Biological reaction signal enhancement in porous silicon Bragg mirror based on quantum dots fluorescence

Yan-yu Li , Zhen-hong Jia , Jia-jia Wang , Chang-wu Lü

Optoelectronics Letters ›› : 172 -174.

PDF
Optoelectronics Letters ›› :172 -174. DOI: 10.1007/s11801-017-7034-5
Article

Biological reaction signal enhancement in porous silicon Bragg mirror based on quantum dots fluorescence

Author information +
History +
PDF

Abstract

In this paper, we mainly study the preparation of an optical biosensor based on porous silicon (PSi) Bragg mirror and its feasibility for biological detection. The quantum dot (QD) labeled biotin was pipetted onto streptavidin functionalized PSi Bragg mirror samples, the affinity reaction between QD labeled biotin and streptavidin in PSi occurred, so the QDs were indirectly connected to the PSi. The fluorescence of QD enhanced the signal of biological reactions in PSi. The performance of the sensor is verified by detecting the fluorescence of the QD in PSi. Due to the fluorescence intensity of the QDs can be enhanced by PSi Bragg mirror, the sensitivity of the PSi optical biosensor will be improved.

Cite this article

Download citation ▾
Yan-yu Li, Zhen-hong Jia, Jia-jia Wang, Chang-wu Lü. Biological reaction signal enhancement in porous silicon Bragg mirror based on quantum dots fluorescence. Optoelectronics Letters 172-174 DOI:10.1007/s11801-017-7034-5

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

LinV. S., MoteshareiK., DancilK. P., SailorM. J., GhadiriM. R.. Science, 1997, 278: 840

[2]

Xiao-yiL., Guo-dongL., Jia-qingM.O., LiangX.U., Zhen-hongJ.I.A.. Optoelectronics Letters, 2016, 12: 478

[3]

SteinN. E., HamelersH. V. M., BuismanC. N. J.. Sensors & Actuators B Chemical, 2012, s171–172: 816

[4]

NiuS., ZhaoM., HuL., ZhangS.. Sensors & Actuators B Chemical, 2008, 135: 200

[5]

YakovlevaM., BhandS., DanielssonB.. Analytica Chimica Acta, 2013, 766: 1

[6]

GaurG., KoktyshD. S., WeissS. M.. Advanced Functional Materials, 2013, 23: 3604

[7]

JenieS. N., Prieto-SimonB., VoelckerN. H.. Biosensors & Bioelectronics, 2015, 74: 637

[8]

LedentsovN. N., UstinovV. M., ShchukinV. A., Kop’EvP. S., AlferovZ. I., BimbergD.. Semiconductors, 1998, 32: 343

[9]

MidgettA. G., HillhouseH. W., HughesB. K., NozikA. J., BeardM. C.. Journal of Physical Chemistry C, 2010, 114: 17486

[10]

LordS. J., LeeH. D., MoernerW. E.. Analytical Chemistry, 2010, 82: 2192

[11]

DorfnerD. F., HürlimannT., AbstreiterG., FinleyJ. J.. Applied Physics Letters, 2007, 91: 4648

[12]

MoJ. Q., JiangJ., ZhaiZ. G., ShiF. G., JiaZ. H.. Optoelectronics Letters, 2017, 13: 10

[13]

GaurG., KoktyshD., WeissS. M.. Mrs Online Proceeding Library, 2011, 1301: 463

[14]

LiuC., JiaZ., LvX., LvC., ShiF.. Physica B Condensed Matter, 2014, 457: 263

[15]

ZimbronM. J.. Zimbron Malcolm Jeremy, 2012,

[16]

ReyesF. D., RomeroJ. M. F., CastroM. D. L. D.. Analytica Chimica A cta, 2001, 436: 109

PDF

84

Accesses

0

Citation

Detail

Sections
Recommended

/