Abstract

A novel porous silicon based optical Fabry-Perot cavity structure is prepared as a label-free immunosensor platform for detecting antigen-antibody. The lagurus zona pelluciad 3 (LZP3) and the specificity of the polyclonal anti-LZP3 antibodies are employed in our laboratory as the target and the probe, respectively. Firstly, the antibodies are immobilized to the porous silicon optical cavity using silanization and glutaraldehyde (GA) chemistry. And then, after the antigen-antibody reaction, it is monitored that the red shift of the reflection spectrum of the immunosensor increases with the antigen concentration. This research also plays a potential role for the extensive applications in immunoassay.

Keywords

Reflection Spectrum / Porous Silicon / Optical Cavity / Physica Status Solidus / Refractive Index Layer

Cite this article

Download citation ▾
Xiao-yi Lv, Jia-qing Mo, Yi-xian Tu, Fu-ru Zhong, Tao Jiang, Zhen-hong Jia, Jiang-wei Li, Fu-chun Zhang. Porous silicon optical cavity as an immunosensor platform. Optoelectronics Letters, 2010, 6(4): 314-316 DOI:10.1007/s11801-010-0033-4

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

LinV. S. -Y., MoteshareiK., DancilK.-P. S., SailorM. J., Reza GhadiriM.. Science, 1997, 278: 840

[2]

XueT., LvX.-y., JiaZ.-h., HouS.-b., ZhangF.-c.. Journal of Optoelectronics · Laser, 2008, 19: 1606

[3]

LuX.-y., QingG., XiangM., JiaZ.-h., LiR., ZhongF.-r., LiJ.-w., ZhangF.-c.. Chemical Journal Chinese Universities, 2009, 30: 2381

[4]

AndersonM. A., Tinsley-BownA., AllcockP., PerkinsE. A., SnowP., HollingsM., SmithR. G., ReevesC., SquirrellD. J., NicklinS., CoxT. I.. Physica Status Solidi A, 2003, 197: 528

[5]

ChapronJ., AlekseevS. A., LysenkoV., ZaitsevV. N., BarbierD.. Sensors and Actuators B, 2007, 120: 706

[6]

ChanS., FauchetP. M., LiY., RothbergL. J., MillerB. L.. Physica Status Solidi A, 2000, 182: 541

[7]

DeLouiseL. A., KouP. M., MillerB. L.. Analytical Chemistry, 2005, 77: 3222

[8]

OuyangH., DeLouiseL. A., MillerB. L., FauchetP. M.. Analytical Chemistry, 2007, 79: 1502

[9]

ZhangA. L., ZhuangS. Z., WuD. C., LiY. J., ZhangF. C.. Journal of Molecular Cell Biology, 2009, 42: 186

[10]

FangY.. Journal of Synthetic Crystals, 2008, 37: 243

[11]

WangZ., ZhangJ., XuS. H., WangL., CaoZ., ZhanP., WangZ. L.. J. Phys. D: Appl. Phys., 2007, 40: 4482

[12]

FernandezR. E., BhattacharyaE., ChadhaA.. Applied Surface Science, 2008, 254: 4512

[13]

CanariaC. A., LeesI. N., WunA. W., MiskellyG. M., SailorM. J.. Inorganic Chemistry Communications, 2002, 5: 560

[14]

ChapronJ., AlekseevS. A., LysenkoV., ZaitsevV. N., BarbierD.. Sensors and Actuators B, 2007, 120: 706

[15]

LiH. L., FuA. P., XuD. S., GuoG. L., GuiL. L., TangY. Q.. Langmuir, 2002, 18: 3198

[16]

XuZ., LiuQ., FinchJ. A.. Applied Surface Science, 1997, 120: 269

[17]

De StefanoL., LambertiA., RotirotiL., De StefanoM.. Acta Biomaterialia, 2008, 4: 126

[18]

De TommasiE., De StefanoL., ReaI., Di SarnoV., RotirotiL., ArcariP., LambertiA., SangesC., RendinaI.. Sensors, 2008, 8: 6549

[19]

OuyangH., StriemerC. C., FauchetP. M.. Applied Physics Letters, 2006, 88: 163108

AI Summary AI Mindmap
PDF

110

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/