Overall smoke control performance using naturally ventilated shafts in tunnel fires with multiple fire sources

Kun He , Ying Zhen Li , Haukur Ingason , Xudong Cheng

Underground Space ›› 2025, Vol. 22 ›› Issue (3) : 168 -185.

PDF (2707KB)
Underground Space ›› 2025, Vol. 22 ›› Issue (3) :168 -185. DOI: 10.1016/j.undsp.2024.10.005
Research article
research-article

Overall smoke control performance using naturally ventilated shafts in tunnel fires with multiple fire sources

Author information +
History +
PDF (2707KB)

Abstract

This study investigates the overall smoke control performance using shafts in a naturally ventilated tunnel in the case of multiple fire sources. Detailed comparisons were also made with the corresponding single fire source scenarios. The results show that the interaction between multiple fire sources affects smoke control performance, resulting in a lower smoke layer height compared to the corresponding single fire scenario. For the multiple fire sources scenarios, the smoke layer height in the fire section first decreases and then keeps stable, as the fire center spacing increases. The smoke layer height in the fire section is 20%-25% lower than that in a single fire source scenario for a given total heat release rate. The minimum smoke layer height at the adjacent non-fire tunnel section is much lower than that in the fire section due to the disturbance of the first group of shafts. For a small tunnel fire such as a car fire, the critical safety distances for firefighters and evacuees increase as the fire source spacing decreases. For a large tunnel fire such as a bus fire, the effect of fire source spacing on the critical safety distance is limited, while the shaft interval plays an important role. The fire source spacing and the number of fire sources have limited influences on the smoke spread length due to the small differences in the induced air flow velocity and overall smoke exhaust rate through shafts. When the fire sources are located under one shaft, the number of shafts required for complete smoke exhaust is the least and the total smoke spread length is the shortest. For a given fire location, the smoke spread length increases significantly with an increasing shaft interval. This study contributes to the design of natural ventilation shafts in tunnels possibly with multiple fire sources.

Keywords

Overall smoke control performance / Natural ventilation / Vertical shafts / Multiple fire sources / Tunnel fire

Cite this article

Download citation ▾
Kun He, Ying Zhen Li, Haukur Ingason, Xudong Cheng. Overall smoke control performance using naturally ventilated shafts in tunnel fires with multiple fire sources. Underground Space, 2025, 22(3): 168-185 DOI:10.1016/j.undsp.2024.10.005

登录浏览全文

4963

注册一个新账户 忘记密码

Data availability

The data that support the findings of this study are available from the corresponding author upon reasonable request.

CRediT authorship contribution statement

Kun He: Writing - original draft, Validation, Software, Investigation, Formal analysis, Data curation, Conceptualization. Ying Zhen Li: Writing - review & editing, Supervision, Project administration, Methodology, Investigation, Funding acquisition, Formal analysis, Conceptualization. Haukur Ingason: Writing - review & editing, Supervision, Resources, Methodology, Funding acquisition. Xudong Cheng: Writing - review & editing, Supervision, Resources.

Declaration of competing interest

Ying Zhen Li is an editorial board member for Underground Space and was not involved in the editorial review or the decision to publish this article. All authors declare that there are no competing interests.

Acknowledgement

This project was financially supported by the National Key Research and Development Program of China (Grant No. 2022YFC3005201), Anhui Provincial Natural Science Foundation (Grant No. 2408085QE139) and the Tunnel and Underground Safety Center. Besides, the authors would like to acknowledge China Scholarship Council for providing Kun He with the opportunity to study at RISE Research Institutes of Sweden where the work was carried out.

References

[1]

Fan, C., Ji, J., Gao, Z., Han, J., & Sun, J. (2013). Experimental study of air entrainment mode with natural ventilation using shafts in road tunnel fires. International Journal of Heat and Mass Transfer, 56, 750-757.

[2]

Fan, C., Zhang, L., Jiao, S., Yang, Z., Li, M., & Liu, X. (2018). Smoke spread characteristics inside a tunnel with natural ventilation under a strong environmental wind. Tunnelling and Underground Space Technology, 82, 99-110.

