Wearable and implantable aptamer sensors for physiological monitoring

Hak Beom Lee , Daeho Lee , Seung Hwan Ko

Soft Science ›› 2026, Vol. 6 ›› Issue (2) : 46

PDF
Soft Science ›› 2026, Vol. 6 ›› Issue (2) :46 DOI: 10.20517/ss.2025.149
Review Article
Wearable and implantable aptamer sensors for physiological monitoring
Author information +
History +
PDF

Abstract

The transition from reactive healthcare to proactive precision medicine necessitates technologies capable of real-time, continuous monitoring of physiological biomarkers. While enzymatic sensors have paved the way for metabolic tracking, they are intrinsically restricted to a narrow spectrum of redox-active analytes and often suffer from limited stability in complex biological environments. In contrast, electrochemical aptamer-based (E-AB) sensors have emerged as a revolutionary platform, offering a universal, reagent-free sensing mechanism driven by binding-induced conformational changes, independent of the target’s chemical reactivity. This review provides a comprehensive analysis of the technological trajectory of E-AB sensors across the physiological continuum of biofluids: blood, interstitial fluid (ISF), and sweat. We critically examine distinct applications ranging from implantable wires for intravascular therapeutic drug monitoring and microneedle arrays for minimally invasive ISF analysis to wearable devices for non-invasive sweat sensing. A central theme of this work is the pivotal role of “soft material” strategies in facilitating the seamless integration of rigid electronics with soft biological tissues. We highlight how functional materials - including anti-fouling coatings, hydrogel interfaces, and flexible porous nanocomposites - bridge mechanical and chemical mismatches to mitigate biofouling and ensure stable, long-term bio-interfaces. Finally, we outline the remaining hurdles for clinical translation, discussing strategies to achieve ultra-sensitivity, establish calibration-free methodologies, and integrate artificial intelligence (AI) for intelligent data processing, ultimately aiming for ubiquitous personalized healthcare.

Keywords

Electrochemical aptamer-based sensor / biofluid monitoring / soft materials / wearable biosensors / continuous monitoring

Cite this article

Download citation ▾
Hak Beom Lee, Daeho Lee, Seung Hwan Ko. Wearable and implantable aptamer sensors for physiological monitoring. Soft Science, 2026, 6 (2) : 46 DOI:10.20517/ss.2025.149

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Suami H.,Scaglioni M.. Anatomy of the lymphatic system and the lymphosome concept with reference to lymphedema Semin. Plast. Surg. 2018 32 005 11 PMC5891651

[2]

Ono S.,Egawa G.,Kabashima K.. Regulation of blood vascular permeability in the skin Inflamm. Regener. 2017 37 11 PMC5725833

[3]

Vermeer B. J.,Reman F. C.,Van Gent C. M.. The determination of lipids and proteins in suction blister fluid J. Investig. Dermatol. 1979 73 303 5

[4]

Broza Y. Y.,Zhou X.,Yuan M..et al. Disease detection with molecular biomarkers: from chemistry of body fluids to nature-inspired chemical sensors Chem. Rev. 2019 119 11761 817

[5]

Crowley E.,Di Nicolantonio F.,Loupakis F.,Bardelli A.. Liquid biopsy: monitoring cancer-genetics in the blood Nat. Rev. Clin. Oncol. 2013 10 472 84

[6]

Alix-panabières C.,Pantel K.. Clinical applications of circulating tumor cells and circulating tumor DNA as liquid biopsy Cancer Discovery 2016 6 479 91

[7]

Sturgeon C. M.,Duffy M. J.,Stenman U..et al. National academy of clinical biochemistry laboratory medicine practice guidelines for use of tumor markers in testicular, prostate, colorectal, breast, and ovarian cancers Clin. Chem. 2008 54 e11 79

[8]

Ludwig J. A.,Weinstein J. N.. Biomarkers in cancer staging, prognosis and treatment selection Nat. Rev. Cancer 2005 5 845 56

[9]

Su J.,Chen S.,Dou Y..et al. Smartphone-based electrochemical biosensors for directly detecting serum-derived exosomes and monitoring their secretion Anal. Chem. 2022 94 3235 44

[10]

Wu A. H.,Apple F. S.,Gibler W. B.,Jesse R. L.,Warshaw M. M.,Valdes R.. National academy of clinical biochemistry standards of laboratory practice: recommendations for the use of cardiac markers in coronary artery diseases Clin. Chem. 1999 45 1104 21

[11]

Mahato K.,Wang J.. Electrochemical sensors: from the bench to the skin Sensor. Actuat. B-Chem. 2021 344 130178

[12]

Zhou J. Z.,Kane S.,Ramsey C..et al. Comparison of early- and late-stage breast and colorectal cancer diagnoses during vs before the COVID-19 pandemic JAMA Netw. Open 2022 5 e2148581 PMC8848202

[13]

Renard E.. Implantable continuous glucose sensors Curr. Diabetes Rev. 2008 4 169 74

[14]

Ward W. K.,House J. L.,Birck J.,Anderson E. M.,Jansen L. B.. A wire-based dual-analyte sensor for glucose and lactate: in vitro and in vivo evaluation Diabetes Technol. The. 2004 6 389 401

[15]

Chergui K.,Suaud-Chagny M.,Gonon F.. Nonlinear relationship between impulse flow, dopamine release and dopamine elimination in the rat brain in vivo Neuroscience 1994 62 641 5

[16]

Kraft J.,Osterhaus G.,Ortiz A.,Garris P.,Johnson M.. In vivo dopamine release and uptake impairments in rats treated with 3-nitropropionic acid Neuroscience 2009 161 940 9

[17]

Zhang J.,Jaquins-Gerstl A.,Nesbitt K. M.,Rutan S. C.,Michael A. C.,Weber S. G.. In vivo monitoring of serotonin in the striatum of freely moving rats with one minute temporal resolution by online microdialysis-capillary high-performance liquid chromatography at elevated temperature and pressure Anal. Chem. 2013 85 9889 97

