Abstract
Mini-implants provide stable anchorage for orthodontics, despite secondary movement over time, report dental researchers in Germany. When teeth are damaged due to misalignment, they must be rebuilt and carefully anchored to the jaw. Recently, developed mini-implants are useful for such anchorage, but they may move over time with use. Manuel Nienkemper and colleagues at Heinrich-Heine University in Düsseldorf reviewed 27 recent research studies about the displacement of mini-implants. They found that movement during the initial placement was insignificant, but secondary movement caused by dental forces over time could cause problems for the patient. The team emphasizes that mini-implants require a suitable bone site with a thin mucosal covering. They also suggest that implant failure could be avoided by inserting the implant slightly off-centre, leaving space in the opposite direction from the main orthodontic forces.
Keywords
displacement
/
migration
/
mini-implant
/
miniscrew
/
orthodontics
/
skeletal anchorage
Cite this article
Download citation ▾
Manuel Nienkemper, Jörg Handschel, Dieter Drescher.
Systematic review of mini-implant displacement under orthodontic loading.
International Journal of Oral Science, 2014, 6(1): 1-6 DOI:10.1038/ijos.2013.92
| [1] |
Fortini A, Lupoli M, Giuntoli F. Dentoskeletal effects induced by rapid molar distalization with the first class appliance. Am J Orthod Dentofacial Orthop, 2004, 125(6): 697-704.
|
| [2] |
Kokich VG, Mathews DP. Surgical and orthodontic management of impacted teeth. Dent Clin North Am, 1993, 37(2): 181-204.
|
| [3] |
Kircelli BH, Pektas ZO, Uckan S. Orthopedic protraction with skeletal anchorage in a patient with maxillary hypoplasia and hypodontia. Angle Orthod, 2006, 76(1): 156-163.
|
| [4] |
Henry PJ. Clinical experiences with dental implants. Adv Dent Res, 1999, 13: 147-152.
|
| [5] |
Cornelis MA, de Clerck HJ. Maxillary molar distalization with miniplates assessed on digital models: a prospective clinical trial. Am J Orthod Dentofacial Orthop, 2007, 132(3): 373-377.
|
| [6] |
Sugawara J, Kanzaki R, Takahashi I. Distal movement of maxillary molars in nongrowing patients with the skeletal anchorage system. Am J Orthod Dentofacial Orthop, 2006, 129(6): 723-733.
|
| [7] |
Costa A, Raffainl M, Melsen B. Miniscrews as orthodontic anchorage: a preliminary report. Int J Adult Orthodon Orthognath Surg, 1998, 13(3): 201-209.
|
| [8] |
Melsen B, Costa A. Immediate loading of implants used for orthodontic anchorage. Clin Orthod Res, 2000, 3(1): 23-28.
|
| [9] |
Kanomi R. Mini-implant for orthodontic anchorage. J Clin Orthod, 1997, 31(11): 763-767.
|
| [10] |
Yao CC, Lai EH, Chang JZ. Comparison of treatment outcomes between skeletal anchorage and extraoral anchorage in adults with maxillary dentoalveolar protrusion. Am J Orthod Dentofacial Orthop, 2008, 134(5): 615-624.
|
| [11] |
Upadhyay M, Yadav S, Patil S. Mini-implant anchorage for en-masse retraction of maxillary anterior teeth: a clinical cephalometric study. Am J Orthod Dentofacial Orthop, 2008, 134(6): 803-810.
|
| [12] |
Wilmes B, Drescher D. Vertical periodontal ligament distraction—a new method for aligning ankylosed and displaced canines. J Orofac Orthop, 2009, 70(3): 213-223.
|
| [13] |
Wilmes B, Nienkemper M, Drescher D. Application and effectiveness of a mini-implant- and tooth-borne rapid palatal expansion device: the hybrid hyrax. World J Orthod, 2010, 11(4): 323-330.
|
| [14] |
Schatzle M, Mannchen R, Zwahlen M. Survival and failure rates of orthodontic temporary anchorage devices: a systematic review. Clin Oral Implants Res, 2009, 20(12): 1351-1359.
|
| [15] |
Crismani AG, Bertl MH, Celar AG. Miniscrews in orthodontic treatment: review and analysis of published clinical trials. Am J Orthod Dentofacial Orthop, 2010, 137(1): 108-113.
