Interferometer based on a D-shape chaotic optical fiber for measurement of multiparameters

Susana Silva , Luís Coelho , Philippe Roy , Orlando Frazão

Photonic Sensors ›› 2011, Vol. 2 ›› Issue (4) : 381 -384.

PDF
Photonic Sensors ›› 2011, Vol. 2 ›› Issue (4) : 381 -384. DOI: 10.1007/s13320-012-0078-z
Regular

Interferometer based on a D-shape chaotic optical fiber for measurement of multiparameters

Author information +
History +
PDF

Abstract

An interferometer based on a D-shape chaotic optical fiber for measurement of multiparameters was proposed. The sensing structure relied on a D-shape fiber section spliced in between two singlemode fibers and interrogated in transmission. The optical spectrum was composed by multiple interference loss peaks, which were sensitive to the refractive index, temperature and strain — maximum sensitivities of 95.2 nm/RIU, 10.5 pm/°C and −3.51 pm/μɛ, respectively, could be achieved.

Keywords

Optical fiber sensors / interferometer / chaotic fiber

Cite this article

Download citation ▾
Susana Silva, Luís Coelho, Philippe Roy, Orlando Frazão. Interferometer based on a D-shape chaotic optical fiber for measurement of multiparameters. Photonic Sensors, 2011, 2(4): 381-384 DOI:10.1007/s13320-012-0078-z

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Corke M., Kersey A. D., Jackson D. A., Jones J. D. C.. All-fiber Michelson thermometer. Electronics Letters, 1983, 19(13): 471-473.

[2]

Bucaro J. A., Dardy H. D., Carome E. F.. Fiber optic hydrophone. Journal of the Acoustical Society of America, 1977, 62(5): 1302-1304.

[3]

Swart P. L.. Long-period grating Michelson refractometric sensor. Measurement Science Technology, 2004, 15(8): 1576-1580.

[4]

Kersey A. D., Jackson D. A., Corke M.. A simple fiber Fabry-Perot sensor. Optics Communications, 1983, 45(2): 71-74.

[5]

Zhang J., Zhang Y., Sun W., Yuan L.. Multiplexing multimode fiber and Fizeau etalon a simultaneous measurement scheme of temperature and strain. Measurement Science Technology, 2009, 20(6): 065206.

[6]

Farahi F., Webb D. J., Jones J. D. C., Jackson D. A.. Simultaneous measurement of temperature and strain: cross-sensitivity considerations. Journal Lightwave Technology, 1990, 8(2): 138-142.

[7]

Doya V., Legrand O., Mortessagne F., Miniatura C.. Speckle statistics in a chaotic multimode fiber. Physical Review E, 2002, 65(5): 056223-1-056223-15.

[8]

Doya V., Legrand O., Michel C., Mortessagne F.. Optical scar in a chaotic fiber. European Physical Journal-Special Topics, 2007, 145(1): 49-61.

[9]

Leproux P., Février S., Doya V., Roy P., Pagnoux D.. Modeling and optimization of double-clad fiber amplifiers using chaotic propagation of the pump. Optical Fiber Technology, 2001, 7(4): 324-339.

[10]

Leproux P., Doya V., Roy P., Pagnoux D., Mortessagne F., Legrand O.. Experimental study of pump power absorption along rare-earth-doped double clad optical fibers. Optics Communication, 2003, 218(4–6): 249-254.

[11]

Doya V., Legrand O., Mortessagne F., Miniatura C.. Light scarring in an optical fiber. Physical Review Letters, 2002, 88(1): 014102.

[12]

Li E.. Temperature compensation of multimode-interference-based fiber devices. Optics Letters, 2007, 32(14): 2064-2066.

AI Summary AI Mindmap
PDF

120

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/