[18]

Wassum K. M.,Tolosa V. M.,Tseng T. C.,Balleine B. W.,Monbouquette H. G.,Maidment N. T.. Transient extracellular glutamate events in the basolateral amygdala track reward-seeking actions J. Neurosci. 2012 32 2734 46

[19]

Sarter M.,Kim Y.. Interpreting chemical neurotransmission in vivo: techniques, time scales, and theories ACS Chem. Neurosci. 2014 6 8 10

[20]

Gaster R. S.,Hall D. A.,Nielsen C. H..et al. Matrix-insensitive protein assays push the limits of biosensors in medicine Nat. Med. 2009 15 1327 32 PMC4165514

[21]

Plaxco K. W.,Soh H. T.. Switch-based biosensors: a new approach towards real-time, in vivo molecular detection Trends Biotechnol. 2011 29 1 5 PMC3010506

[22]

Couture M.,Zhao S. S.,Masson J.. Modern surface plasmon resonance for bioanalytics and biophysics Phys. Chem. Chem. Phys. 2013 15 11190 216

[23]

Marsh Z. M.,Lantz K. A.,Stefik M.. QCM detection of molecule-nanoparticle interactions for ligand shells of varying morphology Nanoscale 2018 10 19107 16

[24]

Vaisocherová H.,Brynda E.,Homola J.. Functionalizable low-fouling coatings for label-free biosensing in complex biological media: advances and applications Anal. Bioanal. Chem. 2015 407 3927 53

[25]

Breault-turcot J.,Masson J.. Microdialysis SPR: diffusion-gated sensing in blood Chem. Sci. 2015 6 4247 54 PMC5707466

[26]

Arroyo-currás N.,Somerson J.,Vieira P. A.,Ploense K. L.,Kippin T. E.,Plaxco K. W.. Real-time measurement of small molecules directly in awake, ambulatory animals Proc. Natl. Acad. Sci. U.S.A. 2017 114 645 50 PMC5278471

[27]

White R. J.,Phares N.,Lubin A. A.,Xiao Y.,Plaxco K. W.. Optimization of electrochemical aptamer-based sensors via optimization of probe packing density and surface chemistry Langmuir 2008 24 10513 8 PMC2674396

[28]

Dauphin-ducharme P.,Yang K.,Arroyo-currás N..et al. Electrochemical aptamer-based sensors for improved therapeutic drug monitoring and high-precision, feedback-controlled drug delivery ACS Sens. 2019 4 2832 7 PMC6886665

[29]

Idili A.,Arroyo-currás N.,Ploense K. L..et al. Seconds-resolved pharmacokinetic measurements of the chemotherapeutic irinotecan in situ in the living body Chem. Sci. 2019 10 8164 70

[30]

Swensen J. S.,Xiao Y.,Ferguson B. S..et al. Continuous, real-time monitoring of cocaine in undiluted blood serum via a microfluidic, electrochemical aptamer-based sensor J. Am. Chem. Soc. 2009 131 4262 6 PMC2715559

[31]

Parolo C.,Idili A.,Ortega G..et al. Real-time monitoring of a protein biomarker ACS Sens. 2020 5 1877 81 PMC8088336

[32]

Liu Y.,Kwa T.,Revzin A.. Simultaneous detection of cell-secreted TNF-α and IFN-γ using micropatterned aptamer-modified electrodes Biomaterials 2012 33 7347 55 PMC3863689

[33]

Mayer M. D.,Lai R. Y.. Effects of redox label location on the performance of an electrochemical aptamer-based tumor necrosis factor-alpha sensor Talanta 2018 189 585 91

[34]

Idili A.,Gerson J.,Parolo C.,Kippin T.,Plaxco K. W.. An electrochemical aptamer-based sensor for the rapid and convenient measurement of l-tryptophan Anal. Bioanal. Chem. 2019 411 4629 35 PMC6612299

[35]

Idili A.,Parolo C.,Ortega G.,Plaxco K. W.. Calibration-free measurement of phenylalanine levels in the blood using an electrochemical aptamer-based sensor suitable for point-of-care applications ACS Sens. 2019 4 3227 33 PMC8097980

[36]

Arroyo-Currás N.,Dauphin-Ducharme P.,Ortega G.,Ploense K. L.,Kippin T. E.,Plaxco K. W.. Subsecond-resolved molecular measurements in the living body using chronoamperometrically interrogated aptamer-based sensors ACS Sens. 2017 3 360 6

[37]

Arroyo-currás N.,Ortega G.,Copp D. A..et al. High-precision control of plasma drug levels using feedback-controlled dosing ACS Pharmacol. Transl. Sci. 2018 1 110 8 PMC7088981

[38]

Anitha K.,Posinasetty B.,Naveen Kumari K..et al. Liquid biopsy for precision diagnostics and therapeutics Clin. Chim. Acta 2024 554 117746

[39]

Zhou Y.,Tao L.,Qiu J..et al. Tumor biomarkers for diagnosis, prognosis and targeted therapy Sig. Transduct. Target. Ther. 2024 9 132 PMC11102923

[40]

Yu M.,Tyson C.,Limburg P. J.,Beer T. M.. A flexible quantitative framework to assess the potential contribution of early cancer detection to improved cancer survival J. Clin. Oncol. 2023 41 e22508

[41]

Childs A.,Mayol B.,Lasalde-Ramírez J. A.,Song Y.,Sempionatto J. R.,Gao W.. Diving into sweat: advances, challenges, and future directions in wearable sweat sensing ACS Nano 2024 18 24605 16 PMC12129723

[42]

Davis N.,Heikenfeld J.,Milla C.,Javey A.. The challenges and promise of sweat sensing Nat. Biotechnol. 2024 42 860 71

[43]

Heikenfeld J.,Jajack A.,Feldman B..et al. Accessing analytes in biofluids for peripheral biochemical monitoring Nat. Biotechnol. 2019 37 407 19

[44]

