Bonding stress—slip constitutive behavior between bars and grout concrete

Yi Zheng , Ming Liu , Jing-hai Zhou , Bing Wang

Journal of Central South University ›› 2009, Vol. 16 ›› Issue (5) : 841 -844.

PDF
Journal of Central South University ›› 2009, Vol. 16 ›› Issue (5) : 841 -844. DOI: 10.1007/s11771-009-0139-7
Article

Bonding stress—slip constitutive behavior between bars and grout concrete

Author information +
History +
PDF

Abstract

To establish bonding stress—slip constitutive model between bars and grout concrete, 13 test specimens were employed to study the bonding behavior and the force transfer of bars adhered to grout concrete. The bonding stress development of bars adhered to grout concrete was analyzed. The local bonding stress—slip curve was obtained. Based on the test results, a new bonding stress—slip constitutive model between bars and grout concrete was proposed. The results show that the maximum bonding stress is not influenced by the bar bond length, but it is strengthened when the splitting strength of grout concrete is increased. The model matches the experimental results well, and the regressing coefficient equals 1.7.

Keywords

grout concrete / reinforced masonry / constitutive model / splitting strength / bonding stress / slip

Cite this article

Download citation ▾
Yi Zheng, Ming Liu, Jing-hai Zhou, Bing Wang. Bonding stress—slip constitutive behavior between bars and grout concrete. Journal of Central South University, 2009, 16(5): 841-844 DOI:10.1007/s11771-009-0139-7

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

DingD.-jun.Innovation of walls and sustainability of development [M], 2005, Beijing, China Machine Press

[2]

MoonL. F., YiT. Y., LeonT. R., KahnL. F.. Testing of a full-scale unreinforced masonry building following seismic strengthening [J]. Journal of Structural Engineering, 2007, 133(9): 1215-1226

[3]

National standard of the People’s Republic of China.Code for design of masonry structure (GB50003 — 2001) [S], 2002, Beijing, Chinese Construction Industry Press: 66-87

[4]

VoonK. C., InghamJ. M.. Design expression for the in-plane shear strength of reinforced concrete masonry [J]. Journal of Structural Engineering, 2007, 133(5): 706-713

[5]

JamesS., JeffW., MichaelI.. Failure mechanisms of polymer-reinforced concrete masonry walls subjected to blast [J]. Journal of Structural Engineering, 2005, 131(8): 1194-1205

[6]

ZhangX. D., SinghS., BullD. K.. Out-of plane performance of reinforced masonry walls with openings [J]. Journal of Structural Engineering, 2001, 127(1): 51-57

[7]

MesbahA., MorelJ. C., WalkerP.. Development of a direct tensile test for compacted earth blocks reinforced with natural fibers [J]. Journal of Materials in Civil Engineering, 2004, 16(1): 95-98

[8]

GavinD. W., MervynJ. K., JasonM. I.. Shake table testing of post-tensioned concrete masonry walls with openings [J]. Journal of Structural Engineering, 2007, 133(11): 1551-1559

[9]

LiuM., HuangC.-k., SunH.-feng.. Tests and research on the bond behavior of reinforcement and grout concrete [J]. Journal of Shenyang Jianzhu University: Natural Science, 2004, 20(4): 257-260

[10]

LiuM., HuangC.-k., SunH.-f., ChengY.. Study of reliability and behavior of reinforced bond in grout block masonry [J]. Journal of Dalian University of Technology, 2005, 45(6): 837-841

[11]

YeM.-x., HuangQ., WuQ.-qin.. Analysis of steel-concrete composite structure with overlap slab of Xingguang bridge [J]. Journal of Central South University of Technology, 2007, 14(1): 120-124

[12]

GuoZ.-g., SunW.-m., CaoS.-yan.. Experimental study on bond-slip behavior between FRP and concrete [J]. China Civil Engineering Journal, 2007, 40(3): 1-5

[13]

YaoJ., TengJ. G., ChenJ. F.. Experimental study on FRP-to concrete bonded joints [J]. Composites—part B: Engineering, 2005, 36(2): 99-113

[14]

LuX. Z., TengJ. G., YeL. P.. Bond-slip models for FRP sheets/plates externally bonded to concrete [J]. Engineering Structures, 2005, 27(6): 938-950

[15]

DingF.-x., YuZ.-wu.. Behavior of concrete and concrete-filled circular steel tubular stub columns at constant high temperatures [J]. Journal of Central South University of Technology, 2007, 14(6): 726-732

AI Summary AI Mindmap
PDF

109

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/