Colour stabilities of three types of orthodontic clear aligners exposed to staining agents

Chen-Lu Liu , Wen-Tian Sun , Wen Liao , Wen-Xin Lu , Qi-Wen Li , Yunho Jeong , Jun Liu , Zhi-He Zhao

International Journal of Oral Science ›› 2016, Vol. 8 ›› Issue (4) : 246 -253.

PDF
International Journal of Oral Science ›› 2016, Vol. 8 ›› Issue (4) : 246 -253. DOI: 10.1038/ijos.2016.25
Article

Colour stabilities of three types of orthodontic clear aligners exposed to staining agents

Author information +
History +
PDF

Abstract

Clear orthodontic braces can still be improved to avoid coloration changes resulting from coffee drinking. Clear aligners are an alternative to traditional teeth braces, often chosen because they are more cosmetically pleasing. Patients are advised to remove them while eating and drinking by drinking, but many do not comply. Zhi-He Zhao, Jun Liu and colleagues from Sichuan University in China tested clear aligners made of three different materials from three companies (Invisalign®, Angelalign®, and Smartee™) for coloration changes after immersion in coffee, black tea, red wine and water. The three types of devices showed color stability after 12 hours of immersion, except for the Invisalign®aligners immersed in coffee. These were more prone to pigmentation and had a rougher surface after seven days of immersion in coffee than the other aligners.

Keywords

aesthetics / clear aligner / clear aligner material / colour stability / orthodontic appliance

Cite this article

Download citation ▾
Chen-Lu Liu, Wen-Tian Sun, Wen Liao, Wen-Xin Lu, Qi-Wen Li, Yunho Jeong, Jun Liu, Zhi-He Zhao. Colour stabilities of three types of orthodontic clear aligners exposed to staining agents. International Journal of Oral Science, 2016, 8(4): 246-253 DOI:10.1038/ijos.2016.25

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Meade MJ, Millett DT, Cronin M. Social perceptions of orthodontic retainer wear. Eur J Orthod, 2014, 36(6): 649-656.

[2]

Cooper-Kazaz R, Ivgi I, Canetti L. The impact of personality on adult patients' adjustability to orthodontic appliances. Angle Orthod, 2013, 83(1): 76-82.

[3]

Maspero C, Farronato D, Giannini L. Orthodontic treatment in elderly patients. Prog Orthod, 2010, 11(1): 62-75.

[4]

Ghafari JG. Centennial inventory: the changing face of orthodontics. Am J Orthod Dentofacial Orthop, 2015, 148(5): 732-739.

[5]

Malik OH, McMullin A, Waring DT. Invisible orthodontics part 1: invisalign. Dent Update, 2013, 40(3): 213-215.

[6]

Rosvall MD, Fields HW, Ziuchkovski J. Attractiveness, acceptability, and value of orthodontic appliances. Am J Orthod Dentofacial Orthop, 2009, 135(3): 276.e1-276.e12.

[7]

Shalish M, Cooper-Kazaz R, Ivgi I. Adult patients' adjustability to orthodontic appliances. Part I: a comparison between Labial, Lingual, and Invisalign™. Eur J Orthod, 2012, 34(6): 724-730.

[8]

Martorelli M, Gerbino S, Giudice M. A comparison between customized clear and removable orthodontic appliances manufactured using RP and CNC techniques. Dent Mater, 2013, 29(2): e1-e10.

[9]

Pithon MM. A modified thermoplastic retainer. Prog Orthod, 2012, 13(2): 195-199.

[10]

Ercoli F, Tepedino M, Parziale V. A comparative study of two different clear aligner systems. Prog Orthod, 2014, 15(1): 31.

[11]

Kravitz ND, Kusnoto B, BeGole E. How well does Invisalign work? A prospective clinical study evaluating the efficacy of tooth movement with Invisalign. Am J Orthod Dentofacial Orthop, 2009, 135(1): 27-35.

[12]

Hahn W, Engelke B, Jung K. Initial forces and moments delivered by removable thermoplastic appliances during rotation of an upper central incisor. Angle Orthod, 2010, 80(2): 239-246.

[13]

Fujiwara K, Fukuhara T, Niimi K. Mechanical evaluation of newly developed mouthpiece using polyethylene terephthalate glycol for transoral robotic surgery. J Robot Surg, 2015, 9(4): 347-354.

[14]

Clements KM, Bollen AM, Huang G. Activation time and material stiffness of sequential removable orthodontic appliances. Part 2: dental improvements. Am J Orthod Dentofacial Orthop, 2003, 124(5): 502-508.