Tran B. Q.,Miller P. R.,Taylor R. M..et al. Proteomic characterization of dermal interstitial fluid extracted using a novel microneedle-assisted technique J. Proteome Res. 2017 17 479 85

[45]

Taylor R. M.,Miller P. R.,Ebrahimi P.,Polsky R.,Baca J. T.. Minimally-invasive, microneedle-array extraction of interstitial fluid for comprehensive biomedical applications: transcriptomics, proteomics, metabolomics, exosome research, and biomarker identification Lab. Anim. 2018 52 526 30

[46]

Miller P. R.,Taylor R. M.,Tran B. Q..et al. Extraction and biomolecular analysis of dermal interstitial fluid collected with hollow microneedles Commun. Biol. 2018 1 173 PMC6197253

[47]

Davis M. J.,Rahbar E.,Gashev A. A.,Zawieja D. C.,Moore J. E.. Determinants of valve gating in collecting lymphatic vessels from rat mesentery Am. J. Physiol.-Heart. C. 2011 301 H48 60 PMC3129915

[48]

Mendoza E.,Schmid-Scho¨nbein G. W.. A model for mechanics of primary lymphatic valves J. Biomech. Eng. 2003 125 407 14

[49]

Bendayan M.. Morphological and cytochemical aspects of capillary permeability Microsc. Res. Tech. 2002 57 327 49

[50]

Vink H.,Duling B. R.. Capillary endothelial surface layer selectively reduces plasma solute distribution volume Am. J. Physiol.-Heart. C. 2000 278 H285 9

[51]

Michel C. C.,Curry F. E.. Microvascular permeability Physiol. Rev. 1999 79 703 61

[52]

Tuma P. L.,Hubbard A. L.. Transcytosis: crossing cellular barriers Physiol. Rev. 2003 83 871 932

[53]

Geyer P. E.,Holdt L. M.,Teupser D.,Mann M.. Revisiting biomarker discovery by plasma proteomics Mol. Syst. Biol. 2017 13 MSB156297

[54]

Kasemo B.,Gold J.. Implant surfaces and interface processes Adv. Dent. Res. 1999 13 8 20

[55]

Zhang Z.,Zhang M.,Chen S.,Horbett T. A.,Ratner B. D.,Jiang S.. Blood compatibility of surfaces with superlow protein adsorption Biomaterials 2008 29 4285 91

[56]

Anderson N. L.,Anderson N. G.. The human plasma proteome Mol. Cell. Proteomics 2002 1 845 67

[57]

Anderson J. M.. Biological responses to materials Annu. Rev. Mater. Res. 2001 31 81 110

[58]

Hower J. C.,Bernards M. T.,Chen S.,Tsao H.,Sheng Y.,Jiang S.. Hydration of “nonfouling” functional groups J. Phys. Chem. B. 2008 113 197 201

[59]

Lavery K. S.,Rhodes C.,Mcgraw A.,Eppihimer M. J.. Anti-thrombotic technologies for medical devices Adv. Drug Delivery Rev. 2017 112 2 11

[60]

Jaffer I. H.,Weitz J. I.. The blood compatibility challenge. Part 1: blood-contacting medical devices: the scope of the problem Acta Biomater. 2019 94 2 10

[61]

Wallace A.,Albadawi H.,Patel N..et al. Anti-fouling strategies for central venous catheters Cardiovasc. Diagn. Ther. 2017 7 Suppl, S246-57. PMC5778515

[62]

Wilson C. J.,Clegg R. E.,Leavesley D. I.,Pearcy M. J.. Mediation of biomaterial-cell interactions by adsorbed proteins: a review Tissue Eng. 2005 11 1 18

[63]

Singha P.,Locklin J.,Handa H.. A review of the recent advances in antimicrobial coatings for urinary catheters Acta Biomater. 2017 50 20 40 PMC5316300

[64]

Gupta P.,Sarkar S.,Das B.,Bhattacharjee S.,Tribedi P.. Biofilm, pathogenesis and prevention - a journey to break the wall: a review Arch. Microbiol. 2015 198 1 15

[65]

Plachouras D.,Lepape A.,Suetens C.. ECDC definitions and methods for the surveillance of healthcare-associated infections in intensive care units Intensive Care Med. 2018 44 2216 8 PMC6280825

[66]

Kostakioti M.,Hadjifrangiskou M.,Hultgren S. J.. Bacterial biofilms: development, dispersal, and therapeutic strategies in the dawn of the postantibiotic era CSH Perspect. Med. 2013 3 a010306 PMC3683961

[67]

Kolluru C.,Williams M.,Chae J.,Prausnitz M. R.. Recruitment and collection of dermal interstitial fluid using a microneedle patch Adv. Healthc. Mater. 2019 8 1801262 PMC6394862

[68]

Laszlo E.,De Crescenzo G.,Nieto-argüello A.,Banquy X.,Brambilla D.. Superswelling microneedle arrays for dermal interstitial fluid (prote)omics Adv. Funct. Mater. 2021 31 2106061

[69]

Himawan A.,Vora L. K.,Permana A. D..et al. Where microneedle meets biomarkers: futuristic application for diagnosing and monitoring localized external organ diseases Adv. Healthc. Mater. 2022 12 2202066 PMC11468661

[70]

Xu D.,Guo D.,Zhang J..et al. Innovative tumor interstitial fluid-triggered carbon dot-docetaxel nanoassemblies for targeted drug delivery and imaging of HER2-positive breast cancer Int. J. Pharm. 2024 657 124145

[71]

Jasuja H.,Jaswandkar S. V.,Katti D. R.,Katti K. S.. Interstitial fluid flow contributes to prostate cancer invasion and migration to bone; study conducted using a novel horizontal flow bioreactor Biofabrication 2023 15 025017 PMC10020972

[72]

Acs M.,Acs R.,Briandi C.,Eubanks E.,Rehman O.,Zhuang H.. Exploration of the relevance of microRNA signatures for cancer detection and multiclass cancer classification IEEE Access 2023 11 57268 84

