PDF
Abstract
This paper presents a surface plasmon resonance (SPR) imaging system based on angular modulation (AM) and intensity measurement (IM) together to avoid the mechanical errors of the angle scanning device. The SPR resonant angle was found by angular scanning method and then the light intensity changes were collected at a fixed incident angle. Glycerol gradient solution (0%, 1%, 2%, 3% (weight percentage) glycerol dissolved in water) experiments were conducted, which indicate that the best fixed angle location is the middle of the linear range of SPR absorption peak and the central area signals are more uniform than those of the border areas. The sensitivity differences of different areas of SPR images are studied, and an optimized algorithm is developed.
Cite this article
Download citation ▾
Lu-lu Zhang, Xing Chen, Da-fu Cui.
Performance of surface plasmon resonance imaging system based on angular modulation and intensity measurement.
Optoelectronics Letters 226-228 DOI:10.1007/s11801-016-5247-7
| [1] |
LIUK.-x.. Journal of Optoelectronics·Laser, 2015, 26: 199
|
| [2] |
LIZ., YUX.-t., QINC.-f., CAOX.-d., PANH.-f., XUJ.-h.. Journal of Optoelectronics ·Laser, 2015, 26: 1423
|
| [3] |
PiliarikM., ParovaL., HomolaJ.. Biosensors and Bioelectronics, 2009, 24: 1399
|
| [4] |
JeongE. J., JeongY. S., ParkK., YiS. Y., AhnJ., ChungS. J., KimM., ChungB.H.. Journal of Biotechnology, 2008, 135: 16
|
| [5] |
LiH., CaiH. Y., ChenX., SunJ. H., ZhangL. L., CuiD. F.. Analytical Letters, 2010, 43: 499
|
| [6] |
WuH., LiH., ChuaF. Z. H., LiS. F. Y.. Sensors and Actuators B, 2013, 178: 541
|
| [7] |
TsaiW., LiI.. Sensors and Actuators B, 2009, 136: 8
|
| [8] |
WegnerG. J., WarkA. W., LeeH. J., CodnerE., SaekiT., FangS., CornR. M.. Anal. Chem., 2004, 76: 5677
|
| [9] |
YanaseY., HiragunT., KanekoS., GouldH. J., GreavesM. W., HideM.. Biosensors and Bioelectronics, 2010, 26: 674
|
| [10] |
StojanovićI., SchasfoortR. B. M., TerstappenL. W. M. M.. Biosensors and Bioelectronics, 2014, 52: 36
|
| [11] |
RothenhauslerB., KnollW.. Nature, 1988, 332: 615
|
| [12] |
NandA., SinghV., PérezJ. B., TyagiD., ChengZ., ZhuJ.. Analytical Biochemistry, 2014, 464: 30
|
| [13] |
ZhangL. L., ChenX., WeiH. T., LiH., SunJ. H., CaiH. Y., ChenJ. L., CuiD. F.. Review of Scientific Instruments, 2013, 84: 085005
|
| [14] |
ZhangH., SongD. Q., GaoS., ZhangH. Q., ZhangJ., SunY.. Talanta, 2013, 115: 857
|
| [15] |
DouF. Y., WangP., YuX. L.. Journal of Tsinghua University (Science and Technology), 2014, 54: 202
|
Just Accepted
This article has successfully passed peer review and final editorial review, and will soon enter typesetting, proofreading and other publishing processes. The currently displayed version is the accepted final manuscript. The officially published version will be updated with format, DOI and citation information upon launch. We recommend that you pay attention to subsequent journal notifications and preferentially cite the officially published version. Thank you for your support and cooperation.