Determination of trace impurity elements in MnZn ferrite powder by direct current glow discharge mass spectrometry

Liang Fu , Jun-cai Ma , Shu-yun Shi

Journal of Central South University ›› 2018, Vol. 25 ›› Issue (7) : 1590 -1597.

PDF
Journal of Central South University ›› 2018, Vol. 25 ›› Issue (7) : 1590 -1597. DOI: 10.1007/s11771-018-3851-3
Article

Determination of trace impurity elements in MnZn ferrite powder by direct current glow discharge mass spectrometry

Author information +
History +
PDF

Abstract

An analytical method for the determination of 26 impurity elements (such as Li, Be, Na, Mg, Al, Si, P, S, K, Ca, Sc, Ti, V, Cr, Co, Ni, Ga, Ge, Y, Nb, Mo, Ag, Cd, Sb, W and Pb) in MnZn ferrite powder by direct current glow discharge mass spectrometry (GD-MS) was established. MnZn ferrite powder was mixed with copper powder, used as a conductor, and pressed. The effects of MnZn ferrite powder preparation conditions and glow discharge parameters for the sensitivity and stability of signal analysis were investigated. By determining the choice of isotope and the application of the mass resolutions of 4000 (MR, medium resolution) and 10000 (HR, high resolution), mass spectral interference was eliminated. The contents of impurity elements in MnZn ferrite powder was calculated by subtraction after normalizing the total signal of Mn, Zn, Fe, O and Cu. The results showed that the detection limit of 26 kinds of impurity elements was between 0.002 and 0.57 μg/g, and the relative standard deviation (RSD) was between 3.33% and 32.35%. The accuracy of this method was verified by the ICP-MS. The method was simple and practical, which is applied to the determination of impurity elements in MnZn ferrite powder.

Keywords

MnZn ferrite powder / glow discharge mass spectrometry / impurity elements / copper powder

Cite this article

Download citation ▾
Liang Fu, Jun-cai Ma, Shu-yun Shi. Determination of trace impurity elements in MnZn ferrite powder by direct current glow discharge mass spectrometry. Journal of Central South University, 2018, 25(7): 1590-1597 DOI:10.1007/s11771-018-3851-3

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

ShokrollahiH, JanghorbanK. Influence of additives on the magnetic properties, microstructure and densification of Mn-Zn soft ferrites [J]. Materials Science and Engineering B, 2007, 141(3): 91-107

[2]

EbrahimiS A S, MasoudpanahS M, AmiriH, YousefzadehM. Magnetic properties of MnZn ferrite nanoparticles obtained by SHS and sol-gel autocombustion techniques [J]. Ceramics International, 2014, 40(5): 6713-6718

[3]

TsakaloudiV, KogiasG, ZaspalisV T. Process and material parameters towards the design of fast firing cycles for high permeability MnZn ferrites [J]. Journal of Alloys and Compounds, 2014, 588: 222-227

[4]

KogiasG, TsakaloudiV, der ValkP V, ZaspalisV. Improvement of the properties of MnZn ferrite power cores through improvements on the microstructure of the compacts [J]. Journal of Magnetism and Magnetic Materials, 2012, 324(2): 235-241

[5]

ZlatkovB S, MitrovicN S, NikolicM V, MaricicA M, DanningerH, AleksicO S, HalwaxE. Properties of MnZn ferrites prepared by powder injection molding technology [J]. Materials Science and Engineering B, 2010, 175(3): 217-222

[6]

GusarovaT, HofmannT, KipphardtH, VenzagoC, MatschatR, PanneU. Comparison of different calibration strategies for the analysis of zinc and other pure metals by using the GD-MS instruments VG 9000 and element GD [J]. Journal of Analytical Atomic Spectrometry, 2010, 25(3): 314-321

[7]

ZhangJ, ZhouT, TangY, CuiY, LiJin. Determination of relative sensitivity factors of elements in high purity copper by doping-melting and doping-pressed methods using glow discharge mass spectrometry [J]. Journal of Analytical Atomic Spectrometry, 2016, 31(11): 2182-2191

[8]

SchmittS W, VenzagoC, HoffmannB, SivakovV, HofmannT, MichlerJ, ChristiansenS, GamezG. Glow discharge techniques in the chemical analysis of photovoltaic materials [J]. Progress in Photovoltaics: Research and Applications, 2014, 22(3): 371-382

[9]

PlotnikovA, PfeiferJ, RichterS, KipphardtH, HoffmannF. Determination of major nonmetallic impurities in magnesium by glow discharge mass spectrometry with a fast flow source using sintered and pressed powder samples [J]. Analytical and Bioanalytical Chemistry, 2014, 406(29): 7463-7471

[10]

JungS, KimS, HinrichsJ. Determination of trace elements in high purity alumina powder by helium enhanced direct current glow discharge mass spectrometry [J]. Spectrochimica Acta Part B: Atomic Spectroscopy, 2016, 122: 46-51

[11]

SiqinB, QianR, ZhuoS, GaoJ, JinJ, WenZhao. Studies of rare earth elements to distinguish nephrite samples from different deposits using direct current glow discharge mass spectrometry [J]. Journal of Analytical Atomic Spectrometry, 2014, 29(11): 2064-2071

[12]

DongJ, QianR, XiongW, QuH, SiqinB, ZhuoS, JinJ, WenZ, HeP, RobinsonP K. Determination of doping elements of synthetic crystals by direct current glow discharge mass spectrometry [J]. International Journal of Mass Spectrometry, 2014, 361(1): 1-8

[13]

ModaneseC, ArnbergL, SabatinoM D. Analysis of impurities with inhomogeneous distribution in multicrystalline solar cell silicon by glow discharge mass spectrometry [J]. Materials Science and Engineering B, 2014, 180(2): 27-32

[14]

SabatinoM D. Detection limits for glow discharge mass spectrometry (GDMS) analyses of impurities in solar cell silicon [J]. Measurement, 2014, 50(1): 135-140

[15]

QianR, ZhuoS, WangZ, RobinsonP K. Direct current glow discharge mass spectrometric analysis of non-conducting materials using a surface coating method [J]. Journal of Analytical Atomic Spectrometry, 2013, 28(7): 1061-1067

[16]

ZhangP, FuL, MaJ, TangYou. Determination of impurity elements in MnZn ferrites by inductively coupled plasma mass spectrometry [J]. Journal of Central South University, 2015, 22(1): 37-42

[17]

LangeB, MatschatR, KipphardtH. Enhancement of intensities in glow discharge mass spectrometry by using mixtures of argon and helium as plasma gases [J]. Analytical and Bioanalytical Chemistry, 2007, 389(78): 2287-2296

[18]

YuX, LiX, WangHai. Interference correction in analysis of stainless steel and multi-element determination by glow discharge quadrupole mass spectrometry [J]. International Journal of Mass Spectrometry, 2007, 262(12): 25-32

[19]

NieX, LiangY, TangY, XieHua. Trace amounts of impurities in electrolytic manganese metal by sector field inductively coupled plasma mass spectrometry [J]. Journal of Central South University, 2013, 20(12): 3385-3390

[20]

AhmadiH, BoliniusD J, JahnkeA, MacleodM. Mass transfer of hydrophobic organic chemicals between silicone sheets and through plant leaves and low-density polyethylene [J]. Chemosphere, 2016, 164: 683-690

AI Summary AI Mindmap
PDF

150

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/