[73]

Yan S.,Zheng H.,Zhao J.,Gao M.,Zhang X.. Quantification of GPC1(+) exosomes based on MALDI-TOF MS in situ signal amplification for pancreatic cancer discrimination and evaluation Anal. Chem. 2023 95 10196 203

[74]

Chen Y.,Gao D.,Zhu Q..et al. Rapid exosome isolation and in situ multiplexed detection of exosomal surface proteins and microRNAs on microfluidic platform Analyst 2023 148 2387 94

[75]

Fogh-Andersen N.,Altura B. M.,Altura B. T.,Siggaard-Andersen O.. Composition of interstitial fluid Clin. Chem. 1995 41 1522 5

[76]

Al Sulaiman D.,Chang J. Y. H.,Bennett N. R..et al. Hydrogel-coated microneedle arrays for minimally invasive sampling and sensing of specific circulating nucleic acids from skin interstitial fluid ACS Nano 2019 13 9620 8 PMC6746174

[77]

Li Y.,Wang Y.,Mei R..et al. Hydrogel-coated SERS microneedles for drug monitoring in dermal interstitial fluid ACS Sens. 2024 9 2567 74

[78]

Watkins Z.,Karajic A.,Young T.,White R.,Heikenfeld J.. Week-long operation of electrochemical aptamer sensors: new insights into self-assembled monolayer degradation mechanisms and solutions for stability in serum at body temperature ACS Sens. 2023 8 1119 31 PMC10443649

[79]

Harder J.,Schröder J.. RNase 7, a novel innate immune defense antimicrobial protein of healthy human skin J. Biol. Chem. 2002 277 46779 84

[80]

Shukla S.,Machekposhti S. A.,Joshi N.,Joshi P.,Narayan R. J.. Microneedle-integrated device for transdermal sampling and analyses of targeted biomarkers Small Sci. 2023 3 2200087

[81]

Facchinetti A.,Sparacino G.,Cobelli C.. Reconstruction of glucose in plasma from interstitial fluid continuous glucose monitoring data: role of sensor calibration J. Diabetes Sci. Technol. 2007 1 617 23

[82]

Shao J.,Li X.,Li Y.,Lin J.,Huang P.. Self-heating multistage microneedle patch for topical therapy of skin cancer Adv. Mater. 2024 36 2308217

[83]

Sonner Z.,Wilder E.,Heikenfeld J..et al. The microfluidics of the eccrine sweat gland, including biomarker partitioning, transport, and biosensing implications Biomicrofluidics 2015 9 031301 PMC4433483

[84]

Luchini A.,Fredolini C.,Espina B..et al. Nanoparticle technology: addressing the fundamental roadblocks to protein biomarker discovery Curr. Mol. Med. 2010 10 133 41 PMC2873152

[85]

Boysen T. C.,Yanagawa S.,Sato F.,Sato K.. A modified anaerobic method of sweat collection J. Appl. Physiol. 1984 56 1302 7

[86]

Jajack A.,Brothers M.,Kasting G.,Heikenfeld J.. Enhancing glucose flux into sweat by increasing paracellular permeability of the sweat gland PLoS ONE 2018 13 e0200009 PMC6047769

[87]

Crandall C. G.. Mechanisms and controllers of eccrine sweating in humans Front. Biosci. 2010 S2 685 96 PMC2866164

[88]

Hianik T.,Ostatná V.,Sonlajtnerova M.,Grman I.. Influence of ionic strength, pH and aptamer configuration for binding affinity to thrombin Bioelectrochemistry 2007 70 127 33

[89]

Csősz, É.; Emri, G.; Kalló, G.; Tsaprailis, G.; Tőzsér, J. Highly abundant defense proteins in human sweat as revealed by targeted proteomics and label-free quantification mass spectrometry J. Eur. Acad. Dermatol. Venereol. 2015 29 2024 31

[90]

Gao W.,Emaminejad S.,Nyein H. Y. Y..et al. Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis Nature 2016 529 509 14 PMC4996079

[91]

Jia M.,Chew W. M.,Feinstein Y.,Skeath P.,Sternberg E. M.. Quantification of cortisol in human eccrine sweat by liquid chromatography - tandem mass spectrometry Analyst 2016 141 2053 60

[92]

Heikenfeld J.. Non-invasive analyte access and sensing through eccrine sweat: challenges and outlook circa 2016 Electroanalysis 2016 28 1242 9

[93]

Leung K. K.,Gerson J.,Emmons N.,Heemstra J. M.,Kippin T. E.,Plaxco K. W.. The use of xenonucleic acids significantly reduces the in vivo drift of electrochemical aptamer-based sensors Angew. Chem. Int. Ed. 2024 63 e202316678 PMC11821280

[94]

Vallée-bélisle A.,Ricci F.,Plaxco K. W.. Thermodynamic basis for the optimization of binding-induced biomolecular switches and structure-switching biosensors Proc. Natl. Acad. Sci. U.S.A. 2009 106 13802 7 PMC2728975

[95]

Lin S.,Cheng X.,Zhu J..et al. Wearable microneedle-based electrochemical aptamer biosensing for precision dosing of drugs with narrow therapeutic windows Sci. Adv. 2022 8 eabq4539 PMC9506728

[96]

Bakhshandeh F.,Zheng H.,Barra N. G..et al. Wearable aptalyzer integrates microneedle and electrochemical sensing for in vivo monitoring of glucose and lactate in live animals Adv. Mater. 2024 36 2313743

[97]

Ye C.,Wang M.,Min J..et al. A wearable aptamer nanobiosensor for non-invasive female hormone monitoring Nat. Nanotechnol. 2023 19 330 7 PMC10954395

[98]

He R.,Liu H.,Niu Y.,Zhang H.,Genin G. M.,Xu F.. Flexible miniaturized sensor technologies for long-term physiological monitoring npj Flex. Electron. 2022 6 20

[99]

