Test method of frequency response based on diamond surface acoustic wave devices
Xi-ming Chen , Bao-he Yang , Xiao-guo Wu , Yi-zhuo Wu
Optoelectronics Letters ›› 2011, Vol. 7 ›› Issue (4) : 291 -293.
Test method of frequency response based on diamond surface acoustic wave devices
In order to reduce the noises affixed to the signals when testing high frequency devices, a single-port test mode (S11) is used to test frequency response of high frequency (GHz) and dual-port surface acoustic wave devices (SAWDs) in this paper. The feasibility of the test is proved by simulating the Fabry-Perot model. The frequency response of the high-frequency dual-port resonant-type diamond SAWD is measured by S11 and the dual-port test mode (S21), respectively. The results show that the quality factor of the device is 51.29 and the 3 dB bandwidth is 27.8 MHz by S11-mode measurement, which is better than the S21 mode, and is consistent with the frequency response curve by simulation.
Frequency Response / Output Port / Frequency Response Curve / Mobile Communication System / Bulk Acoustic Wave
| [1] |
|
| [2] |
|
| [3] |
|
| [4] |
|
| [5] |
|
| [6] |
|
| [7] |
Tam H. Duong, David W. Berning, A. R. Hefner, Jr. and Keyue M. Smedley, IEEE International Ultrasonics Symposium Proceedings, 1240 (2007). |
| [8] |
|
| [9] |
Chen Ximing, Xu Sheng, Ma Jing and Yang Baohe, The 11th National Conference on Optoelectronic Technology and Systems, 12 (2005). (in Chinese) |
| [10] |
|
/
| 〈 |
|
〉 |