Third-Rail Insulator Failure Causes and Mitigating Practices: A Comparative Study of Multiple Case Studies in the U.S.
Behzad Rouhanizadeh , Sharareh Kermanshachi
Urban Rail Transit ›› 2020, Vol. 6 ›› Issue (4) : 205 -217.
Third-Rail Insulator Failure Causes and Mitigating Practices: A Comparative Study of Multiple Case Studies in the U.S.
Rail transit systems are one of the most important and popular types of transit systems used daily in metropolitan areas all around the world. The third rail is one of the providers of traction power in electrified rail systems, but it faces several issues, such as insulator failures. The purpose of this study is to investigate the causes of insulator failures, which have not been comprehensively studied and presented in the literature. To accomplish this objective, eight transit systems with third rails were selected to (1) investigate the characteristics of third-rail systems, (2) determine the causes of insulator failures, (3) analyze the costs associated with insulator failures, and (4) determine mitigating practices to reduce the number and cost of insulator failures. After a thorough literature review, details of eight case studies were collected from different transit agencies, and their subject matter experts were asked to complete a survey and provide input. The results revealed that a build-up of dirt was the major cause of the 17 identified causes of insulator failures; carbon dust and dirt were identified as the most present particles in third-rail systems. It was noted that transit agencies often implement multiple mitigating practices such as cleaning the insulator, performing visual inspections, and conducting regular maintenance to reduce the number and cost of insulator failures. The findings of this study will help decision-makers for transit systems make timely decisions to prevent third-rail insulator failures and adopt appropriate practices that best fit their transit system.
Third-rail system / Insulator / Failure / Mitigating strategy
| [1] |
|
| [2] |
|
| [3] |
|
| [4] |
Xu G, McGrath PB, Burns CW (1996) Accelerated environmental and electrical aging of polymer insulators. In: Proceedings of conference on electrical insulation and dielectric Phenomena-CEIDP’96, 1:404–407 |
| [5] |
|
| [6] |
|
| [7] |
|
| [8] |
|
| [9] |
Vohra A (2008) Cleaning device for electrified third rail insulators–Phase 2 (No. Transit IDEA Project 47) |
| [10] |
Ibrahem A (2017) Leakage current detection and protection for electrical railway systems. M.Sc. thesis |
| [11] |
Fourmigue JM, Noel M, Riquel G (1995) Aging of polymeric housing for HV insulators: comparison between natural and artificial testing. In: Proceedings of 1995 conference on electrical insulation and dielectric phenomena, pp 404–407 |
| [12] |
|
| [13] |
Forman KG (2013) Aluminum/stainless steel conductor technology: a case for its adoption in the US In 2013 joint rail conference. american society of mechanical engineers digital collection |
| [14] |
|
| [15] |
|
| [16] |
|
| [17] |
Ehsani M, Borsi H, Gockenbach E, Morshedian J, Bakhshandeh GR, Shayegani AA (2004) Effect of aging on dielectric behavior of outdoor polymeric insulators. In: Proceedings of the 2004 IEEE international conference on solid dielectrics, 2004. ICSD 200, 1: 312–315 |
| [18] |
Sun Y, Chen X, Jian X, Xiao Z (2019) Identification and localization method of the insulator based on three-dimensional point cloud modeling. In: Chinese control conference (CCC), pp 7051–7056 |
| [19] |
|
| [20] |
|
| [21] |
|
| [22] |
Nyamupangedengu C, Luhlanga LP, Letlape T (2007) Acoustic and HF detection of defects on porcelain pin insulators. In: IEEE power engineering society conference and exposition in Africa-PowerAfrica, pp 1–5 |
| [23] |
Cavallin A, Chandrasekar S, Montanari GC, Puletti F (2007) Inferring ceramic insulator pollution by an innovative approach resorting to PD detection. IEEE Trans Dielectr Electr Insul 14:23–29 |
| [24] |
|
| [25] |
Nekeb AS, Harid N, Haddad A (2011) Effect of UV irradiation on the leakage current of polymeric insulators. In: 2011 46th international universities’ power engineering conference (UPEC), pp 1–4 |
| [26] |
|
| [27] |
|
| [28] |
|
| [29] |
|
| [30] |
Vohra A (2004) Cleaning device for electrified third rail insulators. Transit IDEA Project Report 36 |
| [31] |
Hu Y (2001) The analysis of the pollution of network on Fab. 22th and counter measures from pollution flashover. Insul Surge Arrester, pp 4–11 |
| [32] |
|
| [33] |
|
| [34] |
|
| [35] |
|
| [36] |
|
| [37] |
|
| [38] |
Kermanshachi S, Rouhanizadeh B (2020) TCRP synthesis J-07/topic SD-05: third rail insulator failures—current state of the practice. Research Report, pp 1–74 |
/
| 〈 |
|
〉 |