Research on one-piece structure target flow sensing technology based on fiber Bragg grating

Chuntong Liu , Zhengyi Zhang , Hongcai Li , Zhenxin He , Xiaofeng Zhao , Rongjing Wu

Photonic Sensors ›› 2015, Vol. 6 ›› Issue (4) : 303 -311.

PDF
Photonic Sensors ›› 2015, Vol. 6 ›› Issue (4) : 303 -311. DOI: 10.1007/s13320-016-0352-6
Regular

Research on one-piece structure target flow sensing technology based on fiber Bragg grating

Author information +
History +
PDF

Abstract

In view of problems existing in the detection of the traditional hydraulic system, such as the large volume of sensor and the low measurement accuracy, a new one-piece target type flow sensor is designed and researched based on fiber Bragg grating (FBG). A compact structure is designed, which is convenient to be dismantled, processed, and installed, based on the analysis of the principle of FBG and the structure of target type flow sensor. The force of target put in fluid flow is turned into the FBG wavelength drift, with a corresponding relationship. The problem on the cross sensitivities of the temperature and strain is solved effectively by using double FBG symmetrically pasted on the both surfaces of the cantilever. The impact on the fluid state is analyzed through simulation in the software FLUENT, and the results show that the impact was smaller than that of the traditional structure. The results of experiments in the hydraulic system show that there is a good linear relationship between the change in the dual FBG central wavelength and mass loading on the target sheet has a good linear relationship, and the sensitivity is twice that of a single FBG sensitivity.

Keywords

Fiber Bragg grating / flow sensor / target type structure / equal intensity cantilever beam

Cite this article

Download citation ▾
Chuntong Liu, Zhengyi Zhang, Hongcai Li, Zhenxin He, Xiaofeng Zhao, Rongjing Wu. Research on one-piece structure target flow sensing technology based on fiber Bragg grating. Photonic Sensors, 2015, 6(4): 303-311 DOI:10.1007/s13320-016-0352-6

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Liang L. Z., Chen Z. J., Wang Y. B.. Signal detector of propeller flow velocity meter. Process Automation Instrumentation, 2003, 24(5): 41-43.

[2]

Zheng D. D., Zhang P. Y., Zhang T.. A method based on a novel flow pattern model for the flow adaptability study of ultrasonic flowmeter. Flow Measurement and Instrumentation, 2013, 29(1): 25-31.

[3]

Leeungculsatien T., Lucas G. P.. Measurement of velocity profiles in multiphase flow using a multi-electrode electromagnetic fow meter. Flow Measurement and Instrumentation, 2013, 31(6): 86-95.

[4]

Hu C. L., Lin Z. S., Chen Y. Y.. Portable laser Doppler flowmeter for microcirculation detection. Biomedical Engineering Letters, 2013, 3(2): 109-114.

[5]

Wang D. S.. The study of flow measurement based on the optical fiber gating system, 2013

[6]

Zhang X. Z., Li X. Y.. Optical fiber flow sensor. Transducer Technology, 1999, 18(1): 57-59.

[7]

Majiimder M., Gangopadhyay T. K., Chakraborty A. K.. Fiber Bragg gratings in structural health monitoring-present status and applications. Sensors and Actuators: A Physical, 2008, 147(1): 150-164.

[8]

Wang Y. B., J Lan H.. Study of fiber Bragg grating sensor system based on wavelength-division multiplexing/time-devision mltiplexing. Acta Photonica Sinica, 2010, 30(8): 2196-2201.

[9]

Robertson D. C., Niewczas P., Mcdonald J. R.. Interrogation of a dual-fiber-Bragg-grating sensor using an arrayed waveguide grating. IEEE Transactions on Instrumentation and Measurement, 2007, 56(6): 2641-2645.

[10]

Jiang M. S., Sui Q. M., Jia L.. FBG-based ultrasonic wave detection and acoustic emission linear location system. Optoelectronics Letters, 2012, 8(3): 220-223.

[11]

Yu D. K., Jia Z. A., Qiao X. G.. FBG sensors combining target with cantilever beam for simultaneous measurement of flow-rate/ temperature. Journal of Optoelectronics Laser, 2010, 21(5): 710-713.

[12]

Wang Z. F., Wang J., Sui Q. M.. A target-type fiber Bragg grating flow velocity sensor. Journal of Optoelectronics Laser, 2012, 23(1): 1-8.

[13]

Wang D. S., Wang Y. T., Pan W. W.. A circular target flow measurement system. Applied Mechanics and Materials, 2013, 427–429, 1233-1236.

[14]

Li H. C., Liu C. T., Feng Y. B.. An embedded nozzle differential pressure style flow sensor based on FBG. Journal of Optoelectronics Laser, 2014, 25(10): 1886-1891.

[15]

Takashima S., Asanuma H., Niitsuma H.. A water flowmeter using dual fiber Bragg grating sensors and cross-correlation technique. Sensors and Actuarors A: Physical, 2004, 116(1): 66-74.

[16]

Zhao Y., Chen K., Yang J.. Novel target type flowmeter based on a differential fiber Bragg grating sensor. Measurement, 2005, 38(3): 230-235.

[17]

Hu Y. R., Tian Y. H., Li C.. Fiber Bragg grating flow sensor. Chinese Journal of Sensors and Actuators, 2010, 23(4): 471-474.

AI Summary AI Mindmap
PDF

124

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/