Determination of interference fit value on entire roller embedded shapemeter roll
Hai-miao Wu , Hong-min Liu , Bing-qiang Yu , Li-po Yang
Journal of Central South University ›› 2014, Vol. 21 ›› Issue (12) : 4503 -4508.
Determination of interference fit value on entire roller embedded shapemeter roll
For entire roller embedded shapemeter roll, the relationship between the value of interference fit and the sensor pre-pressure, and the pressure transfer performance of shapemeter roll were analyzed by elasticity theory during the cold reversible rolling process. Considering the influence of strip temperature on the interference fit, the distributions of contact pressure of the framework’s top surface and the sensor pre-pressure on different values of interference fit were analyzed by the finite element technology. The results show that the contact pressure of the framework’s top surface and the sensor pre-pressure increase with the increase of the value of interference fit. When the value of interference fit is between 0.05 mm and 0.09 mm, roll body’s inner hole surface, the framework and pressure magnetic sensitive component don’t separate from each other, and the sensor works in the linear segment of characteristic curve, so the normal operation of shapemeter roll is guaranteed.
reversible rolling / shapemeter roll / value of interference fit / contact pressure / finite element