[15]

Ahn HW, Ha HR, Lim HN. Effects of aging procedures on the molecular, biochemical, morphological, and mechanical properties of vacuum-formed retainers. J Mech Behav Biomed Mater, 2015, 51: 356-366.

[16]

Drake CT, McGorray SP, Dolce C. Orthodontic tooth movement with clear aligners. ISRN Dent, 2012, 2012: 657973.

[17]

Zhang N, Bai Y, Ding X. Preparation and characterization of thermoplastic materials for invisible orthodontics. Dent Mater J, 2011, 30(6): 954-959.

[18]

Ziuchkovski JP, Fields HW, Johnston WM. Assessment of perceived orthodontic appliance attractiveness. Am J Orthod Dentofacial Orthop, 2008, 133(4 Suppl): S68-S78.

[19]

Inami T, Tanimoto Y, Minami N. Color stability of laboratory glass-fiber-reinforced plastics for esthetic orthodontic wires. Korean J Orthod, 2015, 45(3): 130-135.

[20]

Dietschi D, Campanile G, Holz J. Comparison of the color stability of ten new-generation composites: an in vitro study. Dent Mater, 1994, 10(6): 353-362.

[21]

Ardeshna AP, Vaidyanathan TK. Colour changes of orthodontic elastomeric module materials exposed to in vitro dietary media. J Orthod, 2009, 36(3): 177-185.

[22]

Kim SH, Lee YK. Measurement of discolouration of orthodontic elastomeric modules with a digital camera. Eur J Orthod, 2009, 31(5): 556-562.

[23]

Fernandes AB, Ruellas AC, Araújo MV. Assessment of exogenous pigmentation in colourless elastic ligatures. J Orthod, 2014, 41(2): 147-151.

[24]

Tsomos G, Ludwig B, Grossen J. Objective assessment of patient compliance with removable orthodontic appliances: a cross-sectional cohort study. Angle Orthod, 2014, 84(1): 56-61.

[25]

The National Coffee Association and The Specialty Coffee Association of America. Coffee Statistics. Available at http://www.e-importz.com/coffee-statistics.php accessed on 15 July 2015.

[26]

Wriedt S, Schepke U, Wehrbein H. The discoloring effects of food on the color stability of esthetic brackets—an in-vitro study. J Orofac Orthop, 2007, 68(4): 308-320.

[27]

Gerard BT, Teske L, Eliades G. Do the mechanical and chemical properties of Invisalign appliances change after use? A retrieval analysis. Eur J Orthod, 2016, 38(1): 27-31.

[28]

Alexandropoulos A, Al Jabbari YS, Zinelis S. Chemical and mechanical characteristics of contemporary thermoplastic orthodontic materials. Aust Orthod J, 2015, 31(2): 165-170.

[29]

Premaraj T, Simet S, Beatty M. Oral epithelial cell reaction after exposure to Invisalign plastic material. Am J Orthod Dentofacial Orthop, 2014, 145(1): 64-71.

[30]

Elkholy F, Panchaphongsaphak T, Kilic F. Forces and moments delivered by PET-G aligners to an upper central incisor for labial and palatal translation. J Orofac Orthop, 2015, 76(6): 460-475.

[31]

Zafeiriadis AA, Karamouzos A, Athanasiou AE. In vitro spectrophotometric evaluation of Vivera clear thermoplastic retainer discolouration. Aust Orthod J, 2014, 30(2): 192-200.

[32]

de Oliveira CB, Maia LG, Santos-Pinto A. In vitro study of color stability of polycrystalline and monocrystalline ceramic brackets. Dental Press J Orthod, 2014, 19(4): 114-121.

[33]

Johnston WM. Color measurement in dentistry. J Dent, 2009, 37(Suppl 1): e2-e6.

[34]

Cörekçi B, Irgın C, Malkoç S. Effects of staining solutions on the discoloration of orthodontic adhesives: an in-vitro study. Am J Orthod Dentofacial Orthop, 2010, 138(6): 741-746.

[35]

Nimeroff I. Colorimetry. Natl Bureau Stand Monogr, 1968, 47: 104.

[36]

Koksal T, Dikbas I. Color stability of different denture teeth materials against various staining agents. Dent Mater J, 2008, 27(1): 139-144.

[37]

da Silva DL, Mattos CT, de Araújo MV. Color stability and fluorescence of different orthodontic esthetic archwires. Angle Orthod, 2013, 83(1): 127-132.