Han S.,Yamamoto S.,Jung C.,Jin D. Y.,Lee T.,Kim J.. Wearable sensors for monitoring chronic kidney disease Commun. Mater. 2024 5 153

[100]

Timpel J.,Klinghammer S.,Riemenschneider L..et al. Sensors for in situ monitoring of oral and dental health parameters in saliva Clin. Oral Investig. 2023 27 5719 36

[101]

Pandit P.,Crewther B.,Cook C.,Punyadeera C.,Pandey A. K.. Sensing methods for stress biomarker detection in human saliva: a new frontier for wearable electronics and biosensing Mater. Adv. 2024 5 5339 50

[102]

Li X.,Liu S.,Huang X..et al. Aptamers-based wearable electrochemical sensors for continuous monitoring of biomarkers in vivo Microsyst. Nanoeng. 2025 11 241

[103]

Holmlin R. E.,Chen X.,Chapman R. G.,Takayama S.,Whitesides G. M.. Zwitterionic SAMs that resist nonspecific adsorption of protein from aqueous buffer Langmuir 2001 17 2841 50

[104]

Ferguson B. S.,Hoggarth D. A.,Maliniak D..et al. Real-time, aptamer-based tracking of circulating therapeutic agents in living animals Sci. Transl. Med. 2013 5 PMC4010950

[105]

Seo J.,Fu K.,Correa S.,Eisenstein M.,Appel E. A.,Soh H. T.. Real-time monitoring of drug pharmacokinetics within tumor tissue in live animals Sci. Adv. 2022 8 eabk2901 PMC8741190

[106]

Fu K.,Seo J. W.,Kesler V..et al. Accelerated electron transfer in nanostructured electrodes improves the sensitivity of electrochemical biosensors Adv. Sci. 2021 8 2102495

[107]

Downs A. M.,Gerson J.,Hossain M. N..et al. Nanoporous gold for the miniaturization of in vivo electrochemical aptamer-based sensors ACS Sens. 2021 6 2299 306

[108]

Daggumati P.,Matharu Z.,Seker E.. Effect of nanoporous gold thin film morphology on electrochemical DNA sensing Anal. Chem. 2015 87 8149 56

[109]

Yang W.,Gerasimov J. Y.,Lai R. Y.. Folding-based electrochemical DNA sensor fabricated on a gold-plated screen-printed carbon electrode Chem. Commun. 2009 2902

[110]

Matharu Z.,Daggumati P.,Wang L.,Dorofeeva T. S.,Li Z.,Seker E.. Nanoporous-gold-based electrode morphology libraries for investigating structure-property relationships in nucleic acid based electrochemical biosensors ACS Appl. Mater. Interfaces 2017 9 12959 66

[111]

Arroyo-currás N.,Scida K.,Ploense K. L.,Kippin T. E.,Plaxco K. W.. High surface area electrodes generated via electrochemical roughening improve the signaling of electrochemical aptamer-based biosensors Anal. Chem. 2017 89 12185 91

[112]

Welsh J. B.,Psavko S.,Zhang X.,Gao P.,Balo A. K.. Comparisons of fifth-, sixth-, and seventh-generation continuous glucose monitoring systems J. Diabetes Sci. Technol. 2022 18 143 7 PMC10899839

[113]

Battelino T.,Alexander C. M.,Amiel S. A..et al. Continuous glucose monitoring and metrics for clinical trials: an international consensus statement Lancet. Diabetes Endo. 2023 11 42 57

[114]

Chmayssem A.,Nadolska M.,Tubbs E..et al. Insight into continuous glucose monitoring: from medical basics to commercialized devices Microchim. Acta 2023 190 177

[115]

Downs A. M.,Bolotsky A.,Weaver B. M..et al. Microneedle electrochemical aptamer-based sensing: real-time small molecule measurements using sensor-embedded, commercially-available stainless steel microneedles Biosens. Bioelectron. 2023 236 115408

[116]

Reynoso M.,Chang A.,Wu Y..et al. 3D-printed, aptamer-based microneedle sensor arrays using magnetic placement on live rats for pharmacokinetic measurements in interstitial fluid Biosens. Bioelectron. 2024 244 115802

[117]

Wu Y.,Tehrani F.,Teymourian H..et al. Microneedle aptamer-based sensors for continuous, real-time therapeutic drug monitoring Anal. Chem. 2022 94 8335 45 PMC9202557

[118]

Keyvani F.,Ghavaminejad P.,Saleh M. A..et al. Integrated electrochemical aptamer biosensing and colorimetric pH monitoring via hydrogel microneedle assays for assessing antibiotic treatment Adv. Sci. 2024 11 2309027 PMC11538706

[119]

Chiang P.,Lin X.,Shin S..et al. Real-time and continuous L-tryptophan monitoring by electrochemical aptamer-enabled microneedle sensor array Sensor. Actuat. B-Chem. 2026 449 139056

[120]

Yue Jing L.,Fan Y.,Zhi Chen B..et al. An aptamer-integrated conductive microneedle biosensor for real-time transdermal cortisol monitoring Chem. Eng. J. 2024 502 157488

[121]

Keyvani F.,Zheng H.,Kaysir M. R..et al. A hydrogel microneedle assay combined with nucleic acid probes for on-site detection of small molecules and proteins Angew. Chem. Int. Ed. 2023 62 e202301624

[122]

Yuan R.,Cai J.,Li J..et al. Integrated microneedle aptasensing platform toward point-of-care monitoring of bacterial infections and treatment ACS Sens. 2025 10 5684 93

[123]

Fakeih E.,Shetty S. S.,Hanif W.,Mutabagani K.,Salama K. N.,Alsulaiman D.. A Microneedle-based Ige aptasensor for transdermal detection of food allergy sensitization ACS Materials Lett. 2025 7 3595 603

[124]

Friedel M.,Werbovetz B.,Drexelius A..et al. Continuous molecular monitoring of human dermal interstitial fluid with microneedle-enabled electrochemical aptamer sensors Lab Chip 2023 23 3289 99 PMC11875127

[125]

