020

[62]

Duytschaever M,Grimaldi M.inspIRE Trial InvestigatorsParoxysmal atrial fibrillation ablation using a novel variable-loop biphasic pulsed field ablation catheter integrated with a 3-dimensional mapping system: 1-year outcomes of the multicenter inspIRE study.Circ Arrhythm Electrophysiol2023;16:e011780 PMCID:PMC10026968

[63]

Ekanem E,Schmidt B.MANIFEST-PF CooperativeMulti-national survey on the methods, efficacy, and safety on the post-approval clinical use of pulsed field ablation (MANIFEST-PF).Europace2022;24:1256-66 PMCID:PMC9435639

[64]

Repp ML.Opportunities and challenges in catheter-based irreversible electroporation for ventricular tachycardia.Pathophysiology2024;31:32-43

[65]

Yavin HD,Sroubek J,Zilberman I.Pulsed-field ablation in ventricular myocardium using a focal catheter: the impact of application repetition on lesion dimensions.Circ Arrhythm Electrophysiol2021;14:e010375

[66]

Koruth JS,Iwasawa J.Endocardial ventricular pulsed field ablation: a proof-of-concept preclinical evaluation.Europace2020;22:434-9 PMCID:PMC7058968

[67]

Sandhu U,Kheiri B.In vivo pulsed-field ablation in healthy vs. chronically infarcted ventricular myocardium: biophysical and histologic characterization.Europace2023;25:1503-9 PMCID:PMC10105837

[68]

Hunter DW,Fish JM,Tandri H.In vitro cell selectivity of reversible and irreversible: electroporation in cardiac tissue.Circ Arrhythm Electrophysiol2021;14:e008817

[69]

Maor E,Leor J.The effect of irreversible electroporation on blood vessels.Technol Cancer Res Treat2007;6:307-12

[70]

Maor E,Rubinsky B.Non thermal irreversible electroporation: novel technology for vascular smooth muscle cells ablation.PLoS One2009;4:e4757 PMCID:PMC2650260

[71]

Maor E,Mitchell JJ.Vascular smooth muscle cells ablation with endovascular nonthermal irreversible electroporation.J Vasc Interv Radiol2010;21:1708-15 PMCID:PMC2966522

[72]

Phillips M,Rubinsky B.Nonthermal irreversible electroporation for tissue decellularization.J Biomech Eng2010;132:091003

[73]

Reddy VY,Funasako M.Coronary arterial spasm during pulsed field ablation to treat atrial fibrillation.Circulation2022;146:1808-19

[74]

Gunawardene MA,Jularic M.Coronary spasm during pulsed field ablation of the mitral isthmus line.JACC Clin Electrophysiol2021;7:1618-20

[75]

Wilber DJ.Pulsed-field ablation and the coronary arteries: not so simple.JACC Clin Electrophysiol2022;8:1497-9

[76]

du Pré BC,van Wessel H.Minimal coronary artery damage by myocardial electroporation ablation.Europace2013;15:144-9

[77]

Neven K,van Wessel H.Safety and feasibility of closed chest epicardial catheter ablation using electroporation.Circ Arrhythm Electrophysiol2014 7:913-9.

[78]

Neven K,van Wessel H,Doevendans PA.Myocardial lesion size after epicardial electroporation catheter ablation after subxiphoid puncture.Circ Arrhythm Electrophysiol2014;7:728-33

[79]

Neven K,van Wessel H,Doevendans PA.Epicardial linear electroporation ablation and lesion size.Heart Rhythm2014;11:1465-70

[80]

Im SI,Lee A.Pulsed field ablation of left ventricular myocardium in a swine infarct model.JACC Clin Electrophysiol2022;8:722-31

[81]

Ladejobi A,Tan N.Effects of Pulsed Electric Fields on the Coronary Arteries in Swine.Circ Arrhythm Electrophysiol2022;15:e010668

[82]

Buist TJ,Wittkampf FHM.Feasibility of linear irreversible electroporation ablation in the coronary sinus.Cardiovasc Eng Technol2023;14:60-6

[83]

Higuchi S,Stillson C.Effect of epicardial pulsed field ablation directly on coronary arteries.JACC Clin Electrophysiol2022;8:1486-96

[84]

van Zyl M,Tri JA.Bipolar electroporation across the interventricular septum: electrophysiological, imaging, and histopathological characteristics.JACC Clin Electrophysiol2022;8:1106-18

[85]

Ouss A,van der Voort P.First in human pulsed field ablation to treat scar-related ventricular tachycardia in ischemic heart disease: a case report.J Interv Card Electrophysiol2023;66:509-10

PDF

26

Accesses

0

Citation

Detail

Sections
Recommended

/