Experimental Study of Post-heated Steel Reinforced Recycled Concrete Columns Repaired with CFRP

Pu Jia , Jiangfeng Dong , Shucheng Yuan , Qingyuan Wang

Journal of Wuhan University of Technology Materials Science Edition ›› 2018, Vol. 33 ›› Issue (4) : 901 -907.

PDF
Journal of Wuhan University of Technology Materials Science Edition ›› 2018, Vol. 33 ›› Issue (4) : 901 -907. DOI: 10.1007/s11595-018-1911-z
Cementitious Materials

Experimental Study of Post-heated Steel Reinforced Recycled Concrete Columns Repaired with CFRP

Author information +
History +
PDF

Abstract

The mechanical and thermal properties of steel reinforced concrete columns with CFRP reinforcement were examined after exposure to a high temperature of 500 ºC. The concrete made with normal and recycled coarse aggregate (RCA) was fabricated and three different RCA replacement ratios (0, 50%, and 100%) were investigated. The fatigue properties of steel reinforced concrete with RCA and CFRP reinforcement were tested for two million cycles at a frequency of 2.5 Hz. The test results show that the failure of strengthened specimens is mainly caused by rupture of CFRP jacket and buckling of inner section steel reinforcement. However, for the unstrengthened specimen, both of inner steel buckling and core concrete cracking are the main contributors to the damage. The load-bearing capacity, deformation and energy dissipation of the specimens during the fatigue test could be strengthened greatly by CFRP reinforcement. However, the CFRP reinforcement has little influence on the improvement of the stiffness of the specimens, which may be caused by a plastic damage accumulation during the early cycles of fatigue tests. Finally, a static test was conducted on the post-fatigue specimens, the results showed that a large decrease in stiffness was observed for the specimens subjected to high temperature and fatigue, and the fatigue loading had a higher influence on the specimens than the high temperature.

Keywords

recycled concrete column / high temperature / CFRP / fatigue loading

Cite this article

Download citation ▾
Pu Jia, Jiangfeng Dong, Shucheng Yuan, Qingyuan Wang. Experimental Study of Post-heated Steel Reinforced Recycled Concrete Columns Repaired with CFRP. Journal of Wuhan University of Technology Materials Science Edition, 2018, 33(4): 901-907 DOI:10.1007/s11595-018-1911-z

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Ganesh Prabhu G, Sundarraja MC, Kim YY. Compressive Behavior of Circular CFST Columns Externally Reinforced Using CFRP Composites[J]. Thin-Walled Struct., 2015, 87: 139-148.

[2]

Ingham J. Forensic Engineering of Fire-damaged Structures[J]. Proc. Inst. Civ. Eng. -Civ. Eng., 2009, 162(5): 12-17.

[3]

Toutanji H, Han M, Gilbert J, et al. Behavior of Large-scale Rectangular Columns Confined with FRP Composites[J]. J. Compos. Constr., 2010, 14(1): 62-71.

[4]

El Maaddawy T. Post-repair Performance of Eccentrically Loaded RC Columns Wrapped with CFRP Composites[J]. Cem. Concr. Compos., 2008, 30(9): 822-830.

[5]

Tao Z, Yu Q, Zhong YZ. Compressive Behaviour of CFRP-confined Rectangular Concrete Columns[J]. Mag. Concr. Res., 2008, 60(10): 735-745.

[6]

Dong J, Wang Q, Guan Z. Structural Behaviour of RC Beams with External Flexural and Flexural-shear Strengthening by FRP Sheets[J]. Compos. Part B Eng., 2013, 44(1): 604-612.

[7]

Yaqub M, Bailey CG. Repair of Fire Damaged Circular Reinforced Concrete Columns with FRP Composites[J]. Constr. Build Mater., 2011, 25(1): 359-370.

[8]

Yaqub M, Bailey CG. Cross Sectional Shape Effects on the Performance of Post-heated Reinforced Concrete Columns Wrapped with FRP Composites[J]. Compos. Struct., 2011, 93(3): 1103-1117.

[9]

Tao Z, Han LH. Behaviour of Fire-exposed Concrete-filled Steel Tubular Beam Columns Repaired with CFRP Wraps[J]. Thin-Walled Struct., 2007, 45(1): 63-76.

[10]

Yaqub M, Bailey CG, Nedwell P, et al. Strength and Stiffness of Post-heated Columns Repaired with Ferrocement and Fibre Reinforced Polymer Jackets[J]. Compos. Part B Eng., 2013, 44(1): 200-211.

[11]

Marchant EW. A Complete Guide to Fire and Buildings[M]. 1972 London: Medical and Technical Publishing.

[12]

Chaallal O, Boussaha F, Bousselham A. Fatigue Performance of RC Beams Strengthened in Shear with CFRP Fabrics[J]. J. Compos. Constr., 2010, 14(4): 415-423.

AI Summary AI Mindmap
PDF

156

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/