[38]

Oh SY, Kang MS, Knowles JC. Synthesis of bio-based thermoplastic polyurethane elastomers containing isosorbide and polycarbonate diol and their biocompatible properties. J Biomater Appl, 2015, 30(3): 327-337.

[39]

Kosobrodova E, Jones RT, Kondyurin A. Orientation and conformation of anti-CD34 antibody immobilised on untreated and plasma treated polycarbonate. Acta Biomater, 2015, 19: 128-137.

[40]

Špírková M, Pavličević J, Strachota A. Novel polycarbonate-based polyurethane elastomers: composition–property relationship. Eur Polym J, 2011, 47(5): 959-972.

[41]

Ahn HW, Kim KA, Kim SH. A new type of clear orthodontic retainer incorporating multi-layer hybrid materials. Korean J Orthod, 2015, 45(5): 268-272.

[42]

Matsui S, Umezaki E, Komazawa D et al. Evaluation of mechanical properties of esthetic brackets. J Dent Biomech 2015; 6: 1758736015574401.

[43]

Selvakumar M, Jaganathan SK, Nando GB. Synthesis and characterization of novel polycarbonate based polyurethane/polymer wrapped hydroxyapatite nanocomposites: mechanical properties, osteoconductivity and biocompatibility. J Biomed Nanotechnol, 2015, 11(2): 291-305.

[44]

Kloukos D, Taoufik E, Eliades T. Cytotoxic effects of polycarbonate-based orthodontic brackets by activation of mitochondrial apoptotic mechanisms. Dent Mater, 2013, 29(3): e35-e44.

[45]

Hamanaka I, Iwamoto M, Lassila L. Influence of water sorption on mechanical properties of injection-molded thermoplastic denture base resins. Acta Odontol Scand, 2014, 72(8): 859-865.

[46]

Lombardo Luca, Martines Elisa, Mazzanti Valentina, Arreghini Angela, Mollica Francesco, Siciliani Giuseppe. Stress relaxation properties of four orthodontic aligner materials: A 24-hour in vitro study. The Angle Orthodontist, 2017, 87(1): 11-18.

[47]

Erdemir U, Yildiz E, Eren MM. Effects of sports drinks on color stability of nanofilled and microhybrid composites after long-term immersion. J Dent, 2012, 40(Suppl 2): e55-e63.

[48]

Um CM, Ruyter IE. Staining of resin-based veneering materials with coffee and tea. Quintessence Int, 1991, 22(5): 377-386.

[49]

Fernandes AB, Ribeiro AA, Araujo MV. Influence of exogenous pigmentation on the optical properties of orthodontic elastic ligatures. J Appl Oral Sci, 2012, 20(4): 462-466.

[50]

Anon. Questions and Answers for Invisalign Treament. Available at http://www.invisalign.com.cn/faq accessed 15 July 2015.

[51]

Oliveira AS, Kaizer MR, Salgado VE. Influence of whitening and regular dentifrices on orthodontic clear ligature color stability. J Esthet Restor Dent, 2015, 27(Suppl 1): S58-S64.

[52]

Ryokawa H, Miyazaki Y, Fujishima A. The mechanical properties of dental thermoplastic materials in a simulated intraoral environment. Orthod Waves, 2006, 65(2): 64-72.

[53]

Gunter O. Polyurethane Handbook, 1994 Munich: Hanser Publishers

[54]

Schuster S, Eliades G, Zinelis S. Structural conformation and leaching from in vitro aged and retrieved Invisalign appliances. Am J Orthod Dentofacial Orthop, 2004, 126(6): 725-728.

[55]

Han JT, Zheng Y, Cho JH. Stable superhydrophobic organic-inorganic hybrid films by electrostatic self-assembly. J Phys Chem B, 2005, 109(44): 20773-20778.

[56]

Sun T, Wang G, Liu H. Control over the wettability of an aligned carbon nanotube film. J Am Chem Soc, 2003, 125(49): 14996-14997.

[57]

Tan H, Xie X, Li J. Synthesis and surface mobility of segmented polyurethanes with fluorinated side chains attached to hard blocks. Polymers, 2004, 45(5): 1495-1502.

[58]

Yang J, Gao Y, Li J. Synthesis and microphase separated structures of polydimethylsiloxane/polycarbonate-based polyurethanes. RSC Adv, 2013, 3(22): 8291-8297.

AI Summary AI Mindmap
PDF

177

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/