Chen S.,Li L.,Zhao C.,Zheng J.. Surface hydration: Principles and applications toward low-fouling/nonfouling biomaterials Polymer 2010 51 5283 93

[126]

Kesler V.,Fu K.,Chen Y..et al. Tailoring electrode surface charge to achieve discrimination and quantification of chemically similar small molecules with electrochemical aptamers Adv. Funct. Mater. 2022 33 2208534 PMC9937077

[127]

Mcgowan M. P.,Trowbridge A. J.,Reitemeier J.,Jordan K. M.,Fu K. X.. Surface charge effects of monovalent and zwitterionic monolayers to differentiate structurally similar aminoglycosides with electrochemical aptamer biosensors Biosens. Bioelectron. 2025 276 117229

[128]

Li S.,Wang Y.,Zhang Z.,Wang Y.,Li H.,Xia F.. Exploring end-group effect of alkanethiol self-assembled monolayers on electrochemical aptamer-based sensors in biological fluids Anal. Chem. 2021 93 5849 55

[129]

Li H.,Dauphin-Ducharme P.,Arroyo-Currás N..et al. A biomimetic phosphatidylcholine-terminated monolayer greatly improves the in vivo performance of electrochemical aptamer-based sensors Angew. Chem. Int. Ed. 2017 56 7492 5 PMC5660315

[130]

Duan H.,Peng S.,He S..et al. Antifouling zwitterionic coating enhances electrochemical aptamer-based sensors for therapeutic drug monitoring Nano Today 2026 66 102892

[131]

Kim S.,Gim T.,Jeong Y.,Ryu J. H.,Kang S. M.. Facile construction of robust multilayered PEG films on polydopamine-coated solid substrates for marine antifouling applications ACS Appl. Mater. Interfaces 2017 10 7626 31

[132]

Chen Y.,Fu K. X.,Cotton R..et al. A biochemical sensor with continuous extended stability in vivo Nat. Biomed. Eng. 2025 9 1517 30

[133]

Li S.,Dai J.,Zhu M..et al. Implantable hydrogel-protective DNA aptamer-based sensor supports accurate, continuous electrochemical analysis of drugs at multiple sites in living rats ACS Nano 2023 17 18525 38

[134]

Huldin G. F.,Huang J.,Reitemeier J.,Fu K. X.. Nafion coated nanopore electrode for improving electrochemical aptamer-based biosensing Faraday Discuss. 2025 257 316 32

[135]

Wang C.,Fan K.,Shirzaei Sani E..et al. A microfluidic wearable device for wound exudate management and analysis in human chronic wounds Sci. Transl. Med. 2025 17 eadt0882 PMC12173118

[136]

Wang M.,Ye C.,Yang Y..et al. Printable molecule-selective core-shell nanoparticles for wearable and implantable sensing Nat. Mater. 2025 24 589 98

[137]

Xu C.,Song Y.,Sempionatto J. R..et al. A physicochemical-sensing electronic skin for stress response monitoring Nat. Electron. 2024 7 168 79 PMC10906959

[138]

Song Y.,Tay R. Y.,Li J..et al. 3D-printed epifluidic electronic skin for machine learning–powered multimodal health surveillance Sci. Adv. 2023 9 eadi6492 PMC10499321

[139]

Min J.,Demchyshyn S.,Sempionatto J. R..et al. An autonomous wearable biosensor powered by a perovskite solar cell Nat. Electron. 2023 6 630 41 PMC10923186

[140]

Tu J.,Min J.,Song Y..et al. A wireless patch for the monitoring of C-reactive protein in sweat Nat. Biomed. Eng. 2023 7 1293 306 PMC10592261

[141]

Wang B.,Zhao C.,Wang Z..et al. Wearable aptamer-field-effect transistor sensing system for noninvasive cortisol monitoring Sci. Adv. 2022 8 eabk0967 PMC8730602

[142]

Zhang X.,Tang Y.,Wu H.,Wang Y.,Niu L.,Li F.. Integrated aptasensor array for sweat drug analysis Anal. Chem. 2022 94 7936 43

[143]

Zhang X.,Zhang J.,Cai Y..et al. Integrated electrochemical aptasensor array toward monitoring anticancer drugs in sweat Anal. Chem. 2024 96 4997 5005

[144]

Fu J.,Wang Y.,Ding Y..et al. Wearable ring sensor for monitoring biomarkers of atherosclerosis in sweat Talanta 2025 287 127608

[145]

Huang C.,Li D.,Liu J..et al. A flexible aptameric graphene field-effect nanosensor capable of automatic liquid collection/filtering for cytokine storm biomarker monitoring in undiluted sweat Adv. Funct. Mater. 2023 34 2309447

[146]

Gao Y.,Nguyen D. T.,Yeo T..et al. A flexible multiplexed immunosensor for point-of-care in situ wound monitoring Sci. Adv. 2021 7 eabg9614

[147]

Huang C.,Yang W.,Wang H..et al. Flexible/regenerative nanosensor with automatic sweat collection for cytokine storm biomarker detection ACS Nano 2024 18 21198 210

[148]

Gao W.,Ota H.,Kiriya D.,Takei K.,Javey A.. Flexible electronics toward wearable sensing Acc. Chem. Res. 2019 52 523 33

[149]

Chen S.,Qiao Z.,Niu Y..et al. Wearable flexible microfluidic sensing technologies Nat. Rev. Bioeng. 2023 1 950 71

[150]

Xu Y.,Ye Z.,Zhao G..et al. Phase-separated porous nanocomposite with ultralow percolation threshold for wireless bioelectronics Nat. Nanotechnol. 2024 19 1158 67 PMC11330368

[151]

Eiler J.,Hansen D.,Bingöl B.,Hansen K.,Heikenfeld J.,Thormann E.. In vitro evaluation of skin adhesives during perspiration Int. J. Adhes. Adhes. 2020 99 102574

[152]

