Exploring the Effectiveness of “Four-Point” Configuration Cannulated Compression Screw Implantation Protocol for the Fixation of Pauwels Type III Femoral Neck Fractures in Adults

Yujie Li , Zhenyu Wen , Zhang Jian , Naiqiang Zhuo , Shi Shen

Orthopaedic Surgery ›› 2026, Vol. 18 ›› Issue (8) : 1734 -1752.

PDF (3947KB)
Orthopaedic Surgery ›› 2026, Vol. 18 ›› Issue (8) :1734 -1752. DOI: 10.1111/os.70377
RESEARCH ARTICLE
Exploring the Effectiveness of “Four-Point” Configuration Cannulated Compression Screw Implantation Protocol for the Fixation of Pauwels Type III Femoral Neck Fractures in Adults
Author information +
History +
PDF (3947KB)

Abstract

Background: Pauwels type III femoral neck fractures (P3FNFs) are one of the common types of femoral neck fractures (FNF) caused by high-energy violent factors. This study aims to evaluate the efficacy of inverted cannulated cancellous screw (ICCS) assisted transversal cannulated screw (TCS) perpendicular to the fracture line in young adults with Pauwels type III femoral neck fractures.

Methods: Construct an internal fixation-fracture model through finite element analysis (FEA) and biomechanical test (BT) to simulate the stress environment of the human hip joint, and utilize the femoral neck system (FNS) model as a control to predict the biomechanical properties of ICCS + TCS. From January 2023 to December 2024, 21 patients with P3FNFs treated with ICCS + TCS were collected, and their recent radiographic and clinical outcomes were evaluated. The experimental data underwent statistical analysis using one-way ANOVA and independent samples t-test.

Result: ICCS + TCS exhibits biomechanical trends in FEA and BT that are essentially consistent with those of FNS. ICCS + TCS has stronger torsional stiffness and lower overall deformation, But the resistance to vertical shear force is weaker than FNS. All patients in this study successfully completed the surgery without complications such as vascular or nerve injuries. The follow-up period ranged from 8 to 25 months. The hip joint flexion-extension ROM, internal–external rotation ROM, and Harris score all significantly increased (p < 0.05). The shortening length of the femoral neck was 3.87 ± 0.44 mm.

Conclusion: ICCS + TCS exhibits biomechanical trends compared to FNS; meanwhile, it has stronger torsional resistance and load-bearing deformations. Simultaneously, ICCS + TCS has demonstrated favorable outcomes in clinical treatments. This study offers a novel approach for the treatment of P3FNFs.

Keywords

biomechanical analysis / femoral neck fracture / femoral neck system / finite element analysis / inverted cannulated cancellous screw / Pauwels III

Cite this article

Download citation ▾
Yujie Li, Zhenyu Wen, Zhang Jian, Naiqiang Zhuo, Shi Shen. Exploring the Effectiveness of “Four-Point” Configuration Cannulated Compression Screw Implantation Protocol for the Fixation of Pauwels Type III Femoral Neck Fractures in Adults. Orthopaedic Surgery, 2026, 18 (8) : 1734-1752 DOI:10.1111/os.70377

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

N. Ramadanov, I. Toma, H. Herkner, R. Klein, W. Behringer, and G. Matthes, “Factors That Influence the Complications and Outcomes of Femoral Neck Fractures Treated by Cannulated Screw Fixation,” Scientific Reports 10, no. 1 (2020): 758.

[2]

A. V. Florschutz, J. R. Langford, G. J. Haidukewych, and K. J. Koval, “Femoral Neck Fractures: Current Management,” Journal of Orthopaedic Trauma 29, no. 3 (2015): 121–129.

[3]

C. Zhang, Y. Zhang, B. Yu, et al., “Guidelines for Diagnosis and Treatment of Adult Femoral Neck Fractures,” Chinese Journal of Orthopaedic Trauma 20, no. 11 (2018): 921–928.

[4]

H. Fischer, T. Maleitzke, C. Eder, S. Ahmad, U. Stöckle, and K. F. Braun, “Management of Proximal Femur Fractures in the Elderly: Current Concepts and Treatment Options,” European Journal of Medical Research 26, no. 1 (2021): 86.

[5]

M. Knobe, S. Altgassen, K. J. Maier, et al., “Screw-Blade Fixation Systems in Pauwels Three Femoral Neck Fractures: A Biomechanical Evaluation,” International Orthopaedics 42, no. 2 (2018): 409–418.

