Performance enhancement of filled-type solar collector with U-tube

Ruo-bing Liang , Ji-li Zhang , Liang Zhao , Liang-dong Ma

Journal of Central South University ›› 2015, Vol. 22 ›› Issue (3) : 1124 -1131.

PDF
Journal of Central South University ›› 2015, Vol. 22 ›› Issue (3) : 1124 -1131. DOI: 10.1007/s11771-015-2624-5
Article

Performance enhancement of filled-type solar collector with U-tube

Author information +
History +
PDF

Abstract

In order to increase the efficiency of solar collector, a methodology is proposed based on the analysis of its influencing factors, such as thermal conductivity of filled layer, structure forms of filled layer and heat loss coefficient. The results of analysis show that the heat transfer between pipes in evacuated tube is one of the most important factors, which can lead to the decrease of the outlet temperature of working fluid. In order to eliminate the negative influence of the heat transfer between pipes, the hollow filled-type evacuated tube with U-tube (HUFET) was developed, and the heat transfer characteristics of HUFET were analyzed by theoretical and experimental studies. The results show that the thermal resistances decrease with the increase of the thermal conductivity of filled layer. When the thermal conductivity is over 10 W/(m·K), the change of thermal resistances is very little. Furthermore, the larger the thermal conductivity of filled layer, the less the rate of the energy transfer between the two pipes to the total energy transfer, which is between the absorber tube and the working fluid. There is a little difference between the efficiencies of HUFET and UFET, with the efficiency of HUFET 2.4% higher than that of UFET. Meanwhile, the validation of the model developed was confirmed by the experiment.

Keywords

performance enhancement / filled-type / evacuated tube / U-tube

Cite this article

Download citation ▾
Ruo-bing Liang, Ji-li Zhang, Liang Zhao, Liang-dong Ma. Performance enhancement of filled-type solar collector with U-tube. Journal of Central South University, 2015, 22(3): 1124-1131 DOI:10.1007/s11771-015-2624-5

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

QuM, YinH X, ArcherD H. A solar thermal cooling and heating system for a building: Experimental and model based performance analysis and design [J]. Solar Energy, 2010, 84(2): 166-182

[2]

TanzeenS, GrahamL M, GaryR. Thermal performance of a novel rooftop solar micro-concentrating collector [J]. Solar Energy, 2012, 86(7): 1992-2000

[3]

Al-aliliA, HwangY, RadermacherR, KuboI. A high maximal efficiency solar air conditioner using concentrating photovoltaic/thermal collectors [J]. Appled Energy, 2012, 93: 138-147

[4]

MorrisonG L, BudihardjoI, BehniaM. Measurement and simulation of flow rate in a water-in-glass evacuated tube solar water heater [J]. Solar Energy, 2005, 78(2): 257-267

[5]

BudihardjoI, MorrisonG L. Performance of water-in-glass evacuated tube solar water heaters [J]. Solar Energy, 2009, 83(1): 49-56

[6]

ShahL J, FurboS. Theoretical flow investigations of an all glass evacuated tubular collector [J]. Solar Energy, 2007, 81(6): 822-828

[7]

DovicD, AndrassyM. Numerically assisted analysis of flat and corrugated plate solar collectors thermal performances [J]. Solar Energy, 2012, 86(9): 2416-2431

[8]

RiffatS B, ZhaoX, DoherrtyP S. Developing of a theoretical model to investigate thermal performance of a thin membrane heat pipe solar collector [J]. Applied Thermal Engineering, 2005, 25(5/6): 899-915

[9]

RiffatS B, ZhaoX. A novel hybrid heat pipe solar collector/CHP system-Part 1: System design and construction [J]. Renewable Energy, 2004, 29(15): 2217-2233

[10]

DiazG. Performance analysis and design optimization of a mini-channel evacuated-tube solar collector [M]. Boston, Massachusetts, USA: Proceedings of ASME IMECE, 2008

[11]

KimY, SeoT. Thermal performances comparisons of the glass evacuated tube solar collectors with shapes of absorber tube [J]. Renewable Energy, 2007, 32(5): 772-795

[12]

WanF-c, JiangL-l, FuW-biao. Design optimization of heat pipe flat plate solar collectors [J]. Cry & Supercond, 2009, 362: 55-57

[13]

LiangR B, MaL D, ZhangJ L, ZhaoD. Theoretical and experimental investigation of the filled-type evacuated tube solar collector with U tube [J]. Solar Energy, 2011, 85(11): 1735-1744

[14]

LiangR B, MaL D, ZhangJ L, ZhaoL. Performance analysis of a new-design filled-type solar collector with double U-tubes [J]. Energy and Buildings, 2013, 57: 220-226

[15]

HellströmGGround heat storage, thermal analysis of duct storage systems [D], 1991, Sweden, Department of Mathematical Physics, University of Lund

[16]

DuffieJ A, BechmanW ASolar engineering of thermal processes [M], 1980, New York, USA, John Wiley & Sons

AI Summary AI Mindmap
PDF

99

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/