[3]

Fan, C. G., & Tang, F. (2017). Flame interaction and burning characteristics of abreast liquid fuel fires with cross wind. Experimental Thermal Fluid Science, 82, 160-165.

[4]

Guo, C., Zhang, T., Guo, Q., Yu, T., Fang, Z., & Yan, Z. (2023). Fullscale experimental study on fire characteristics induced by double fire sources in a two-lane road tunnel. Tunnelling and Underground Space Technology, 131, 104768.

[5]

Guo, Q., Zhu, H., Zhang, Y., Shen, Y., Zhang, Y., & Yan, Z. (2020a). Smoke flow in full-scale urban road tunnel fires with large crosssectional vertical shafts. Tunnelling and Underground Space Technology, 104, 103536.

[6]

Guo, Q., Zhu, H., Zhang, Y., & Yan, Z. (2020b). Theoretical and experimental studies on the fire-induced smoke flow in naturally ventilated tunnels with large cross-sectional vertical shafts. Tunnelling and Underground Space Technology, 99, 103359.

[7]

Guo, Y., Yuan, Z., Yuan, Y., Cao, X., & Zhao, P. (2021). Numerical simulation of smoke stratification in tunnel fires under longitudinal velocities. Underground Space, 6, 163-172.

[8]

He, K., Cheng, X., Li, Y. Z., Ingason, H., & Zhang, H. (2021). Experimental study on flame characteristics of double fires in a naturally ventilated tunnel: flame merging, flame tilt angle and flame height. Tunnelling and Underground Space Technology, 114, 103912.

[9]

He, K., Cheng, X., Yao, Y., Shi, L., Yang, H., & Cong, W. (2019a). Characteristics of multiple pool fires in a tunnel with natural ventilation. Journal of Hazardous Materials, 369, 261-267.

[10]

He, K., Cheng, X., Zhang, S., Yang, H., Yao, Y., Peng, M., & Cong, W. (2018). Critical roof opening longitudinal length for complete smoke exhaustion in subway tunnel fires. International Journal of Thermal Sciences, 133, 55-61.

[11]

He, K., Cheng, X., Zhang, S., Yao, Y., Peng, M., Yang, H., Cong, W., Shi, Z., & Chen, Z. (2019b). Experimental study on smoke control using wide shafts in a natural ventilated tunnel. Journal of Wind Engineering and Industrial Aerodynamics, 195, 104015.

[12]

He, K., Li, Y. Z., Ingason, H., Shi, L., & Cheng, X. (2024). Experimental study on the maximum ceiling gas temperature driven by double fires in a tunnel with natural ventilation. Tunnelling and Underground Space Technology, 144, 105550.

[13]

He, L., Xu, Z., Markert, F., Zhao, J., Liu, Q., Tao, H., Wang, Z., & Fan, C. (2020). Experimental study of heat exhaust efficiency with natural ventilation in tunnel fire: Impact of shaft height and heat release rate. Journal of Wind Engineering and Industrial Aerodynamics, 201, 104173.

[14]

Hu, L., Huo, R., & Chow, W. (2008). Studies on buoyancy-driven backlayering flow in tunnel fires. Experimental Thermal and Fluid Science, 32, 1468-1483.

[15]

Ingason, H., & Li, Y. Z. (2017). Spilled liquid fires in tunnels. Fire Safety Journal, 91, 399-406.

[16]

Ingason, H., Li, Y. Z., & Lönnermark, A. (2014). Tunnel fire dynamics. New York: Springer.

[17]

Ji, J., Gao, Z., Fan, C., & Sun, J. (2013). Large Eddy Simulation of stack effect on natural smoke exhausting effect in urban road tunnel fires. International Journal of Heat and Mass Transfer, 66, 531-542.

