Non-invasive glucose measuring apparatus based on conservation of energy method

Zhen-cheng Chen , Xing-liang Jin , Jian-ming Zhu , Di-ya Wang , Ting-ting Zhang

Journal of Central South University ›› 2009, Vol. 16 ›› Issue (6) : 982 -986.

PDF
Journal of Central South University ›› 2009, Vol. 16 ›› Issue (6) : 982 -986. DOI: 10.1007/s11771-009-0163-7
Article

Non-invasive glucose measuring apparatus based on conservation of energy method

Author information +
History +
PDF

Abstract

A new non-invasive blood glucose measuring apparatus (NBGMA) made up of MSP430F149 SCM (single chip micyoco) was developed, which can measure blood glucose level (BGL) frequently, conveniently and painlessly. The hardware and software of this apparatus were designed, and detecting algorithms based on conservation of energy method (COEM) were presented. According to the law of conservation of energy that the energy derived by human body equals energy consumed by metabolism, and the relationship between convection, evaporation, radiation and the BGL was established. The sensor module was designed. 20 healthy volunteers were involved in the clinical experiment. The BGL measured by an automatic biochemical analyzer (ABA) was set as the reference. Regression analysis was performed to compare the conservation of energy method with the biochemical method, using the 20 data points with blood glucose concentrations ranging from 680 to 1 100 mg/L. Reproducibility was measured for healthy fasting volunteers. The results show that the means of BGL detected by NBGMA and ANA are very close to each other, and the difference of standard deviation (SD) is 24.7 mg/L. The correlative coefficient is 0.807. The coefficient of variation (CV) is 4% at 921.6 mg/L. The resultant regression is evaluated by the Clarke error grid analysis (EGA) and all data points are included in the clinically acceptable regions (region A: 100%, region B: 0%). Accordingly, it is feasible to measure BGL with COEM.

Keywords

single chip / non-invasive measurement / blood glucose / conservation of energy method

Cite this article

Download citation ▾
Zhen-cheng Chen, Xing-liang Jin, Jian-ming Zhu, Di-ya Wang, Ting-ting Zhang. Non-invasive glucose measuring apparatus based on conservation of energy method. Journal of Central South University, 2009, 16(6): 982-986 DOI:10.1007/s11771-009-0163-7

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

YangG.-huang.Pathology [M], 2004, Beijing, People’s Medical Publishing House

[2]

ChenZ.-c., JinX.-l., XuX.-w., ZhuJ.-m., WangD.-ya.. A primary research of non-invasive glucose measuring apparatus[J]. Chinese Journal of Sensors and Actuators, 2008, 21(7): 1119-1123

[3]

YamaguchiM., KawabataY., KambeS., WardellK., MystromF. H., NaitohK., YoshidaH.. Non-invasive monitoring of gingival crevicular fluid for estimation of blood glucose level[J]. Medical and Biological Engineering, and Computing, 2004, 43(3): 322-327

[4]

SunF., KongD.-y., MeiTao.. Technology and prospects of noninvasive blood glucose measurement[J]. Journal of Biomedical Engineering, 2005, 22(1): 171-174

[5]

WeijmanI., RosW. J., RuttenG. E., SchaufeliW. B., SchabracqM. J., WinnubstJ. A.. Frequency and perceived burden of diabetes self-management activities in employees with insulin-treated diabetes: Relationships with health outcomes[J]. Diabetes Res Clin Pract, 2005, 68(1): 56-64

[6]

ChenZ.-c., FangC., WangH.-yan.. A novel disposable amperometric UA strip[J]. Sensors and Actuators, B: Chemical, 2008, 129(2): 710-715

[7]

YuS. Y., ChiuJ. H., YangS. D., HsuY. C., LuiW. Y., WuC. W.. Biological effect of far-infrared therapy on increasing skin microcirculation in rats[J]. Photodermatology, Photoimmunology & Photomedicine, 2006, 22(2): 78-86

[8]

WeissR., YegorchikovY., ShustermanA., RazI.. Noninvasive continuous glucose monitoring using photoacoustic technology-results from the first 62 subjects[J]. Diabetes Technol Ther, 2007, 9(1): 68-74

[9]

ChenZ.-c., WangH.-y., HeJ.-s., DengZ.-sheng.. Development and clinical application of biosensor for detecting uric acid in whole-blood[J]. Chinese Journal of Analytical Chemistry, 2007, 35(4): 615-618

[10]

SiegA., GuyR. H., Gado-CharroM. B.. Noninvasive and minimally invasive methods for transdermal glucose monitoring[J]. Diabetes Technol Ther, 2005, 7(1): 174-197

[11]

YamaguchiM., KambeS., YamazakiK., KobayashiM.. Error grid analysis of noninvasive glucose monitoring via gingival crevicular fluid[J]. IEEE Trans Biomed Eng, 2005, 52(10): 1796-1798

[12]

ChenZ.-c., GongQ., WangD.-y., XuX.-w., ZhuJ.-m., JinX.-liang.. Design of non-invasive blood sugar measuring sensor based on energy metabolic conservation[J]. Chinese Journal of Sensors and Actuators, 2008, 21(5): 724-728

[13]

KuwaK.. Noninvasive blood glucose monitoring: New technology using metabolic heat conformation method[J]. Rinsho Byori, 2006, 54(5): 519-525

[14]

CaduffA., HirtE., FeldmanY., HeinemannL.. First human experiments with a novel non-invasive, non-optical continuous glucose monitoring system[J]. Biosens Bioelectron, 2003, 19(3): 209-217

[15]

ChenW.-l., CuiH.-x., LiuR., XuK.-x., ChenM.-sen.. Experimental research on OGTT for non-invasive blood glucose detection through near-infrared spectroscopy ranging from 1 100 nm to 1 700 nm[J]. Journal of Biomedical Engineering, 2004, 21(5): 824-827

[16]

CHO O K, KIM Y O. Blood sugar level measuring apparatus: US, 2004/0225209[P]. 2004-11-11.

AI Summary AI Mindmap
PDF

96

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/