[6]

G. P. Slobogean, S. A. Sprague, T. Scott, and M. Bhandari, “Complications Following Young Femoral Neck Fractures,” Injury 46, no. 3 (2015): 484–491.

[7]

E. H. Schemitsch, S. Sprague, M. J. Heetveld, et al., “Loss of Independence After Operative Management of Femoral Neck Fractures,” Journal of Orthopaedic Trauma 33, no. 6 (2019): 292–300.

[8]

G. Wang, Y. Tang, X. Wu, and H. Yang, “Finite Element Analysis of a New Plate for Pauwels Type III Femoral Neck Fractures,” Journal of International Medical Research 48, no. 2 (2020): 300060520903669.

[9]

F.-L. Wang, X. Yong-Mei, L. Gaoyu, Z. Ya-Zhong, and Z. Zi-Qiang, “Femoral Neck System Versus Cannulated Screws Forfixation of Femoral Neck Fractures,” Orthopedic Journal of China 31, no. 24 (2023): 2221–2225.

[10]

Z. Zhi-Kun, X. Zhi-Qing, G. Jin-Hua, G. Zhi-Bing, and W. Zhao-Ke, “Risk Factors of Femoral Head Necrosis After Internal Fixation for Femoral Neck Fracture in the Young and Middleaged,” Orthopedic Journal of China 26, no. 22 (2018): 2044–2049.

[11]

M. Beck, K. A. Siebenrock, B. Affolter, H. Nötzli, J. Parvizi, and R. Ganz, “Increased Intraarticular Pressure Reduces Blood Flow to the Femoral Head,” Clinical Orthopaedics and Related Research 424 (2004): 149–152.

[12]

Y. Xia, W. Zhang, H. Hu, L. Yan, S. Zhan, and J. Wang, “Biomechanical Study of Two Alternative Methods for the Treatment of Vertical Femoral Neck Fractures—A Finite Element Analysis,” Computer Methods and Programs in Biomedicine 211 (2021): 106409.

[13]

S. Patel, V. Kumar, V. Baburaj, and M. S. Dhillon, “The Use of the Femoral Neck System (FNS) Leads to Better Outcomes in the Surgical Management of Femoral Neck Fractures in Adults Compared to Fixation With Cannulated Screws: A Systematic Review and Meta-Analysis,” European Journal of Orthopaedic Surgery and Traumatology 33, no. 5 (2023): 2101–2109.

[14]

S. Huang, Y. Zhang, X. Zhang, et al., “Comparison of Femoral Neck System and Three Cannulated Cancellous Screws in the Treatment of Vertical Femoral Neck Fractures: Clinical Observation and Finite Element Analysis,” Biomedical Engineering Online 22, no. 1 (2023): 20.

[15]

P. Rego, V. Mascarenhas, D. Collado, A. Coelho, L. Barbosa, and R. Ganz, “Arterial Topographic Anatomy Near the Femoral Head-Neck Perforation With Surgical Relevance,” Journal of Bone and Joint Surgery. American Volume 99, no. 14 (2017): 1213–1221.

[16]

S. Rawall, K. Bali, B. Upendra, B. Garg, C. S. Yadav, and A. Jayaswal, “Displaced Femoral Neck Fractures in the Young: Significance of Posterior Comminution and Raised Intracapsular Pressure,” Archives of Orthopaedic and Trauma Surgery 132, no. 1 (2012): 73–79.

[17]

N. K. Magu, R. Singla, R. Rohilla, P. Gogna, R. Mukhopadhyay, and A. Singh, “Modified Pauwels' Intertrochanteric Osteotomy in the Management of Nonunion of a Femoral Neck Fracture Following Failed Osteosynthesis,” Bone & Joint Journal 96-B, no. 9 (2014): 1198–1201.

[18]

J. J. Yang, L. C. Lin, K. H. Chao, et al., “Risk Factors for Nonunion in Patients With Intracapsular Femoral Neck Fractures Treated With Three Cannulated Screws Placed in Either a Triangle or an Inverted Triangle Configuration,” Journal of Bone and Joint Surgery. American Volume 95, no. 1 (2013): 61–69.

[19]

X. Sun, Z. Han, D. Cao, et al., “Finite Element Analysis of Six Internal Fixations in the Treatment of Pauwels Type III Femoral Neck Fracture,” Orthopaedic Surgery 16, no. 7 (2024): 1695–1709.

