Wear and corrosion properties of Mo surface-modified layer in TiNi alloy prepared by plasma surface alloying

Hongqian Zhang , Zhenxia Wang , Hongyu Yang , Xiaolin Shan , Xiaoping Liu , Shengwang Yu , Zhiyong He

Journal of Wuhan University of Technology Materials Science Edition ›› 2016, Vol. 31 ›› Issue (4) : 910 -917.

PDF
Journal of Wuhan University of Technology Materials Science Edition ›› 2016, Vol. 31 ›› Issue (4) : 910 -917. DOI: 10.1007/s11595-016-1467-8
Metallic Materials

Wear and corrosion properties of Mo surface-modified layer in TiNi alloy prepared by plasma surface alloying

Author information +
History +
PDF

Abstract

In order to improve the wear resistance and restrain nickel release of TiNi alloys, the Mo modified layers on TiNi substrates were obtained using the double glow plasma surface alloying technique. Scanning electron microscopy (SEM), glow discharge optical emission spectroscopy (GDOES) and X-ray diffraction (XRD) were employed to investigate the morphology, composition and structure. Microhardness test and scratch test were performed to analyze the microhardness and coating/substrate adhesion. Tribological and electrochemical behaviors of the Mo modified layers on TiNi were tested by the reciprocating wear instrument and electrochemical measurement system. The Ni concentrations in Hanks’ solution where surface electrochemical tests took place were measured by mass spectrometry. The surface-modified layer contained a Mo deposition layer and a Mo diffusion layer. The X-ray diffraction analysis revealed that the modified layers were composed of Mo, MoTi, MoNi, and Ti2Ni. The microhardnesses of the Mo modified layers treated at 900 °C and 950 °C were 832.8 HV and 762.4 HV, respectively, which was about 3 times the microhardness of the TiNi substrate. Scratch tests indicated that the modified layers possessed good adhesion with the substrate. Compared with as-received TiNi alloy, the modified alloys exhibited significant improvement of wear resistance against Si3N4 with low normal loads during the sliding tests. Mass spectrometry displayed that the Mo alloy layers had successfully inhibited the Ni release into the body.

Keywords

TiNi / plasma surface alloying / Mo modified layer / wear resistance / electrochemistry behavior

Cite this article

Download citation ▾
Hongqian Zhang, Zhenxia Wang, Hongyu Yang, Xiaolin Shan, Xiaoping Liu, Shengwang Yu, Zhiyong He. Wear and corrosion properties of Mo surface-modified layer in TiNi alloy prepared by plasma surface alloying. Journal of Wuhan University of Technology Materials Science Edition, 2016, 31(4): 910-917 DOI:10.1007/s11595-016-1467-8

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Shi P, Geng F, Cheng FT. Preparation of Titania-hydroxyapatite Coating on NiTi Via a Low-temperature Route[J]. Mater. Lett., 2006, 60: 1996-1999.

[2]

Rondelli G. Corrosion Resistance Tests on NiTi Shape Memory Alloy[J]. Biomaterials, 1996, 17: 2003-2008.

[3]

Silbersteinm BM, Gyunter VE. Shape-Memory Implants in Spinal Surgery[M], 2000 Berlin: Springer. 147

[4]

Silberstein B. The Use of a Memory-Shape Staple in Cervical Anterior Fusion(about 100 Human Implantations)[C]. Proceedings of the Second International Conference on Shape Memory and Superelastic Technologies, 1997 167

[5]

Barrett RD, Bishara SE, Quinn JK. Biodegradation of Orthodontic Appliances: Part I, Biodegradation of Nickel and Chromium in Vitro[J]. Am. J. Orthod. Dentofac. Orthoped., 1993, 103: 8-14.

[6]

Peltonen L. Nickel Sensitivity in the General Population[J]. Contact Dermatitis., 1979, 5: 27-32.

[7]

Cempel M, Nikel G. Nickel: A Review of Its Sources and Environmental Toxicology[J]. Pol. J. Environ. Stud., 2006, 15: 375-382.

