Stress-strain behavior of plastic concrete using monotonic triaxial compression tests
Y. Pashang Pisheh , S. M. Mir Mohammad Hosseini
Journal of Central South University ›› 2012, Vol. 19 ›› Issue (4) : 1125 -1131.
Stress-strain behavior of plastic concrete using monotonic triaxial compression tests
The mechanical behavior of plastic concrete used in the cut-off walls of earth dams has been studied. Triaxial compression tests on the specimens in various ages and mix designs under different confining pressures have been done and the stress-strain behavior of such materials and their strength parameter changes have been experimentally investigated. It has been observed that increasing the confining pressures applied on the specimens causes the material behavior to be alike the more ductile materials and the compressive strength increases considerably as well. Moreover, a parametric study has been carried out to investigate the influence of essential parameters on the shear strength parameters of these materials. According to the research, increasing the coarse to fine aggregates ratio leads to the increase of compressive strength of the specimens as well as the increase of the cohesion and internal friction angle of the materials. Furthermore, the bentonite content decrease and the cement factor increase result in an increase of the cohesion parameter of plastic concretes and decrease of the internal friction angle of such materials.
plastic concrete / stress-strain behavior / triaxial compression test / strength / elastic modulus
| [1] |
|
| [2] |
|
| [3] |
|
| [4] |
|
| [5] |
|
| [6] |
|
| [7] |
|
| [8] |
ZOORASNA Z, HAMIDI A, GHANBARI A. Stress-strain analysis of different concrete cutoff wall connection systems, case study: Karkheh storage dam [C]// Proceeding of the Sixth International Conference on Case Histories in Geotechnical Engineering. Arlington, USA, 2008: 407–413. |
| [9] |
|
| [10] |
ICOLD. Filling materials for watertight cut off walls [R]. International Committee of Large Dams. Paris: Bulletin No. 51, 1985. |
| [11] |
REMR. Design procedure for plastic concrete cut-off walls [R]. Technical note GT-SR-1.3. 1992. |
| [12] |
ASTM. Test method for unconfined compressive strength of cohesive soils [M]. Annual book of ASTM standards. American Society of Testing and Materials. ASTM D2166, Philadelphia, 1989. |
| [13] |
ASTM. Test method for unconsolidated undrained compressive strength of cohesive soils in triaxial compression [M]. Annual book of ASTM standards. American Society of Testing and Materials. ASTM D2850, Philadelphia, 1989. |
| [14] |
|
| [15] |
|
| [16] |
|
| [17] |
|
| [18] |
|
| [19] |
|
| [20] |
|
| [21] |
|
/
| 〈 |
|
〉 |