This study was conducted to compare the difference between the use of a puncture angle guide device assisted needle insertion and manual needle entry for the treatment of single metastatic lymph nodes above the thoracic entrance by 125I seeds implantation, and explore the feasibility and safety of 125I seeds implantation assisted by the puncture angle guide device. Twenty patients who underwent 125I seeds implantation for the treatment of single metastatic lymph nodes above the thoracic entrance at Jiangsu Cancer Hospital from April 2023 to December 2024 were enrolled in this study, and they were randomly divided into two groups. In the Auxiliary group, the puncture angle guide device was used for 125I seeds implantation, while in the Manual group, the needles were deployed only by hand for 125I seeds implantation. The puncture time, the number of puncture needle adjustments, the number of CT scans, the number of implanted seeds, the dosimetry indicators, and the occurrence of complications were compared between the two groups, and the differences were statistically analyzed. Both groups successfully completed the 125I seeds implantation. The needle deployment time, the number of puncture needle adjustments, and the number of CT scans in the Auxiliary group were less than those in the Manual group, and the difference was statistically significant (p <.05). There was no statistical difference in the dosimetry parameters, the difference in dosimetry parameters, and the incidence of complications (Bleeding, pneumothorax) between the two groups before or after the operation (p >.05). The puncture angle guide device assisted 125I seeds implantation is safe and feasible. Compared with the manual deployment of needles, the puncture time, the number of puncture needle adjustments, and the number of intraoperative CT scans are significantly reduced, which can be used in clinical applications.
| [1] |
Sakurai T, Takamatsu S, Shibata S, et al. Incidence and dosimetric predictive factors of late rectal toxicity after low-dose-rate brachytherapy combined with volumetric modulated arc therapy in high-risk prostate cancer at a single institution: retrospective study. Brachytherapy. 2021; 20(3): 584-594.
|
| [2] |
Kobayashi K, Murakami N, Takahashi K, et al. Tensor regression-based model to investigate heterogeneous spatial radiosensitivity after 125I seed implantation for prostate cancer. In Vivo. 2021; 35(1): 489-497.
|
| [3] |
中华医学会放射肿瘤治疗学分会, 中国医师协会放射肿瘤治疗医师分会. CT引导放射性125I粒子植入治疗胰腺癌专家共识(2023版). 中华放射医学与防护杂志, 2023, 43(5): 321-327 Chinese Society for Radiation Oncology. Chinese Medical Doctor Association Radiotherapy Physician Branch. Expert consensus on computed tomography-guided 125I seed implantation for pancreatic cancer (2023 edition). Chin J Radiat Med Prot. 2023; 43(5): 321-327.
|
| [4] |
Jiang Y, Zhen P, Dai J, et al. Long-term safety and efficacy of CT-guided 125I radioactive seed implantation as a salvage therapy for recurrent head and neck squamous carcinoma: a multicenter retrospective study. Front Oncol. 2021; 11:645077.
|
| [5] |
Qiu B, Jiang Y, Ji Z, et al. The accuracy of individualized 3D-printing template-assisted 125I radioactive seed implantation for recurrent/metastatic head and neck cancer. Front Oncol. 2021; 11:664996.
|
| [6] |
Chen Y, Jiang Y, Ji Z, et al. Efficacy and safety of CT-guided 125I seed implantation as a salvage treatment for locally recurrent head and neck soft tissue sarcoma after surgery and external beam radiotherapy: a 12-year study at a single institution. Brachytherapy. 2020; 19(1): 81-89.
|
| [7] |
Xu T, Peng WD, Gu X, Yu WJ. Endobronchial ultrasound-guided iodine-125 radioactive seed implantation as a novel therapy for mediastinal tumors. Cancer Biother Radiopharm. 2019; 34(9): 547-550.
|
| [8] |
Woulfe P, Sullivan FJ, Byrne L, et al. Optical fibre based real-time measurements during an LDR prostate brachytherapy implant simulation: using a 3D printed anthropomorphic phantom. Sci Rep. 2021; 11(1):11160.
|
| [9] |
Porceddu SV, Padhya TA, Genden EM, et al. Management of the neck in head and neck cancer: American Society of Clinical Oncology clinical practice guideline. J Clin Oncol. 2023; 41(10): 1956-1974.
|
| [10] |
Wang J, Jiang P, Zhang Y, et al. Long-term efficacy and safety of CT-guided 125I radioactive seed implantation for locoregional recurrence of non-small cell lung cancer after surgery or radiation therapy: a retrospective study of 265 patients. J Contemp Brachytherapy. 2021; 13(1): 15-24.
|
| [11] |
Chen Y, Wang X, Zhou H, et al. Iodine-125 seed irradiation induces DNA damage and activates apoptosis in pancreatic cancer cells via the ATM/Chk2/p53 pathway. Front Oncol. 2023; 13:1127356.
|
| [12] |
Ibarra RA, Rojas B, Snyder L, et al. The role of brachytherapy in the treatment of hepatocellular carcinoma: a systematic review and meta-analysis. Brachytherapy. 2021; 20(3): 497-508.
|
| [13] |
Li H, Li J, Zhan Y, et al. Ultrasound-guided 125I seed implantation in treatment of abdominal wall metastases. Cancer Biother Radiopharm. 2019; 34(4): 218-223.
|
| [14] |
Ji Z, Huo B, Liu S, et al. Clinical outcome of CT-guided stereotactic ablative brachytherapy for unresectable early non-small cell lung cancer: a retrospective, multicenter study. Front Oncol. 2021; 11:706242.
|
| [15] |
Wei S, Li C, Li M, et al. Radioactive iodine-125 in tumor therapy: advances and future directions. Front Oncol. 2021; 11:717180.
|
| [16] |
Du P, Xiao Y, Lu W. Modified fan-shaped distribution technology for computed tomography (CT)-guided radioactive seed implantation in lung cancer patients with lung dysfunction. Med Sci Monit. 2017; 23: 4366-4375.
|
| [17] |
Li Q, Tian Y, Yang D, Liang Y, Cheng X, Gai B. Permanent iodine-125 seed implantation for the treatment of nonresectable retroperitoneal malignant tumors. Technol Cancer Res Treat. 2019; 18:1533033819825845.
|
| [18] |
Zhang L, Li H, Bao Y, et al. A deep learning-based approach for automated preplanning of iodine-125 seed implantation in prostate cancer. Med Phys. 2023; 50(5): 2870-2880.
|
| [19] |
Zhao J, Wang J, Guo F, et al. Ultrasound-guided iodine-125 seed implantation for locally recurrent head and neck cancer: assessment of implant quality and dosimetric outcomes. Front Oncol. 2024; 14:1349190.
|
| [20] |
Liu Y, Wang J, Li Z, et al. A prospective study of 3D-printed template-guided versus conventional CT-guided iodine-125 seed implantation for peripheral lung cancer. Brachytherapy. 2024; 23(1): 45-54.
|