A facile surface plasmon resonance (SPR) chip is developed for small molecule determination and analysis. The SPR chip was prepared based on a self assembling principle, in which the modified bovine serum albumin (BSA) was directly self-assembled onto the bare gold surface. The surface morphology of the chip with the modified BSA was investigated by atomic force microscopy (AFM) and its optical properties were characterized. The surface binding capacity of the bare facile SPR chip with a uniform morphology is 8 times of that of the bare control SPR chip. Based on the experiments of immune reaction between cortisol antibody and cortisol derivative, the sensitivity of the facile SPR chip with the modified BSA is much higher than that of the control SPR chip with the un-modified BSA. The facile SPR chip has been successfully used to detect small molecules. The lowest detection limit is 5 ng/mL with a linear range of 5—100 ng/mL for cortisol analysis. The novel facile SPR chip can also be applied to detect other small molecules.
Cite this article
Download citation ▾
Xing Chen, Lu-lu Zhang, Da-fu Cui.
Fabrication and characterization of SPR chips with the modified bovine serum albumin.
Optoelectronics Letters 93-96 DOI:10.1007/s11801-016-5248-6
| [1] |
KandaV., KariukiJ. K., HarrisonD. J., McDermottM. T.. Analytical Chemistry, 2004, 76: 7257
|
| [2] |
MingL., CushingS. K., WuN.. Analyst, 2014, 140: 386
|
| [3] |
ChiL. W., OlivoM.. Plasmonics, 2014, 9: 809
|
| [4] |
LiZ., YuX.-t., QinC.-f., CaoX.-d., PanH.-f., XuJ.-h.. J. Optoelectron. Laser, 2015, 26: 1423
|
| [5] |
JohnM.. Sensors, 2010, 10: 7323
|
| [6] |
de MolN. J.. Methods in Molecular Biology, 2010, 627: 101
|
| [7] |
LiuC., CuiD., HuiL.. Biosensors & Bioelectronics, 2010, 26: 255
|
| [8] |
KimS. J., GobiK. V., TanakaH., ShoyamacY., MiuraN.. Sensors & Actuators B Chemical, 2008, 130: 281
|
| [9] |
WijayaE., LenaertsC., MaricotS., HastaninJ., HabrakenS., VilcotJ., BoukherroubR., SzuneritsS.. Current Opinion in Solid State Materials Science, 2011, 15: 208
|
| [10] |
QiJ.-x.. J. Optoelectron. Laser, 2014, 25: 282
|
| [11] |
DongJ., LiuJ.-h., YanX.-w., ZhangW.-w., ZhangB.. J. Optoelectron. Laser, 2015, 26: 1222
|
| [12] |
CuiD. F., CaiH. Y., WangJ. B.. High Throughput Multi Parameter Image Surface Plasmon Resonance Test Instrument, 2007,
|
| [13] |
YuQ., ChenS., TaylorA. D., HomolaJ., HockB., JiangS.. Sensors & Actuators B Chemical, 2005, 107: 193
|
| [14] |
al’AbsiM., ArnettD. K.. Biomed. Pharmacother, 2000, 54: 234
|
| [15] |
KnutssonU., DahlgrenJ., MarcusC., RosbergS., BronnegardM., StiernaP.. J. Clin. Endocrinol. Metab., 1997, 82: 536
|
Just Accepted
This article has successfully passed peer review and final editorial review, and will soon enter typesetting, proofreading and other publishing processes. The currently displayed version is the accepted final manuscript. The officially published version will be updated with format, DOI and citation information upon launch. We recommend that you pay attention to subsequent journal notifications and preferentially cite the officially published version. Thank you for your support and cooperation.