[20]

X. Jiang, K. Liang, G. Du, Y. Chen, Y. Tang, and K. Geng, “Biomechanical Evaluation of Different Internal Fixation Methods Based on Finite Element Analysis for Pauwels Type III Femoral Neck Fracture,” Injury 53, no. 10 (2022): 3115–3123.

[21]

J. Li, P. Yin, L. Zhang, H. Chen, and P. Tang, “Medial Anatomical Buttress Plate in Treating Displaced Femoral Neck Fracture a Finite Element Analysis,” Injury 50, no. 11 (2019): 1895–1900.

[22]

L. Zhou, J. Lin, A. Huang, et al., “Modified Cannulated Screw Fixation in the Treatment of Pauwels Type III Femoral Neck Fractures: A Biomechanical Study,” Clinical Biomechanics 74 (2020): 103–110.

[23]

T. Shi, R. Liang, M. Pan, et al., “Clinical Analysis of Minimally Invasive Treatment of Femoral Neck Fracture With Locking Plate and Cannulated Screw,” Modern Diagnosis and Treatment 27, no. 24 (2016): 4596–4597.

[24]

Q. Huang, C. Zhang, H. Bai, et al., “Biomechanical Evaluation of Two Modified Intramedullary Fixation System for Treating Unstable Femoral Neck Fractures: A Finite Element Analysis,” Frontiers in Bioengineering and Biotechnology 11 (2023): 1116976, https://doi.org/10.3389/fbioe.2023.1116976.

[25]

K. Ding, Y. Zhu, Y. Zhang, et al., “Proximal Femoral Bionic Nail—A Novel Internal Fixation System for the Treatment of Femoral Neck Fractures: A Finite Element Analysis,” Frontiers in Bioengineering and Biotechnology 11 (2023): 1297507, https://doi.org/10.3389/fbioe.2023.1297507.

[26]

C. H. Jung, Y. Cha, H. S. Yoon, et al., “Mechanical Effects of Surgical Variations in the Femoral Neck System on Pauwels Type III Femoral Neck Fracture: A Finite Element Analysis,” Bone & Joint Research 11, no. 2 (2022): 102–111, https://doi.org/10.1302/2046-3758.112.BJR-2021-0282.R1.

[27]

R. Zdero, A. Djuricic, and E. H. Schemitsch, “Mechanical Properties of Synthetic Bones Made by Synbone: A Review,” Journal of Biomechanical Engineering 145, no. 12 (2023): 121003.

[28]

A. D. Brown, J. B. Walters, Y. X. Zhang, M. Saadatfar, J. P. Escobedo-Diaz, and P. J. Hazell, “The Mechanical Response of Commercially Available Bone Simulants for Quasi-Static and Dynamic Loading,” Journal of the Mechanical Behavior of Biomedical Materials 90 (2019): 404–416.

[29]

C. Nan, Y. Liu, D. Zhang, et al., “Mechanical Analysis of Modified Femoral Neck System in the Treatment of Osteoporotic Femoral Neck Fractures,” BMC Musculoskeletal Disorders 25, no. 1 (2024): 789.

[30]

J. A. M. Guimarães, L. R. Rocha, T. H. Noronha Rocha, et al., “Vertical Femoral Neck Fractures in Young Adults: A Closed Fixation Strategy Using a Transverse Cancellous Lag Screw,” Injury 48, no. Suppl 4 (2017): S10–S16.

[31]

Q. Dong, Z. Han, Y. G. Zhang, X. Sun, and X. L. Ma, “Comparison of Transverse Cancellous Lag Screw and Ordinary Cannulated Screw Fixations in Treatment of Vertical Femoral Neck Fractures,” Orthopaedic Surgery 11, no. 4 (2019): 595–603.

[32]

R. B. Molnar and M. L. Routt, Jr., “Open Reduction of Intracapsular Hip Fractures Using a Modified Smith-Petersen Surgical Exposure,” Journal of Orthopaedic Trauma 21, no. 7 (2007): 490–494.

[33]

V. Giordano, D. D. Alves, R. P. Paes, et al., “The Role of the Medial Plate for Pauwels Type III Femoral Neck Fracture: A Comparative Mechanical Study Using Two Fixations With Cannulated Screws,” Journal of Experimental Orthopaedics 6, no. 1 (2019): 18.

[34]

J. E. Brattgjerd, M. Loferer, S. Niratisairak, H. Steen, and K. Strømsøe, “Increased Torsional Stability by a Novel Femoral Neck Locking Plate. The Role of Plate Design and Pin Configuration in a Synthetic Bone Block Model,” Clinical Biomechanics (Bristol, Avon) 55 (2018): 28–35.