Si Y.,Li C.,Hu J.,Zhang C.,Dong Z.. Bioinspired superwetting open microfluidics: from concepts, phenomena to applications Adv. Funct. Mater. 2023 33 2301017

[153]

Sun Y.,Wang J.,Lu Q..et al. Stretchable and smart wettable sensing patch with guided liquid flow for multiplexed in situ perspiration analysis ACS Nano 2024 18 2335 45

[154]

He X.,Xu T.,Gu Z..et al. Flexible and superwettable bands as a platform toward sweat sampling and sensing Anal. Chem. 2019 91 4296 300

[155]

Yang H.,Ji S.,Chaturvedi I..et al. Adhesive biocomposite electrodes on sweaty skin for long-term continuous electrophysiological monitoring ACS Mater. Lett. 2020 2 478 84

[156]

Yuan Q.,Fang H.,Wu X..et al. Self-adhesive, biocompatible, wearable microfluidics with erasable liquid metal plasmonic hotspots for glucose detection in sweat ACS Appl. Mater. Interfaces 2023 16 66810 8

[157]

Choi Y.,Jin P.,Lee S..et al. All-printed chip-less wearable neuromorphic system for multimodal physicochemical health monitoring Nat. Commun. 2025 16 5689 PMC12216833

[158]

Lu Y.,Yang G.,Wang S..et al. Stretchable graphene-hydrogel interfaces for wearable and implantable bioelectronics Nat. Electron. 2023 7 51 65

[159]

Sonner Z.,Wilder E.,Gaillard T.,Kasting G.,Heikenfeld J.. Integrated sudomotor axon reflex sweat stimulation for continuous sweat analyte analysis with individuals at rest Lab Chip 2017 17 2550 60

[160]

Li S.,Li C.,Wang Y.,Li H.,Xia F.. Re-engineering electrochemical aptamer-based biosensors to tune their useful dynamic range via distal-site mutation and allosteric inhibition Anal. Chem. 2020 92 13427 33

[161]

Singh N. K.,Chung S.,Chang A.,Wang J.,Hall D. A.. A non-invasive wearable stress patch for real-time cortisol monitoring using a pseudoknot-assisted aptamer Biosens. Bioelectron. 2023 227 115097

[162]

Downs A. M.,Plaxco K. W.. Real-time, in vivo molecular monitoring using electrochemical aptamer based sensors: opportunities and challenges ACS Sens. 2022 7 2823 32

[163]

Ogden N. E.,Kurnik M.,Parolo C.,Plaxco K. W.. An electrochemical scaffold sensor for rapid syphilis diagnosis Analyst 2019 144 5277 83 PMC6886667

[164]

Kang D.,Parolo C.,Sun S.,Ogden N. E.,Dahlquist F. W.,Plaxco K. W.. Expanding the scope of protein-detecting electrochemical DNA “scaffold” sensors ACS Sens. 2018 3 1271 5 PMC6519109

[165]

Ma J.,Zhu J.,Li J.,Yang Y.. Design of a cost-effective inverted tetrahedral DNA nanostructure - based interfacial probe for electrochemical biosensing with enhanced performance Microchem. J. 2021 168 106455

[166]

Lin M.,Wan H.,Zhang J.,Wang Q.,Hu X.,Xia F.. Electrochemical DNA sensors based on MoS2-AuNPs for polynucleotide kinase activity and inhibition assay ACS Appl. Mater. Interfaces 2020 12 45814 21

[167]

Lai R. Y.. Folding- and dynamics-based electrochemical DNA sensors. In Enzymes as Sensors; Methods in Enzymology, Vol. 589; Elsevier, 2017; pp 221-52.

[168]

Shen Q.,Fan M.,Yang Y.,Zhang H.. Electrochemical DNA sensor-based strategy for sensitive detection of DNA demethylation and DNA demethylase activity Anal. Chim. Acta 2016 934 66 71

[169]

Idili A.,Amodio A.,Vidonis M.,Feinberg-somerson J.,Castronovo M.,Ricci F.. Folding-upon-binding and signal-on electrochemical DNA sensor with high affinity and specificity Anal. Chem. 2014 86 9013 9 PMC4165453

[170]

Luo X.,Du F.,Wu Y.,Gao L.,Li X.. Electrochemical DNA sensor for determination of p53 tumor suppressor gene incorporating gold nanoparticles modification Chin. J. Anal. Chem. 2013 41 1664 8

[171]

Li H.,Li S.,Dai J..et al. High frequency, calibration-free molecular measurements in situ in the living body Chem. Sci. 2019 10 10843 8

[172]

Li H.,Dauphin-ducharme P.,Ortega G.,Plaxco K. W.. Calibration-free electrochemical biosensors supporting accurate molecular measurements directly in undiluted whole blood J. Am. Chem. Soc. 2017 139 11207 13 PMC6519131

[173]

Lee T.,Chen L.,Wang E.,Wang C.,Lin Y.,Chen W.. Development of an electrochemical immunosensor for detection of cardiac troponin I at the point-of-care Biosensors 2021 11 210 PMC8301894

[174]

Feng X.,Gan N.,Lin S..et al. Ratiometric electrochemiluminescent aptasensor array for antibiotic based on internal standard method and spatial-resolved technique Sensor. Actuat. B-Chem. 2016 226 305 11

[175]

Chen Z.,Wang Y.,Du X.,Sun J.,Yang S.. Temperature-alternated electrochemical aptamer-based biosensor for calibration-free and sensitive molecular measurements in an unprocessed actual sample Anal. Chem. 2021 93 7843 50

[176]

Du Y.,Lim B. J.,Li B.,Jiang Y. S.,Sessler J. L.,Ellington A. D.. Reagentless, ratiometric electrochemical DNA sensors with improved robustness and reproducibility Anal. Chem. 2014 86 8010 6 PMC4372097

[177]

Leung K. K.,Downs A. M.,Ortega G.,Kurnik M.,Plaxco K. W.. Elucidating the mechanisms underlying the signal drift of electrochemical aptamer-based sensors in whole blood ACS Sens. 2021 6 3340 7 PMC12038169

