Design and Construction Mechanical Behavior Analysis of the Pile Cap for the Main Pylon of an A-Shaped Cable-Stayed Bridge

Debao Wu

Prestress Technology ›› 2026, Vol. 4 ›› Issue (1) : 80 -93.

PDF (1992KB)
Prestress Technology ›› 2026, Vol. 4 ›› Issue (1) :80 -93. DOI: 10.59238/j.pt.20251117001
Design and Construction
research-article
Design and Construction Mechanical Behavior Analysis of the Pile Cap for the Main Pylon of an A-Shaped Cable-Stayed Bridge
Author information +
History +
PDF (1992KB)

Abstract

To investigate the mechanical behavior of the pile cap for the main pylon of an A-shaped cable-stayed bridge without crossbeams, a realistic bridge of this type was selected as a case study. A grillage finite element model of the entire bridge was established using MIDAS to compare and analyze the effects of three different pile foundation layout schemes on the mechanical response of the pile cap. Subsequently, a local solid model of the pile cap was developed using MIDAS FEA NX to examine its transverse stress distribution under frequent load combinations. The results of comparison and selection revealed that the optimal scheme involves symmetrically arranging “2+2” piles at the dumbbell-shaped necking region in the center of the pile cap. This configuration effectively reduces the span, resulting in a more uniform and reasonable distribution of stress and deformation in the pile cap under frequent load combinations. The load-bearing mechanism of the pile cap is characterized by transverse prestressed steel tendons acting as key “balancing elements”. By establishing a prestress field within the pile cap, these tendons directly resist the horizontal thrust generated by the pylon, working together with the passive pile foundation to form a three-dimensional load-bearing system that internally balances, spatially distributes, and transfers the complex spatial forces from the superstructure. In addition, reinforcement meshes should be arranged in the prestress anchorage zones and in the regions between piles at the bottom of the pile cap to resist local tensile stress concentrations and control cracking. Traditional spatial grillage models exhibit limitations in analyzing the mechanical behavior of the thick and large pile caps in such A-shaped pylons, which may lead to distorted results and overestimation of local stresses. Therefore, the use of solid finite element models is recommended for accurate verification and design.

Keywords

A-shaped cable-stayed bridge / main pylon / pile cap / mechanical behavior / finite element analysis

Cite this article

Download citation ▾
Debao Wu. Design and Construction Mechanical Behavior Analysis of the Pile Cap for the Main Pylon of an A-Shaped Cable-Stayed Bridge. Prestress Technology, 2026, 4 (1) : 80-93 DOI:10.59238/j.pt.20251117001

登录浏览全文

4963

注册一个新账户 忘记密码

Conflict of interest

The author disclosed no relevant relationships.

Data availability statement

The data that support the findings of this study are available from the corresponding author, Wu, upon reasonable request.

References

[1]

Wang, D. Analysis of the Main Tower Base of a Cable-Stayed Bridge. Scientific and Technological Innovation Information 2014, 228-228, doi:10.3969/j.issn.1673-1328.2014.05.238. (in Chinese)

[2]

Wang, B. Structural Design and Static Analysis of the Cable-stayed Bridge on Xuefu Road. Prestress Technology 2023, 2, 63-71, doi:10.59238/j.pt.2023.02.006.

[3]

Xu, S. Force Analysis of Herringbone Bridge Pylon and Cross Brace System, and Comparison of Optimal Arrangement Scheme. Heilongjiang Science 2024, 15, 84-87+91, doi:10.3969/j.issn.1674-8646.2024.04.021. (in Chinese)

[4]

Li, F.; Wang, Z.; Huang, X. Analysis of Temperature Variation on Construction of Inverted Y-Shaped Bridge Tower. Word Bridges 2017, 45, 65-58, doi:10.3969/j.issn.1671-7767.2017.03.014. (in Chinese)

[5]

Zheng, H.; Chen, C. Calculation and Analysis of the Pier Cap of a Cable-Stayed Bridge. Highway Transportation Science and Technology (Applied Technology Edition) 2018, 14, 107-109, doi:CNKI:SUN:GLJJ.0.2018-06-042. (in Chinese)

[6]

Song, W. Analysis and Study on Stress of Base Slab for Main Diamond-shaped Pylon of Cable-stayed Bridge. Urban Roads Bridges & Flood Control 2019, 108-112, doi:10.16799/j.cnki.csdqyfh.2019.07.030. (in Chinese)

[7]

Pan, L.; Xu, W.; Liang, Z.; Wang, Y. Research on Cracking Control Techniques for Large-Volume Concrete Pile Caps Supporting Pylon Piers of Main Navigational Channel Bridge of Changtai Changjiang River Bridge. Qiaoliang Jianshe 2024, 54, 8-14, doi:10.20051/j.issn.1003-4722.2024.03.002. (in Chinese)

[8]

Wen, Z. Numerical Study on Hydration Heat of Concrete for Main Pier Cap of a Cable-Stayed Bridge in Xiangtan. Hunan Communication Science and Technology 2022, 48, 118-122+179, doi:10.3969/j.issn.1008-844X.2022.02.024. (in Chinese)

PDF (1992KB)

0

Accesses

0

Citation

Detail

Sections
Recommended

/