[35]

Z. Ma, S. Wu, J. Wang, et al., “Minimally Invasive Open Reduction Combined With Proximal Femoral Hollow Locking Plate in the Treatment of Pauwells Type III Femoral Neck Fracture,” Journal of Trauma and Surgery 23, no. 1 (2021): 41–44.

[36]

Y. Ye, K. Chen, K. Tian, W. Li, C. Mauffrey, and D. J. Hak, “Medial Buttress Plate Augmentation of Cannulated Screw Fixation in Vertically Unstable Femoral Neck Fractures: Surgical Technique and Preliminary Results,” Injury 48, no. 10 (2017): 2189–2193.

[37]

C. P. Flint, “X. The Operative Treatment of Fracture of the Neck of the Femur in Adults,” Annals of Surgery 48, no. 5 (1908): 729–747.

[38]

E. N. Kubiak, M. J. Beebe, K. North, R. Hitchcock, and M. Q. Potter, “Early Weight Bearing After Lower Extremity Fractures in Adults,” Journal of the American Academy of Orthopaedic Surgeons 21, no. 12 (2013): 727–738.

[39]

D. W. Flowers, E. McCallister, R. Christopherson, and E. Ware, “The Safety and Effectiveness of Early, Progressive Weight Bearing and Implant Choice After Traumatic Lower Extremity Fracture: A Systematic Review,” Bioengineering 9, no. 12 (2022): 750.

[40]

S. Boraiah, O. Paul, S. Hammoud, M. J. Gardner, D. L. Helfet, and D. G. Lorich, “Predictable Healing of Femoral Neck Fractures Treated With Intraoperative Compression and Length-Stable Implants,” Journal of Trauma 69, no. 1 (2010): 142–147.

[41]

J. H. Kalsbeek, M. F. van Donkelaar, P. Krijnen, W. H. Roerdink, R. de Groot, and I. B. Schipper, “What Makes Fixation of Femoral Neck Fractures Fail? A Systematic Review and Meta-Analysis of Risk Factors,” Injury 54, no. 2 (2023): 652–660.

[42]

H. Palm, K. Gosvig, M. Krasheninnikoff, S. Jacobsen, and P. Gebuhr, “A New Measurement for Posterior Tilt Predicts Reoperation in Undisplaced Femoral Neck Fractures: 113 Consecutive Patients Treated by Internal Fixation and Followed for 1 Year,” Acta Orthopaedica 80, no. 3 (2009): 303–307.

[43]

K. Luttrell, M. Beltran, and C. A. Collinge, “Preoperative Decision Making in the Treatment of High-Angle "Vertical" Femoral Neck Fractures in Young Adult Patients. An Expert Opinion Survey of the Orthopaedic Trauma Association's (OTA) Membership,” Journal of Orthopaedic Trauma 28, no. 9 (2014): e221–e225.

[44]

M. Panteli, P. Rodham, and P. V. Giannoudis, “Biomechanical Rationale for Implant Choices in Femoral Neck Fracture Fixation in the Non-Elderly,” Injury 46, no. 3 (2015): 445–452.

[45]

Y. Z. Zhang, Y. Lin, C. Li, et al., “A Comparative Analysis of Femoral Neck System and Three Cannulated Screws Fixation in the Treatment of Femoral Neck Fractures: A Six-Month Follow-Up,” Orthopaedic Surgery 14, no. 4 (2022): 686–693.

[46]

O. Filipov, “Biplane Double-Supported Screw Fixation (F-Technique): A Method of Screw Fixation at Osteoporotic Fractures of the Femoral Neck,” European Journal of Orthopaedic Surgery and Traumatology 21, no. 7 (2011): 539–543.

[47]

O. Filipov, K. Stoffel, B. Gueorguiev, and C. Sommer, “Femoral Neck Fracture Osteosynthesis by the Biplane Double-Supported Screw Fixation Method (BDSF) Reduces the Risk of Fixation Failure: Clinical Outcomes in 207 Patients,” Archives of Orthopaedic and Trauma Surgery 137, no. 6 (2017): 779–788.

[48]

O. Filipov and B. Gueorguiev, “Unique Stability of Femoral Neck Fractures Treated With the Novel Biplane Double-Supported Screw Fixation Method: A Biomechanical Cadaver Study,” Injury 46, no. 2 (2015): 218–226.

