Experimental study on high-power LEDs integrated with micro heat pipe

Cong-ming LI, Chuan-peng Zhou, Yi Luo, Mohammad Hamidnia, Xiao-dong Wang, Bo You

Optoelectronics Letters ›› , Vol. 12 ›› Issue (1) : 31-34.

Optoelectronics Letters ›› , Vol. 12 ›› Issue (1) : 31-34. DOI: 10.1007/s11801-016-5231-2
Article

Experimental study on high-power LEDs integrated with micro heat pipe

Author information +
History +

Abstract

Micro heat pipe (MHP) is applied to implement the efficient heat transfer of light emitting diode (LED) device. The fabrication of MHP is based on micro-electro-mechanical-system (MEMS) technique, 15 micro grooves were etched on one side of silicon (Si) substrate, which was then packaged with aluminum heat sink to form an MHP. On the other side of Si substrate, three LED chips were fixed by die bonding. Then experiments were performed to study the thermal performance of this LED device. The results show that the LED device with higher filling ratio is better when the input power is 1.0 W; with the increase of input power, the optimum filling ratio changes from 30% to 48%, and the time reaching stable state is reduced; when the input power is equal to 2.5 W, only the LED device with filling ratio of 48% can work normally. So integrating MHP into high-power LED device can implement the effective control of junction temperature.

Keywords

Light Emit Diode / Input Power / Heat Pipe / Proportional Integral Derivative / Filling Ratio

Cite this article

Download citation ▾
Cong-ming LI, Chuan-peng Zhou, Yi Luo, Mohammad Hamidnia, Xiao-dong Wang, Bo You. Experimental study on high-power LEDs integrated with micro heat pipe. Optoelectronics Letters, , 12(1): 31‒34 https://doi.org/10.1007/s11801-016-5231-2

References

[1]
AhnJ., KimD., LeeC. R., BaekB. J.. Materials Research Innovations, 2014, 18: S2-748
CrossRef Google scholar
[2]
ChenK., NarendranN.. Microelectronics Reliability, 2013, 53: 701
CrossRef Google scholar
[3]
ChangC. C., HuangD. S., LinM. T., HorngR. H., LaiC. M.. Microsystem Technologies, 2010, 16: 519
CrossRef Google scholar
[4]
LUX.-y., QIANT.-t., WANGY.-p., LINY., FANGW.. Journal of Optoelectronics·Laser, 2015, 26: 1843
[5]
DENGX., XIAZ.-x., LUOZ.-b., LIY.-j., MAY.. Journal of Optoelectronics·Laser, 2014, 25: 2272
[6]
HsiehJ. C., HuangH. J., ShenS. C.. Microelectronics Reliability, 2012, 52: 1071
CrossRef Google scholar
[7]
DengY. C., QuanZ. H., ZhaoY. H., WangL. C.. Science China Technological Sciences, 2013, 56: 1177
CrossRef Google scholar
[8]
YangK.-S., ChengY.-C., JengM.-S., ChienK.-H., ShyuJ.-C.An Experimental Investigation of Micro Pulsating Heat Pipes8th Annual IEEE International Conference on Nano/Micro Engineered and Molecular Systems, 2013, 869
CrossRef Google scholar
[9]
WangH.-Y., HaoL.-M., ZhaoY.-H., DiaoY.-H.. Journal of Engineering Thermophysics, 2011, 32: 651
[10]
HaoL., ZhaoY., DiaoY., QuanZ.-H.. Journal of Engineering Thermophysics, 2010, 31: 1575
[11]
LuX., HuaZ., LiuM., ChengY.. Science in China Series E: Technological Sciences, 2009, 52: 3527
CrossRef Google scholar
[12]
SheuG.-J., HwuF.-S., TuS.-h., ChenW.-T., ChangJ.-Y., ChenJ.-C.. Proceedings of SPIE, 2005, 5941: 13
CrossRef Google scholar
[13]
KimL., ChoiJ. H., JangS. H., ShinM. W.. Thermochimica Acta, 2007, 455: 21
CrossRef Google scholar
[14]
LiC., LuoY., ZhouC., ShanQ., WangX.. Micro & Nano Letters, 2015, 10: 518
CrossRef Google scholar

This work has been supported by the State Key Development Program for Basic Research of China (No.2011CB013105).

Accesses

Citations

Detail

Sections
Recommended

/