Noninvasive photoacoustic measurement of absorption coefficient using internal light irradiation of cylindrical diffusing fiber

Dong-qing Peng , Li-li Zhu , Zhi-fang Li , Hui Li

Optoelectronics Letters ›› 2017, Vol. 13 ›› Issue (5) : 367 -371.

PDF
Optoelectronics Letters ›› 2017, Vol. 13 ›› Issue (5) :367 -371. DOI: 10.1007/s11801-017-7130-6
Article
research-article
Noninvasive photoacoustic measurement of absorption coefficient using internal light irradiation of cylindrical diffusing fiber
Author information +
History +
PDF

Abstract

Absorption coefficient of biological tissue is an important parameter in biomedicine, but its determination remains a challenge. In this paper, we propose a method using focusing photoacoustic imaging technique and internal light irradiation of cylindrical diffusing fiber (CDF) to quantify the target optical absorption coefficient. Absorption coefficients for ink absorbers are firstly determined through photoacoustic and spectrophotometric measurements at the same excitation, which demonstrates the feasibility of this method. Also, the optical absorption coefficients of ink absorbers with several concentrations are measured. Finally, the two-dimensional scanning photoacoustic image is obtained. Optical absorption coefficient measurement and simultaneous photoacoustic imaging of absorber non-invasively are the typical characteristics of the method. This method can play a significant role for non-invasive determination of blood oxygen saturation, the absorption-based imaging and therapy.

Cite this article

Download citation ▾
Dong-qing Peng, Li-li Zhu, Zhi-fang Li, Hui Li. Noninvasive photoacoustic measurement of absorption coefficient using internal light irradiation of cylindrical diffusing fiber. Optoelectronics Letters, 2017, 13(5): 367-371 DOI:10.1007/s11801-017-7130-6

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Xu M, Wang LV. Review of Scientific Instruments. 2006, 77: 041101

[2]

Zhang T, Wang C, Weng X-f, Wei X-b. Journal of Optoelectronics·Laser. 2015, 26: 2241

[3]

Salehi HS, Kumavor PD, Li H, Alqasemi U, Wang TH, Xu C, Zhu Q. Photoacoustics. 2015, 3: 114

[4]

Kuniyil Ajith Singh M, Parameshwarappa V, Hendriksen E, Steenbergen W, Manohar S. Journal of Biomedical Optics. 2016, 21: 120501

[5]

Hirasawa T, Fujita M, Okawa S, Kushibiki T, Ishihara M. Applied Optics. 2013, 52: 8562

[6]

Lin L, Yao J, Li L, Wang LV. Journal of Biomedical Optics. 2016, 21: 061002

[7]

Wang Y, Wang R. Physics in Medicine Biology. 2008, 53: 6167

[8]

Yuan Z, Wang Q, Jiang H. Optics Express. 2007, 15: 18076

[9]

Yuan Z, Jiang H. Phiols. Transact. A Math. Phys. Eng. Sci.. 2009, 367: 3043

[10]

Li X, Jiang H. Physics in Medicine & Biology. 2013, 58: 999

[11]

Hirasawa T, Fujita M, Okawa S, Kushibiki T, Ishihara M. Proceedings of SPIE 8581. 2013

[12]

Hirasawa T, Okawa S, Fujita M, Kushibiki T, Ishihara M. Quantification of Optical Attenuation Coefficient Based on Continuous Wavelet Transform of Photoacoustic Signals Measured by a Focused Broadband Acoustic Sensor. Conference on Photons Plus Ultrasound: Imaging and Sensing. 2014

[13]

Priya M, Satish Rao BS, Ray S, Mahato KK. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2014, 127: 85

[14]

Cox BT, Arridge SR, Kostli KP, Beard PC. Proceedings of SPIE. 2005, 49: 5697

[15]

Cox BT, Arridge SR, Kostli KP, Beard PC. Applied Optics. 2006, 45: 1866

[16]

Xie W-m, Li H, Li Z-f, Liu H-q. Laser & Optoelectronics Progress. 2009, 46: 103

[17]

Li Z, Li H, Zeng Z, Xie W, Chen W. Journal of Biomedical Optics. 2012, 17: 061216

[18]

Li C, Wang L V. Physics Medicine & Biology. 2009, 54: R59

[19]

Irisawa K, Hirasawa T, Hirota K, Tsujita K, Ishihara M. Proceedings of SPIE 8223. 2012

[20]

Guo Z, Li L, Wang LV. Medical Physics. 2009, 36: 4084

[21]

Peng D-q, Xie W-m, Wu S-l, Tang J-m, Li Z-f, Li H. Acta. Phys. Sin.. 2015, 64: 207801

PDF

165

Accesses

0

Citation

Detail

Sections
Recommended

/