[178]

Verrinder E.,Gerson J.,Leung K.,Kippin T. E.,Plaxco K. W.. Dual-frequency, ratiometric approaches to EAB sensor interrogation support the calibration-free measurement of specific molecules in vivo ACS Sens. 2024 9 3205 11

[179]

Downs A. M.,Gerson J.,Leung K. K.,Honeywell K. M.,Kippin T.,Plaxco K. W.. Improved calibration of electrochemical aptamer-based sensors Sci. Rep. 2022 12 5535 PMC8976050

[180]

Zupančič U.,Jolly P.,Estrela P.,Moschou D.,Ingber D. E.. Graphene enabled low-noise surface chemistry for multiplexed sepsis biomarker detection in whole blood Adv. Funct. Mater. 2021 31 2010638

[181]

Torrente-rodríguez R. M.,Lukas H.,Tu J..et al. SARS-CoV-2 RapidPlex: a graphene-based multiplexed telemedicine platform for rapid and low-cost COVID-19 diagnosis and monitoring Matter 2020 3 1981 98 PMC7535803

[182]

Cui F.,Yue Y.,Zhang Y.,Zhang Z.,Zhou H. S.. Advancing biosensors with machine learning ACS Sens. 2020 5 3346 64

[183]

Xue Y.,Ji W.,Jiang Y.,Yu P.,Mao L.. Deep learning for voltammetric sensing in a living animal brain Angew. Chem. Int. Ed. 2021 60 23777 83

[184]

Ali M.,Naeem F.,Tariq M.,Kaddoum G.. Federated learning for privacy preservation in smart healthcare systems: a comprehensive survey IEEE J. Biomed. Health Inform. 2023 27 778 89

[185]

Jiang C.,Wang G.,Hein R.,Liu N.,Luo X.,Davis J. J.. Antifouling strategies for selective in vitro and in vivo sensing Chem. Rev. 2020 120 3852 89

[186]

Sabaté Del Río J.,Henry O. Y. F.,Jolly P.,Ingber D. E.. An antifouling coating that enables affinity-based electrochemical biosensing in complex biological fluids Nat. Nanotechnol. 2019 14 1143 9

[187]

Jaffer I.,Fredenburgh J.,Hirsh J.,Weitz J.. Medical device-induced thrombosis: what causes it and how can we prevent it? J. Thromb. Haemost. 2015 13 S72 81

[188]

Weber M.,Steinle H.,Golombek S..et al. Blood-contacting biomaterials: in vitro evaluation of the hemocompatibility Front. Bioeng. Biotechnol. 2018 6 99

[189]

Khatoon Z.,Mctiernan C. D.,Suuronen E. J.,Mah T.,Alarcon E. I.. Bacterial biofilm formation on implantable devices and approaches to its treatment and prevention Heliyon 2018 4 e01067 PMC6312881

[190]

Caldara M.,Belgiovine C.,Secchi E.,Rusconi R.. Environmental, microbiological, and immunological features of bacterial biofilms associated with implanted medical devices Clin. Microbiol. Rev. 2022 35 e00221 20 PMC8768833

[191]

Samant P. P.,Prausnitz M. R.. Mechanisms of sampling interstitial fluid from skin using a microneedle patch Proc. Natl. Acad. Sci. U.S.A. 2018 115 4583 8 PMC5939066

[192]

Kolluru C.,Williams M.,Yeh J. S.,Noel R. K.,Knaack J.,Prausnitz M. R.. Monitoring drug pharmacokinetics and immunologic biomarkers in dermal interstitial fluid using a microneedle patch Biomed. Microdevices 2019 21 14 PMC6533066

[193]

Gromov P.,Gromova I.,Olsen C. J..et al. Tumor interstitial fluid - a treasure trove of cancer biomarkers BBA-Proteins. Proteom. 2013 1834 2259 70

[194]

Wiig H.,Swartz M. A.. Interstitial fluid and lymph formation and transport: physiological regulation and roles in inflammation and cancer Physiol. Rev. 2012 92 1005 60

[195]

Min J.,Tu J.,Xu C..et al. Skin-interfaced wearable sweat sensors for precision medicine Chem. Rev. 2023 123 5049 138 PMC10406569

[196]

Yang D. S.,Ghaffari R.,Rogers J. A.. Sweat as a diagnostic biofluid Science 2023 379 760 1

[197]

Sempionatto J. R.,Lasalde-Ramírez J. A.,Mahato K.,Wang J.,Gao W.. Wearable chemical sensors for biomarker discovery in the omics era Nat. Rev. Chem. 2022 6 899 915 PMC9666953

[198]

Yang Y.,Gao W.. Wearable and flexible electronics for continuous molecular monitoring Chem. Soc. Rev. 2019 48 1465 91

[199]

Malon R. S. P.,Sadir S.,Balakrishnan M.,Córcoles E. P.. Saliva-based biosensors: noninvasive monitoring tool for clinical diagnostics Biomed Res. Int. 2014 2014 1 20 PMC4172994

[200]

Sterzenbach T.,Helbig R.,Hannig C.,Hannig M.. Bioadhesion in the oral cavity and approaches for biofilm management by surface modifications Clin. Oral Investig. 2020 24 4237 60 PMC7666681

[201]

Qin S.,Jie Z.,Chen L..et al. Real-time monitoring of daunorubicin pharmacokinetics with nanoporous electrochemical aptamer-based sensors in vivo Sensor Actuat B-Chem 2024 411 135710

[202]

Booth M. A.,Erdal M. K.,Larson M..et al. Pilot phase clinical trial of a wearable, electrochemical aptamer-based patch for continuous drug concentration measurement Nat. Biotechnol. 2026 3010

[203]

He Z.,Duan H.,Zeng J..et al. Perovskite retinomorphic image sensor for embodied intelligent vision Sci. Adv. 2025 11 eads2834 PMC11698084

PDF

0

Accesses

0

Citation

Detail

Sections
Recommended

/