[49]

J. Li, Z. Zhao, P. Yin, L. Zhang, and P. Tang, “Comparison of Three Different Internal Fixation Implants in Treatment of Femoral Neck Fracture—A Finite Element Analysis,” Journal of Orthopaedic Surgery and Research 14, no. 1 (2019): 106, https://doi.org/10.1186/s13018-019-1148-3.

[50]

S. Samsami, S. Saberi, S. Sadighi, and G. Rouhi, “Comparison of Three Fixation Methods for Femoral Neck Fracture in Young Adults: Experimental and Numerical Investigations,” Journal of Medical and Biological Engineering 35, no. 5 (2015): 566–579.

[51]

R. K. Rajnish, P. Kumar, A. Srivastava, et al., “Femoral Neck Fracture Fixation in Rhombic Versus Inverted Triangle Configuration in Young Adults: A Systematic Review,” Journal of Clinical Orthopaedics and Trauma 53 (2024): 102471.

[52]

S. A. Gümüştaş, H. B. Tosun, İ. Ağır, M. M. Orak, T. Onay, and G. Okçu, “Influence of Number and Orientation of Screws on Stability in the Internal Fixation of Unstable Femoral Neck Fractures,” Acta Orthopaedica et Traumatologica Turcica 48, no. 6 (2014): 673–678.

[53]

Y. Zhou, Z. Li, K. Lao, et al., “Femoral Neck System vs. Cannulated Screws on Treating Femoral Neck Fracture: A Meta-Analysis and System Review,” Frontiers in Surgery 10 (2023): 1224559. Published 2023 Jul 18.

[54]

H. Chung, Y. Kim, I. Kook, J. W. Kwak, and K. T. Hwang, “Comparative Short-Term Outcomes of Femoral Neck System (FNS) and Cannulated Screw Fixation in Patients With Femoral Neck Fractures: A Multicenter Study,” Clinics in Orthopedic Surgery 16, no. 2 (2024): 184–193.

[55]

M. Niemann, T. Maleitzke, M. Jahn, et al., “Restoration of Hip Geometry After Femoral Neck Fracture: A Comparison of the Femoral Neck System (FNS) and the Dynamic Hip Screw (DHS),” Life 13, no. 10 (2023): 2073.

[56]

Z. Wang, W. Zhang, C. Liu, et al., “Enhanced External Counter Pulsation-Assisted Cannulated Screw Fixation Promoted Femoral Neck Fracture Healing: A Pilot Randomized Controlled Trial,” BMC Musculoskeletal Disorders 27, no. 1 (2025): 11.

[57]

K. Stoffel, I. Zderic, F. Gras, et al., “Biomechanical Evaluation of the Femoral Neck System in Unstable Pauwels III Femoral Neck Fractures: A Comparison With the Dynamic Hip Screw and Cannulated Screws,” Journal of Orthopaedic Trauma 31, no. 3 (2017): 131–137.

[58]

C. Schopper, I. Zderic, J. Menze, et al., “Higher Stability and More Predictive Fixation With the Femoral Neck System Versus Hansson Pins in Femoral Neck Fractures Pauwels II,” Journal of Orthopaedic Translation 24 (2020): 88–95.

[59]

X. Q. Zhou, Z. Q. Li, R. J. Xu, et al., “Comparison of Early Clinical Results for Femoral Neck System and Cannulated Screws in the Treatment of Unstable Femoral Neck Fractures,” Orthopaedic Surgery 13, no. 6 (2021): 1802–1809.

[60]

Z. Fan, H. Su, L. Zhou, et al., “Finite Element Analysis of Novel Femoral Neck System for Unstable Femoral Neck Fractures,” Chinese Journal of Tissue Engineering Research 25, no. 15 (2021): 2321–2328.

[61]

C. Nan, L. Ma, Y. Liang, Y. Li, and Z. Ma, “Mechanical Effects of Sagittal Variations on Pauwels Type III Femoral Neck Fractures Treated With Femoral Neck System (FNS),” BMC Musculoskeletal Disorders 23, no. 1 (2022): 1045.

[62]

H. Yin, Z. Pan, and H. Jiang, “Is Dynamic Locking Plate (Targon FN) a Better Choice for Treating of Intracapsular Hip Fracture? A Meta-Analysis,” International Journal of Surgery 52 (2018): 30–34.

Rights & permissions

2026 The Author(s). Orthopaedic Surgery published by Tianjin Hospital and John Wiley & Sons Australia, Ltd.

PDF (3947KB)

0

Accesses

0

Citation

Detail

Sections
Recommended

/

〈 〉