[8]

Denkhausa E, Salnikow K. Nickel Essentiality, Toxicity, and Carcinogenicity[J]. Crit. Rev. Oncol. Hematol., 2002, 42: 35-56.

[9]

Heintz C, Riepe G, Birken L, et al. Corroded Nitinol Wires in Explanted Aortic Endografts: An Important Mechanism of Failure[J]. J. Endovasc. Ther., 2001, 8: 248-253.

[10]

Gu YW, Tay BY, Lim CS, et al. Biomimetic Deposition of Apatite Coating on Surface-modified NiTi Alloy[J]. Biomaterials, 2005, 26: 6916-6923.

[11]

Li Y, Wei SB, Cheng XQ, et al. Corrosion Behavior and Surface Characterization of Tantalum Implanted TiNi Alloy[J]. Surf. Coat. Technol., 2008, 202: 3017-3022.

[12]

Ahmadi H, Nouri M. Effects of Yttrium Addition on Microstructure, Hardness and Resistance to Wear and Corrosive Wear of TiNi Alloy[J]. J. Mater. Sci. Technol., 2011, 27: 851-855.

[13]

Ahmed RA, Fadl-allah SA, El-Bagoury N, et al. Improvement of Corrosion Resistance and Antibacterial Effect of NiTi Orthopedic Materials by Chitosan and Gold Nanoparticles[J]. Appl. Surf. Sci., 2014, 292: 390-399.

[14]

Feng X, Sui JH, Cai W, et al. Improving wear Resistance of TiNi Matrix Composites Reinforced by Carbon Nanotubes and in situ TiC[J]. Scripta Mater., 2011, 64: 824-827.

[15]

Ng KW, Man HC, Yue TM. Corrosion and Wear Properties of Laser Surface Modified NiTi with Mo and ZrO2[J]. Appl. Surf. Sci., 2008, 254: 6725-6730.

[16]

Xu Z. Method and Apparatus for Introducing Normally Solid Materials into Substrate Surface[P], 1985

[17]

Lin NM, Xie FQ, Zhou J, et al. Microstructures and Wear Resistance of Chromium Coatings on P110 Steel Fabricated by Pack Cementation[J]. J. Cent. South Univ. Technol., 2010, 17: 1155-1162.

[18]

Cassar G, Avelar-Batista W J, Banfield S, et al. A Study of the Reciprocating-sliding Wear Performance of Plasma Surface Treated Titanium Alloy[J]. Wear, 2010, 269: 60-70.

[19]

Stolarski TA, Tobe S. The Effect of Spraying Distance on Wear Resistance of Molybdenum Coatings[J]. Wear, 2001, 249: 1096-1102.

[20]

Laribi M, Vannes AB, Treheux D. Study of Mechanical Behavior of Molybdenum Coating Using Sliding Wear and Impact Tests[J]. Wear, 2007, 262: 1330-1336.

[21]

Lin NM, Xie FQ, Zhong T, et al. Influence of Adding Various Rare Earths on Microstructures and Corrosion Resistance of Chromizing Coatings Prepared Via Pack Cementation on P110 Steel[J]. Journal of Rare Earths, 2010, 28: 301-304.

[22]

Liang J, Bala SP, Blawert C, et al. Electrochemical Corrosion Behaviour of Plasma Electrolytic Oxidation Coatings on AM50 Magnesium Alloy Formed in Silicate and Phosphate Based Electrolytes[J]. Electrochim. Acta., 2009, 54: 3842-3850.

[23]

Yang HY, Guo XW, Wu GH, et al. Continuous Intermetallic Compounds Coatings on AZ91D Mg Alloy Fabricated by Diffusion Reaction of Mg-Al Couples[J]. Surf. Coat. Technol., 2011, 205: 2907-2913.

[24]

Ahn SH, Lee JH, Kim HG, et al. A Study on the Quantitative Determination of Through-coating Porosity in PVD-grown Coatings[J]. Appl. Surf. Sci., 2004, 233: 105-114.

AI Summary AI Mindmap
PDF

102

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/