Structural behaviors of steel roof truss exposed to pool fire

Chang-kun Chen , Wei Zhang

Journal of Central South University ›› 2012, Vol. 19 ›› Issue (7) : 2054 -2060.

PDF
Journal of Central South University ›› 2012, Vol. 19 ›› Issue (7) : 2054 -2060. DOI: 10.1007/s11771-012-1244-6
Article

Structural behaviors of steel roof truss exposed to pool fire

Author information +
History +
PDF

Abstract

Experimental research was conducted to study the structural behaviors of a steel roof truss model without fire-proof coating under pool fire conditions. The data of temperature distribution and displacements of typical members were obtained. It is found that the temperature distribution of environment inside the structure, which is found to be in accordance with the multi-zone model with height, has a decisive effect on the temperature evolution of steel members. Besides, it can also be observed that due to the restriction and coordination among the truss members in the localized fire, the maximum relative deflection, which occurs at the mid-span of the top chord, is relatively slight and has not exceeded 1 mm under experimental conditions. On the other hand, the column experiences a notable thermal expansion during the test. Then, a finite element model is presented and validated by the test results.

Keywords

steel roof truss / fire test / multi-zone model / finite element analysis

Cite this article

Download citation ▾
Chang-kun Chen, Wei Zhang. Structural behaviors of steel roof truss exposed to pool fire. Journal of Central South University, 2012, 19(7): 2054-2060 DOI:10.1007/s11771-012-1244-6

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

WangX.-li.Analysis and concept design of large span spatial structure [M], 2008BeijingChina Machine Press223-236

[2]

NunoS., DinarC.. Elastic buckling and second-order behavior of pitched-roof steel frames [J]. Journal of Constructional Steel Research, 2007, 63(6): 804-818

[3]

AttilaF., MillósI.. Experimentally analyzed stability and ductility behavior of a space-truss roof system [J]. Thin-Walled Structures, 2004, 42(2): 309-320

[4]

CaglayanO., YukselE.. Experimental and finite element investigations on the collapse of a Mero space truss roof structure-A case study [J]. Engineering Failure Analysis, 2008, 15(5): 458-470

[5]

SakaM. P.. Optimum design of pitched roof steel frames with haunched rafters by genetic algorithm [J]. Computers and Structures, 2003, 81(18/19): 1967-1978

[6]

AsgarianB., MoradiS.. Seismic response of steel braced frames with shape memory alloy braces [J]. Journal of Constructional Steel Research, 2011, 67(1): 65-74

[7]

WangY. C.Steel and composite structures, behavior and design for fire safety [M], 2002LondonSpon Press106-113

[8]

WangY. C.. An analysis of the global structural behavior of the Cardington steel-framed building during the two BRE fire tests [J]. Engineering Structures, 2000, 22(5): 401-412

[9]

UsmaniA. S., ChungY. C., ToreroJ. L.. How did the WTC towers collapse: A new theory [J]. Fire Safety Journal, 2003, 38(6): 501-533

[10]

JinM., ZhaoJ.-c., LiuM.-l., ChangJing.. Parametric analysis of mechanical behavior of steel planar tubular truss under fire [J]. Journal of Constructional Steel Research, 2011, 67(1): 75-83

[11]

LiuM.-l., ZhaoJ.-c., JinMeng.. An experimental study of the mechanical behavior of steel planar tubular trusses in a fire [J]. Journal of Constructional Steel Research, 2010, 66(4): 504-511

[12]

ZhaoJ.-c., ShenZ.-yan.. Experimental studies of the behavior of unprotected steel frames in fire [J]. Journal of Constructional Steel Research, 1999, 50(2): 137-150

[13]

ChenC.-k., ZhangWei.. Experimental study of the mechanical behavior of steel staggered truss system under pool fire conditions [J]. Thin-Walled Structures, 2011, 49(11): 1442-1451

[14]

ChenC.-k., ZhangD., ZhangW., ShenB.-yin.. Experimental behaviors of steel staggered-truss system exposed to fire under lateral force [J]. International Journal of Steel Structures, 2012, 12(1): 59-70

[15]

KEISHI S, KAZUNORI H, TAKEYOSHI T. A multi-layer zone model for predicting fire behavior in a single room [C]// Proceedings of the Seventh International Symposium. Gaithersburg: Fire Safety Science, 2002: 851–862.

[16]

YangX. L., YinJ. H.. Slope stability analysis with nonlinear failure criterion [J]. Journal of Engineering Mechanics, 2004, 130(3): 267-273

[17]

LeeM. M. K., Llewelyn-ParryA.. Strength of ring stiffened tubular T-joints in offshore structures: A numerical parametric study [J]. Journal of Constructional Steel Research, 1999, 51(3): 239-264

[18]

Eurocode 3: EN1993-1-2: Design of steel structures-Part 1–2: General rules-Structural fire design [S]. Brussels (Belgium): Commission of European Communities, 2005.

[19]

LiG.-q., HanL.-h., LouG.-b., JiangS.-chao.Fire resistant design of steel structure and steel-concrete composite structure [J], 2006BeijingChina Architecture and Building Press89-91