New reclosing scheme of distribution system for utilization of BESS using wavelet transform

Keon-Woo Park , Chul-Hwan Kim , Sang-Hyuk Lee , Sang-Bong Rhee

Journal of Central South University ›› 2018, Vol. 25 ›› Issue (1) : 78 -83.

PDF
Journal of Central South University ›› 2018, Vol. 25 ›› Issue (1) : 78 -83. DOI: 10.1007/s11771-018-3718-7
Article

New reclosing scheme of distribution system for utilization of BESS using wavelet transform

Author information +
History +
PDF

Abstract

This paper proposed the reclosing method in distribution system with battery energy storage system (BESS) using wavelet transform (WT). The proposed method performs the WT of load current and then calculates the absolute value of slope of detail coefficient. The mother wavelet used is db4 of level 6. The fault clearing is detected using the rapid increase of this value. After the detection of fault clearing, the reclosing is performed. To verify the proposed method, various simulations according to the fault clearing times, fault resistances, and fault lengths are performed using EMTP. The simulation results show that fault clearing can be detected using proposed absolute value of slope of detail coefficient and hence the reclosing can be performed successfully.

Keywords

distribution system / electro-magnetic transient program / reclosing / battery energy storage system / wavelet transform

Cite this article

Download citation ▾
Keon-Woo Park, Chul-Hwan Kim, Sang-Hyuk Lee, Sang-Bong Rhee. New reclosing scheme of distribution system for utilization of BESS using wavelet transform. Journal of Central South University, 2018, 25(1): 78-83 DOI:10.1007/s11771-018-3718-7

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

HeoJ Y, OhY S, SeoH C, KimC H. An adaptive autoreclosure scheme with reference to transient stability for transmission lines [J]. Journal of Electrical Engineering&Technology, 2015, 10(3): 795-803

[2]

RadojevićZ M, ShinJ-RIN. New digital algorithm for adaptive reclosing based on the calculation of the faulted phase voltage total harmonic distortion factor [J]. IEEE Trans. Power Delivery, 2007, 22: 37-41

[3]

GolshanM E, GolbonN. Detecting secondary arc extinction time by analyzing low frequency components of faulted phase voltage or sound phase current waveforms [J]. Electrical Engineering, 2006, 88: 141-148

[4]

TerzijaV V, RadojevićZ M. Numerical algorithm for adaptive autoreclosure and protection of medium- voltage overhead lines [J]. IEEE Transactions on Power Delivery, 2004, 19(2): 554-559

[5]

AhnS-P, KimC-H, RajK A, AllanT JOHNS. An alternative approach to adaptive single pole auto-reclosing in high voltage transmission systems based on variable dead time control [J]. IEEE Trans On Power Delivery, 2001, 16(4): 676-686

[6]

MohammadA H S, MohdH ALI. Combined operation of SVC and optimal reclosing of circuit breakers for power system transient stability enhancement [J]. Electric Power Systems Research, 2014, 106: 241-248

[7]

LuoX-h, HuangC, JiangY-qun. Improved digital algorithm for adaptive reclosing for transmission lines with shunt reactors [J]. IET Generation, Transmission & Distribution, 2016, 10(9): 2066-2070

[8]

WangX-p, YangJ, LiuP, LiuW-q, YanJ, TangY-f, HeH-bo. Online calculation for the optimal reclosing time of transmission lines [J]. Electric Power Components and Systems, 2016, 44(17): 1904-1916

[9]

VogelsangJ, RomeisC, JaegerJ. Real-time adaption of dead time for single-phase autoreclosing [J]. IEEE Transactions on Power Delivery, 2016, 31(4): 1882-1890

[10]

OhJ-H, KimJ-Chul. Feature extraction of fault currents associated with multi-shot reclosing scheme in power distribution system [J]. International Journal of Electrical Power & Energy Systems, 2002, 24(1): 79-85

[11]

ParkJ-H, SeoH-C, KimC-H, RheeS-Bong. Development of adaptive reclosing scheme using wavelet transform of neutral line current in distribution system [J]. Electric Power Components and Systems, 2016, 44(4): 426-433

[12]

LeeJ-W, KimW-K, OhY-S, SeoH-C, JangW-H, KimY S, ParkC-W, KimC-Hwan. Algorithm for fault detection and classification using wavelet singular value decomposition for wide-area protection [J]. Journal of Electrical Engineering & Technology, 2015, 10(3): 729-739

[13]

JiangF, BoZ Q, YangQ X. The wavelet transform applied to distinguish between transient and permanent fault [C]. Int Conf Power Syst Technol, 199811161120

[14]

KimC H, AggarwalR K. Wavelet transform in power system. Part I. General introduction to the wavelet transform [J]. IEEE Power Eng J, 2000, 14(2): 81-87

[15]

VetterliM, HerleyC. Wavelets and filter banks: Theory and design [J]. IEEE Trans Signal Process, 1992, 40(9): 2207-2232

AI Summary AI Mindmap
PDF

125

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/