Dynamic mechanical property of hybrid fiber reinforced concrete(HFRC)
Zhigang Ren , Meng Chen , Zhe’an Lu , Weiguo Xu
Journal of Wuhan University of Technology Materials Science Edition ›› 2012, Vol. 27 ›› Issue (4) : 783 -788.
Dynamic mechanical property of hybrid fiber reinforced concrete(HFRC)
The uniaxial compressive response of steel-polypropylene hybrid fiber reinforced concrete (HFRC) and steel fiber-reinforced concrete (SFRC) was analyzed under high strain rate loading with a 74 mm diameter split Hopkinson pressure bar (SHPB). The experimental investigation focused on recorded data and resulted in distinguishing the strain rate that mobilized different ductility of steel-polypropylene hybrid fiber reinforced concrete (HFRC) and steel fiber-reinforced concrete (SFRC). 64 specimens of HFRC and SFRC with higher static compressive strength were tested at the strain rates changing from 20 to 120 s−1. The static compressive strength and dynamic stress-strain curves of the two materials were obtained at 4 different strain rates and the failure stress, and peak strain and peak toughness were also analyzed. The results show that HFRC has quite good dynamic mechanical property and clear strain-rate effect, and the failure mechanism of HFRC and SFRC was also compared based on the specimens’ failure modes in static and dynamic compressive tests.
HFRC / SFRC / compression property / SHPB / strain rate
| [1] |
|
| [2] |
|
| [3] |
|
| [4] |
|
| [5] |
|
| [6] |
|
| [7] |
|
| [8] |
GB/T 50081-2002. Ministry of Construction of People’s Republic of China. Mechanical Properties of Ordinary Concrete Test Method Standards [S]. |
| [9] |
|
| [10] |
|
| [11] |
|
| [12] |
|
| [13] |
|
/
| 〈 |
|
〉 |