Study on the separation of Co2+ from Zn2+, Cd2+ by anion-exchange chromatography
Xin-yan Wang , Chun-shan Zhou , Yan Wang
Journal of Central South University ›› 2000, Vol. 7 ›› Issue (2) : 88 -91.
Study on the separation of Co2+ from Zn2+, Cd2+ by anion-exchange chromatography
The separation of Co2+ from Zn2+, Cd2+ by anion-exchange chromatography was discussed. The chromatographic column containing anion resin 201 × 7 which was saturated with a solution of ammonium chloride. The effects of the eluant acidity and eluant composition on the separation were investigated. The results indicate that this anion-exchange chromatography is suitable to the separation of Co2+ from Zn2+, Cd2+, and the condition of separation is simple and convenient. When the column is saturated with NH4Cl solution (2.0 mol/L, pH=4.0), the separation can be completed effectively. Zn2+ and Cd2+ can also be separated when different eluants are used and the pure solution with high concentration of Zn2+, Cd2+ respectively can be obtained easily.
anion-exchange chromatography / Zn2+ / Cd2+ / Co2+ / separation
| [1] |
XIAO Jine, ZHU Hui-ren. The quality control of the production of cobalt oxide[J]. Non-ferrous Metal Smelting(in Chinese), 1994(2): 26–29 |
| [2] |
|
| [3] |
The research group of extraction of cobalt oxide from cobalt-contained residue. Study of extraction of cobalt oxide from Jinchuan cobalt-contained residue[J]. Non-ferrous Metal Smelting(in Chinese), 1981 (3): 1–6 |
| [4] |
|
| [5] |
|
| [6] |
|
| [7] |
|
/
| 〈 |
|
〉 |