Fiber-optic Fabry-Perot hydrogen sensor coated with Pd-Y film

Caibin Yu , Li Liu , Xiaoxiao Chen , Qunfeng Liu , Yuan Gong

Photonic Sensors ›› 2014, Vol. 5 ›› Issue (2) : 142 -145.

PDF
Photonic Sensors ›› 2014, Vol. 5 ›› Issue (2) : 142 -145. DOI: 10.1007/s13320-015-0237-0
Regular

Fiber-optic Fabry-Perot hydrogen sensor coated with Pd-Y film

Author information +
History +
PDF

Abstract

A fiber-optic Fabry-Perot hydrogen sensor was developed by measuring the fringe contrast changes at different hydrogen concentrations. The experimental results indicated that the sensing performance with the Pd-Y film was better than that with the Pd film. A fringe contrast with a decrease of 0.5 dB was detected with a hydrogen concentration change from 0% to 5.5%. The temperature response of the sensor was also measured.

Keywords

Optical fiber sensor / hydrogen sensor / Pd-Y film / fringe contrast / temperature characteristics

Cite this article

Download citation ▾
Caibin Yu, Li Liu, Xiaoxiao Chen, Qunfeng Liu, Yuan Gong. Fiber-optic Fabry-Perot hydrogen sensor coated with Pd-Y film. Photonic Sensors, 2014, 5(2): 142-145 DOI:10.1007/s13320-015-0237-0

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Boon-brett L, Bousek J, Castello P, Salyk O, Harskamp F, Aldea L, . Reliability of commercially available hydrogen sensors for detection of hydrogen at critical concentrations: part I — testing facility and methodologies. International Journal of Hydrogen Energy, 2008, 33(24): 7648-7657.

[2]

Boon-brett L, Bousek J, Moretto P. Reliability of commercially available hydrogen sensors for detection of hydrogen at critical concentrations: part II — selected sensor test results. International Journal of Hydrogen Energy, 2009, 34(1): 562-571.

[3]

Christophe C, Marc D, Driss L, Patrice M. Hybrid fiber gratings coated with a catalytic sensitive layer for hydrogen sensing in air. Optics Express, 2008, 16(21): 16854-16859.

[4]

Bevenot X, Trouillet A, Veillas C, Gagnaire H, Clement M. Surface plasmon resonance hydrogen sensor using an optical fibre. Measurement Science and Technology, 2002, 13(1): 118-124.

[5]

Sumida S, Okazaki S, Asakura S, Nakagawa H, Murayama H, Hasegawa T. Distributed hydrogen determination with fiber-optic sensor. Sensors and Actuators B: Chemical, 2005, 108(1–2): 508-514.

[6]

Caucheteur C, Debliquy M, Lahem D, Megret P. Catalytic fiber Bragg grating sensor for hydrogen leak detection in air. IEEE Photonics Technology Letters, 2008, 20(2): 96-98.

[7]

Buric M, Chen T, Maklad M, Swinehart P R, Chen K P. Multiplexable low-temperature fiber Bragg grating hydrogen sensors. IEEE Photonics Technology Letters, 2009, 21(21): 1594-1596.

[8]

Wang M, Yang M, Cheng J, Dai J, Yang M, Wang D. Femtosecond laser fabricated micro Mach-Zehnder interferometer with Pd film as sensing materials for hydrogen sensing. Optics Letters, 2012, 37(11): 1940-1942.

[9]

David M, Donato L, Dalia M E, Joel V. Optical microfibers decorated with PdAu nanoparticles for fast hydrogen sensing. Sensors and Actuators B: Chemical, 2010, 151(1): 219-222.

[10]

David M, Donato L, Dalia M. Fast response fiber optic hydrogen sensor based on palladium and gold nano-layers. Sensors and Actuators B: Chemical, 2009, 136(2): 562-566.

[11]

Yang M, Dai J. Fiber optic hydrogen sensors: a review. Photonic Sensors, 2014, 4(4): 300-324.

[12]

Gong Y, Zhao T, Rao Y, Wu Y, Guo Y. A ray-transfer-matrix model for hybrid fiber Fabry-Perot sensor based on graded-index multimode fiber. Optics Express, 2010, 18(15): 15844-15852.

AI Summary AI Mindmap
PDF

122

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/