Adaptability Between Structural Characteristics and Additional Effective Damping Ratio Calculation Methods

Qiong Yao , Chao Yang , Yingying Liang , Jinzhu Lu , Jiannan Jin

Prestress Technology ›› 2026, Vol. 4 ›› Issue (1) : 24 -35.

PDF (1705KB)
Prestress Technology ›› 2026, Vol. 4 ›› Issue (1) :24 -35. DOI: 10.59238/j.pt.20250929002
Scientific Research
research-article
Adaptability Between Structural Characteristics and Additional Effective Damping Ratio Calculation Methods
Author information +
History +
PDF (1705KB)

Abstract

To investigate the significant influence of structural characteristics on the calculation of additional effective damping ratios in seismic energy dissipation structures, this study examines four typical structural types: steel frames, concrete frames, concrete frame-shear walls, and concrete shear walls. Additionally, the compatibility between the structural features and three calculation methods—the code method, energy ratio method, and time-variant method—is analyzed. Results show that the optimal method depends strongly on the structural type. For steel frames with low inherent damping and high ductility, the energy ratio method proves to be the most accurate. In the case of concrete frames, all three methods yield small calculation errors; however, the code method is recommended because its computational efficiency and accuracy are comparable to those of the time-variant method. For concrete frame-shear walls with notable stiffness variations, the time-variant method achieves the highest precision, although the code method remains a practical primary alternative. Regarding concrete shear walls, the code method tends to overestimate the damping effects, making the energy ratio method or time-variant method the preferred choice. This study establishes clear adaptation guidelines between structural characteristics and calculation methods, effectively resolves applicability issues, improves computational accuracy and design efficiency, and provides an important basis for the engineering application of viscous dampers.

Keywords

viscous fluid damper / additional effective damping ratio / seismic-damped structures / compatibility of calculation methods / different calculation methods

Cite this article

Download citation ▾
Qiong Yao, Chao Yang, Yingying Liang, Jinzhu Lu, Jiannan Jin. Adaptability Between Structural Characteristics and Additional Effective Damping Ratio Calculation Methods. Prestress Technology, 2026, 4 (1) : 24-35 DOI:10.59238/j.pt.20250929002

登录浏览全文

4963

注册一个新账户 忘记密码

Conflict of interest

All the authors disclosed no relevant relationships.

Data availability statement

The data that support the findings of this study are available from the corresponding author, Yang, upon reasonable request.

References

[1]

Ministry of Housing and Urban-Rural Development of the People's Republic of China. JGJ 297-2013 Technical Specification for Seismic Energy Dissipation of Buildings. China Architecture & Building Press: Beijing, 2013. (in Chinese)

[2]

Ding, Y.; Liu, S.; Li, J. Analysis of Additional Damping Ratio Calculation Methods of Nonlinear Viscous Damping Structure Under Frequent Earthquake. Earthquake Resistant Engineering and Retrofitting 2017, 39, 78-83, doi:10.16226/j.issn.1002-8412.2017.01.012. (in Chinese)

[3]

Zhou, Y.; Qu, T.; Xu, X.; Shang, C. Research on Time-Varying Calculation Method of Additional Effective Damping Ratio Based on Strain Energy Method. Building Structure 2019, 49, 103-108, doi:10.19701/j.jzjg.2019.11.019. (in Chinese)

[4]

Xu, X.; Qu, T.; Zhou, Y.; Sun, Z.; Duan, J. Analysis and Research on Calculation Method of Additional Effective Damping Ratio in BRB Energy Dissipation Structure Design. Building Structure 2018, 48, 89-95, doi:10.19701/j.jzjg.2018.17.016. (in Chinese)

[5]

Weng, D.; Li, C.; Hu, X.; Luo, H.; Zhang, R. Calculation of Additional Effective Damping Ratio of Structures based on Modal Damping Energy Dissipation. China Civil Engineering Journal 2016, 49, 19-24+31, doi:10.15951/j.tmgcxb.2016.s1.004. (in Chinese)

[6]

Duan, C.; Lei, J.; Yang, L. Study on Effect of Damping Exponent on Additional Damping Ratio of Structures with Viscous Dampers. Structural Engineers 2023, 39, 78-87, doi:10.15935/j.cnki.jggcs.2023.06.022. (in Chinese)

[7]

He, W.; Chen, C.; Liu, Y.; Liu, W. Comparative Study of Equivalent Damping Ratio Calculation Methods for a Structure with Viscous Dampers. Structural Engineers 2016, 32, 10-16, doi:10.15935/j.cnki.jggcs.2016.01.003. (in Chinese)

[8]

Wu, Z.; Xue, Y.; Wang, C.; Gao, J.; Cheng, X. Research on Additional Damping Ratio Calculation Methods Under Frequent Earthquake. Journal of Building Structures 2013, 34, 19-25, doi:10.14006/j.jzjgxb.2013.12.004. (in Chinese)

[9]

Song, L. Study on the Formula of Equivalent Damping Ratio of Viscous Damper. Earthquake Resistant Engineering and Retrofitting 2014, 36, 52-56. (in Chinese)

[10]

Hu, X.; Ren, X.; Weng, D.; Xu, B.; Ding, S.; Zhou, H. Research on Calculation of Equivalent Damping Ratio of Structure with Viscous Dampers. Chinese Quarterly of Mechanics 2013, 34, 114-124, doi:10.15959/j.cnki.0254-0053.2013.01.013. (in Chinese)

[11]

Lu, W.; Liu, W.; Wang, T. Calculation Method for Additional Equivalent Damping Ratio of Energy Dissipation Structure. Journal of Nanjing Tech University (Natural Science Edition) 2009, 31, 97-100. (in Chinese)

[12]

Zhou, Y. The Design Theory and Application of Viscous Damping Seismic Isolation Structures; Wuhan University of Technology Press: Wuhan, 2013.

[13]

Ministry of Housing and Urban-Rural Development of the People's Republic of China. GB 50011-2010 Code for Seismic Design of Buildings. China Architecture & Building Press: Beijing. 2010. (in Chinese)

PDF (1705KB)

0

Accesses

0

Citation

Detail

Sections
Recommended

/