Early warning smartphone diagnostics for water security and analysis using real-time pH mapping
Md. Arafat Hossain , John Canning , Sandra Ast , Peter J. Rutledge , Abbas Jamalipour
Photonic Sensors ›› 2014, Vol. 5 ›› Issue (4) : 289 -297.
Early warning smartphone diagnostics for water security and analysis using real-time pH mapping
Early detection of environmental disruption, unintentional or otherwise, is increasingly desired to ensure hazard minimization in many settings. Here, using a field-portable, smartphone fluorimeter to assess water quality based on the pH response of a designer probe, a map of pH of public tap water sites has been obtained. A custom designed Android application digitally processed and mapped the results utilizing the global positioning system (GPS) service of the smartphone. The map generated indicates no disruption in pH for all sites measured, and all the data are assessed to fall inside the upper limit of local government regulations, consistent with authority reported measurements. This implementation demonstrates a new security concept: network environmental forensics utilizing the potential of novel smartgrid analysis with wireless sensors for the detection of potential disruption to water quality at any point in the city. This concept is applicable across all smartgrid strategies within the next generation of the Internet of Things and can be extended on national and global scales to address a range of target analytes, both chemical and biological.
Lab-in-a-phone / Internet of Things / optical sensing and sensor / smartphone sensor / photonic sensor / fluorescence / water security
| [1] |
Australian government’s National HealthMedical Research Council Australian drinking water guidelines 6. National Water Quality Management Strategy, 2013, 2, 174. |
| [2] |
Sydney Water, Quarterly Drinking Water Quality Report, 1 Jul. 2013 to 30 Sep. 2013, Sydney, Australian: Sydney Water. www.sydneywater.com.au, 2014. |
| [3] |
|
| [4] |
|
| [5] |
|
| [6] |
|
| [7] |
|
| [8] |
|
| [9] |
|
| [10] |
|
| [11] |
|
| [12] |
|
| [13] |
|
| [14] |
|
| [15] |
|
| [16] |
|
| [17] |
D. N. Breslauer, R. N. Maamari, N. A. Switz, W. A. Lam, and D. A. Fletcher, “Mobile phone based clinical microscopy for global health applications,” PLoS ONE, 2009, 4(7): e6320-1–e6320-7, 2009. |
| [18] |
Z. J. Smith, K. Chu, A. R. Espenson, A. Gryshuk, M. Molinaro, D. M. Dwyre, et al., “Cell phone-based platform for biomedical device development and education applications,” PLoS ONE, 2011, 6(3): e17150-1–e17150-11. |
| [19] |
|
| [20] |
A. Skandarajah, C. D. Reber, N. A. Switz, and D. A. Fletcher, “Quantitative imaging with a mobile phone microscope,” PLoS ONE, 2014, 9(5): e96906-1–e96906-12. |
| [21] |
|
| [22] |
|
| [23] |
|
| [24] |
|
| [25] |
|
| [26] |
|
| [27] |
|
| [28] |
|
| [29] |
|
| [30] |
|
| [31] |
|
| [32] |
|
| [33] |
|
| [34] |
|
| [35] |
|
| [36] |
International Telecommunication Union, Mobile-cellular subscriptions 2013, Available online: http://www.itu.int/en/ITU-D/Statistics, 2015. |
| [37] |
|
| [38] |
|
| [39] |
J. Canning, M. Naqshbandi, and M. J. Crossley, “Measurement of rhodamine B absorption in self-assembled silica microwires using a Tablet as the optical source,” in Proc. SPIE, vol. 8351, pp. 83512E-1–83512E -5, 2012. |
| [40] |
|
| [41] |
|
| [42] |
Sesorex, SAM-1 for iPhone, iPad and Android, Avialable online: http://www.sensorex.com/products /more/sam_1, 2015. |
| [43] |
|
/
| 〈 |
|
〉 |