Thermal-hydraulic modeling and analysis of hydraulic system by pseudo-bond graph

Jun-ping Hu , Ke-jun Li

Journal of Central South University ›› 2015, Vol. 22 ›› Issue (7) : 2578 -2585.

PDF
Journal of Central South University ›› 2015, Vol. 22 ›› Issue (7) : 2578 -2585. DOI: 10.1007/s11771-015-2787-0
Article

Thermal-hydraulic modeling and analysis of hydraulic system by pseudo-bond graph

Author information +
History +
PDF

Abstract

To increase the efficiency and reliability of the thermodynamics analysis of the hydraulic system, the method based on pseudo-bond graph is introduced. According to the working mechanism of hydraulic components, they can be separated into two categories: capacitive components and resistive components. Then, the thermal-hydraulic pseudo-bond graphs of capacitive C element and resistance R element were developed, based on the conservation of mass and energy. Subsequently, the connection rule for the pseudo-bond graph elements and the method to construct the complete thermal-hydraulic system model were proposed. On the basis of heat transfer analysis of a typical hydraulic circuit containing a piston pump, the lumped parameter mathematical model of the system was given. The good agreement between the simulation results and experimental data demonstrates the validity of the modeling method.

Keywords

thermodynamics / hydraulic system / pseudo-bond graph / piston pump / modeling / temperature simulation

Cite this article

Download citation ▾
Jun-ping Hu, Ke-jun Li. Thermal-hydraulic modeling and analysis of hydraulic system by pseudo-bond graph. Journal of Central South University, 2015, 22(7): 2578-2585 DOI:10.1007/s11771-015-2787-0

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

LiY-l, XuH-j, CaoL-mou. Efficiency analysis and thermal-hydraulic modeling of aerial piston pump at whole work condition [J]. Journal of Beijing University of Aeronautics and Astronautics, 2010, 36(12): 1469-1472

[2]

LiuW-p, WangL-t, JiangZ-liang. Oil temperature analysis and determination of slippage pump discharge of closed hydraulic system [J]. Journal of Central South University (Science and Technology), 2013, 44(9): 3658-3664

[3]

SiddersJ A, TilleyD G, ChappieP J. Thermal-hydraulic performance prediction in fluid power systems [J]. Proceedings of the Institution of Mechanical Engineers, Part I: Journal of Systems and Control Engineering, 1996, 210(4): 231-242

[4]

ZhangZ, ZhouR-x, WangZ-j, JiaW-tong. Landing gear retraction system of modular modeling and thermal-hydraulic simulation [J]. Modular Machine Tool & Automatic Manufacturing Technique, 201336-38

[5]

LiC-g, JiaoZ-xia. Calculation method for thermal-hydraulic system simulation [J]. Journal of Heat Transfer, 2008, 130(8): 084503

[6]

HanM-h, CaoK-q, HuL-m, LiY-lin. Thermal model and simulation on hydraulic piston pump based on AMESim [J]. Machine Tool & Hydraulic, 2012, 40(1): 136-138

[7]

WangJ-p, QinS-c, ZhaoK-li. Thermal balance of hydraulic system of a 50 type wheel loader [J]. Journal of Jilin University (Engineering and Technology Edition), 2009, 39(3): 652-656

[8]

LiangL, TianL, QinG, ZhanfJie. Thermodynamic model and experimental study of twin tube hydraulic damper [J]. J Huazhong Univ of Sci & Tech (Natural Science Edition), 2012, 40(8): 7-11

[9]

YaoJ-j, FuW, HuS-h, HanJ-wei. Amplitude phase control for electro-hydraulic servo system based on normalized least-mean-square adaptive filtering algorithm [J]. Journal of Central South University of Technology, 2011, 18: 755-759

[10]

SamantarayA K, BouamamaB OModel-based process supervision—A bond graph approach [M], 2008LondonSpringer Verlag22-43

[11]

KarnoppD C, MargolisD L, RosenbergR CSystem dynamics: Modeling, simulation, and control of mechatronic systems [M], 2012New YorkJohn Wiley & Sons548-590

[12]

MandalM, PalS K. Pseudo-bond graph modeling of temperature distribution in a through-process steel rolling [J]. Mathematics and Computers in Simulation, 2008, 77(1): 81-95

[13]

AbbèsM, FarhatA, MamiA, Dauphin-TanguyG. Pseudo bond graph model of coupled heat and mass transfers in a plastic tunnel greenhouse [J]. Simulation Modelling Practice and Theory, 2010, 18(9): 1327-1341

[14]

LiY-l, CaoK-q, XuH-j, SuX-bing. Thermal-hydraulic modeling and simulation of hydraulic system based on Dymola [J]. Journal of System Simulation, 2010, 2(9): 2043-2047

[15]

BouamamaB O. Bond graph approach as analysis tool in thermofluid model library conception [J]. Journal of the Franklin Institute, 2003, 340(1): 1-23

[16]

ImagineS AThermal-Hydraulic Library User Manual [M], 20101-65

[17]

BorutzkyWBond graph methodology: Development and analysis of multidisciplinary dynamic system models [M], 2009LondonSpringer Verlag438-455

[18]

MedjaherK, SamantarayA K, Ould BouamamaB. Bond graph model of a vertical U-tube steam condenser coupled with a heat exchanger [J]. Simulation Modelling Practice and Theory, 2009, 17(1): 228-239

[19]

WattonJFundamentals of fluid power control [M], 2009New YorkCambridge University Press61-109

[20]

Van WylenG P, SonntagR EFundamentals of Classical Thermodynamics [M], 2008New YorkWiley90-160

[21]

KaznessisY NStatistical thermodynamics and stochastic kinetics: An introduction for engineers [M], 2011New YorkCambridge University Press1-79

AI Summary AI Mindmap
PDF

93

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/