[18]

Ji, J., Wan, H., Gao, Z., Fu, Y., Sun, J., Zhang, Y., Li, K., & Hostikka, S. (2016). Experimental study on flame merging behaviors from two pool fires along the longitudinal centerline of model tunnel with natural ventilation. Combustion and Flame, 173, 307-318.

[19]

Karlsson, B., & Quintiere, J. G. (2000). Enclosure fire dynamics. CRC Press.

[20]

Kashef, A., Yuan, Z., & Lei, B. (2013). Ceiling temperature distribution and smoke diffusion in tunnel fires with natural ventilation. Fire Safety Journal, 62, 249-255.

[21]

Li, J. S., & Chow, W. (2003). Numerical studies on performance evaluation of tunnel ventilation safety systems. Tunnelling and Underground Space Technology, 18, 435-452.

[22]

Li, Y. Z., & Ingason, H. (2018). Overview of research on fire safety in underground road and railway tunnels. Tunnelling and Underground Space Technology, 81, 568-589.

[23]

Liu, N., Liu, Q., Deng, Z., Kohyu, S., & Zhu, J. (2007). Burn-out time data analysis on interaction effects among multiple fires in fire arrays. Proceedings of the Combustion Institute, 31, 2589-2597.

[24]

Liu, N., Liu, Q., Lozano, J. S., Shu, L., Zhang, L., Zhu, J., Deng, Z., & Satoh, K. (2009). Global burning rate of square fire arrays: experimental correlation and interpretation. Proceedings of the Combustion Institute, 32, 2519-2526.

[25]

Loennermark, A., & Ingason, H. (2006). Fire spread and flame length in large-scale tunnel fires. Fire Technology, 42, 283-302.

[26]

Ma, T., & Quintiere, J. (2003). Numerical simulation of axi-symmetric fire plumes: accuracy and limitations. Fire Safety Journal, 38, 467-492.

[27]

McGrattan, K., Hostikka, S., McDermott, R., Floyd, J., Weinschenk, C., & Overholt, K. (2013). Fire dynamics simulator technical reference guide volume 1:mathematical model. NIST Special Publication, 1018, 175.

[28]

Meng, N. (2023). Experimental study on flame merging behaviors and smoke backlayering length of two fires in a longitudinally ventilated tunnel. Tunnelling and Underground Space Technology, 137, 105147.

[29]

Oka, Y., Oka, H., & Imazeki, O. (2016). Ceiling-jet thickness and vertical distribution along flat-ceilinged horizontal tunnel with natural ventilation. Tunnelling and Underground Space Technology, 53, 68-77.

[30]

Sun, C., Weng, M., Liu, F., & Ling, K. (2024). Study on the smoke flow characteristics in inclined tunnel with an upstream shaft under natural ventilation. Tunnelling and Underground Space Technology, 149, 105806.

[31]

Tanaka, F., Kawabata, N., & Ura, F. (2016). Effects of a transverse external wind on natural ventilation during fires in shallow urban road tunnels with roof openings. Fire Safety Journal, 79, 20-36.

[32]

Tanaka, F., Kawabata, N., & Ura, F. (2017). Smoke spreading characteristics during a fire in a shallow urban road tunnel with roof openings under a longitudinal external wind blowing. Fire Safety Journal, 90, 156-168.

[33]

Tang, F., Deng, L., Meng, N., Mcnamee, M., Van Hees, P., & Hu, L. (2020). Critical longitudinal ventilation velocity for smoke control in a tunnel induced by two nearby fires of various distances: Experiments and a revisited model. Tunnelling and Underground Space Technology, 105, 103559.

[34]

Tilley, N., Rauwoens, P., & Merci, B. (2011). Verification of the accuracy of CFD simulations in small-scale tunnel and atrium fire configurations. Fire Safety Journal, 46, 186-193.

[35]

Tong, Y., Zhai, J., Wang, C., Zhou, B., & Niu, X. (2016). Possibility of using roof openings for natural ventilation in a shallow urban road tunnel. Tunnelling and Underground Space Technology, 54, 92-101.

[36]

Tsai, K.-C., Chen, H.-H., & Lee, S.-K. (2010). Critical ventilation velocity for multi-source tunnel fires. Journal of Wind Engineering and Industrial Aerodynamics, 98, 650-660.

[37]

Wahlqvist, J., & Van Hees, P. (2013). Validation of FDS for large-scale well-confined mechanically ventilated fire scenarios with emphasis on predicting ventilation system behavior. Fire Safety Journal, 62, 102-114.

[38]

Wan, H., Xiao, Y., Wei, S., & Zhang, Y. (2022). Performance of ceiling jet induced by dual unequal strong plumes in a naturally ventilated tunnel. Applied Thermal Engineering, 211, 118447.

[39]

Wang, J., Song, Y., Fan, Y., Jiang, X., & Lu, K. (2023). Reduced pressure effect on smoke layer plug-holing behavior of tunnel fires with a naturally ventilated vertical shaft. Fire Technology, 60(2), 1379-1401.

[40]

Wang, Y., Jiang, J., & Zhu, D. (2009). Full-scale experiment research and theoretical study for fires in tunnels with roof openings. Fire Safety Journal, 44, 339-348.

[41]

Wang, Y. F., Sun, X. F., Liu, S., Yan, P. N., Qin, T., & Zhang, B. (2016). Simulation of back-layering length in tunnel fire with vertical shafts. Applied Thermal Engineering, 109, 344-350.

[42]

Yan, T., MingHeng, S., YanFeng, G., & JiaPeng, H. (2009). Full-scale experimental study on smoke flow in natural ventilation road tunnel fires with shafts. Tunnelling and Underground Space Technology, 24, 627-633.

[43]

Yao, Y., Li, Y. Z., Ingason, H., & Cheng, X. (2019). Numerical study on overall smoke control using naturally ventilated shafts during fires in a road tunnel. International Journal of Thermal Sciences, 140, 491-504.

[44]

Yuan, Z., Lei, B., & Kashef, A. (2015). Experimental and theoretical study for tunnel fires with natural ventilation. Fire Technology, 51, 691-706.

[45]

Zhang, S., He, K., Yao, Y., Peng, M., Yang, H., Wang, J., & Cheng, X. (2018). Investigation on the critical shaft height of plug-holing in the natural ventilated tunnel fire. International Journal of Thermal Sciences, 132, 517-533.

[46]

Zhang, S., Shi, L., Wang, J., Li, X., Han, Y., He, K., & Cheng, X. (2019). Critical ventilation velocity of two fire sources with different separating distances in road tunnel. Journal of Fire Sciences, 37, 320-339.

[47]

Zhang, Y., Xing, S., Chen, R., Chen, L., Li, T., & Mao, P. (2020). Experimental study on maximum temperature beneath tunnel ceiling under the condition of double fire sources. Tunnelling and Underground Space Technology, 106, 103624.

[48]

Zhao, J., Cui, X., Yao, Y., Yang, R., & Chen, C. (2022). The burning process and temperature profile of double fires in a tunnel: an experimental study. Tunnelling and Underground Space Technology, 125, 104500.

[49]

Zhao, P., Chen, T., Yuan, Z., Xie, Y., & Yu, N. (2020). Critical shaft height for complete smoke exhaustion during fire at the worst longitudinal fire location in tunnels with natural ventilation. Fire Safety Journal, 116, 103207.

[50]

Zhao, S., Li, Y. Z., Ingason, H., & Liu, F. (2019). A theoretical and experimental study on the buoyancy-driven smoke flow in a tunnel with vertical shafts. International Journal of Thermal Sciences, 141, 33-46.

[51]

Zhao, X., Chi, J., Luo, H., Zhou, R., Hao, M., & Jiang, J. (2024). Effect of unpowered ventilation caps and shaft parameters on fire smoke spread in the natural ventilation tunnel with shafts. Journal of Building Engineering, 87, 109086.

PDF (2707KB)

47

Accesses

0

Citation

Detail

Sections
Recommended

/