|
| [16] |
Su YY . Primary stability of orthodontic mini-implants: analysis of biomechanical properties and clinical relevance. Doctoral thesis, Department of Orthodotnics, Heinrich-Heine-Universität, Düsseldorf, Germany, 2009.
|
| [17] |
Wilmes B, Drescher D. Impact of bone quality, implant type, and implantation site preparation on insertion torques of mini-implants used for orthodontic anchorage. Int J Oral Maxillofac Surg, 2011, 40(7): 697-703.
|
| [18] |
Wilmes B, Drescher D. Impact of insertion depth and predrilling diameter on primary stability of orthodontic mini-implants. Angle Orthod, 2009, 79(4): 609-614.
|
| [19] |
Kang S, Lee SJ, Ahn SJ. Bone thickness of the palate for orthodontic mini-implant anchorage in adults. Am J Orthod Dentofacial Orthop, 2007, 131(4 Suppl): S74-S81.
|
| [20] |
Kim HJ, Yun HS, Park HD. Soft-tissue and cortical-bone thickness at orthodontic implant sites. Am J Orthod Dentofacial Orthop, 2006, 130(2): 177-182.
|
| [21] |
Miyawaki S, Koyama I, Inoue M. Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage. Am J Orthod Dentofacial Orthop, 2003, 124(4): 373-378.
|
| [22] |
Wiechmann D, Meyer U, Buchter A. Success rate of mini- and micro-implants used for orthodontic anchorage: a prospective clinical study. Clin Oral Implants Res, 2007, 18(2): 263-267.
|
| [23] |
Chen CH, Chang CS, Hsieh CH. The use of microimplants in orthodontic anchorage. J Oral Maxillofac Surg, 2006, 64(8): 1209-1213.
|
| [24] |
Wilmes B, Rademacher C, Olthoff G. Parameters affecting primary stability of orthodontic mini-implants. J Orofac Orthop, 2006, 67(3): 162-174.
|
| [25] |
Wilmes B, Ottenstreuer S, Su YY. Impact of implant design on primary stability of orthodontic mini-implants. J Orofac Orthop, 2008, 69(1): 42-50.
|
| [26] |
Chen J, Esterle M, Roberts WE. Mechanical response to functional loading around the threads of retromolar endosseous implants utilized for orthodontic anchorage: coordinated histomorphometric and finite element analysis. Int J Oral Maxillofac Implants, 1999, 14(2): 282-289.
|
| [27] |
Saito S, Sugimoto N, Morohashi T. Endosseous titanium implants as anchors for mesiodistal tooth movement in the beagle dog. Am J Orthod Dentofacial Orthop, 2000, 118(6): 601-607.
|
| [28] |
Labanauskaite B, Jankauskas G, Vasiliauskas A. Implants for orthodontic anchorage. Meta-analysis. Stomatologija, 2005, 7(4): 128-132.
|
| [29] |
Garfinkle JS, Cunningham LL Jr, Beeman CS. Evaluation of orthodontic mini-implant anchorage in premolar extraction therapy in adolescents. Am J Orthod Dentofacial Orthop, 2008, 133(5): 642-653.
|
| [30] |
Liou EJ, Pai BC, Lin JC. Do miniscrews remain stationary under orthodontic forces. Am J Orthod Dentofacial Orthop, 2004, 126(1): 42-47.
|
| [31] |
Chen YH, Chang HH, Chen YJ. Root contact during insertion of miniscrews for orthodontic anchorage increases the failure rate: an animal study. Clin Oral Implants Res, 2008, 19(1): 99-106.
|
| [32] |
Kuroda S, Yamada K, Deguchi T. Root proximity is a major factor for screw failure in orthodontic anchorage. Am J Orthod Dentofacial Orthop, 2007, 131(4 Suppl): S68-S73.
|
| [33] |
Maino BG, Weiland F, Attanasi A. Root damage and repair after contact with miniscrews. J Clin Orthod, 2007, 41(12): 762-766.
|
| [34] |
Lee YK, Kim JW, Baek SH. Root and bone response to the proximity of a mini-implant under orthodontic loading. Angle Orthod, 2010, 80(3): 452-458.
|
| [35] |
Brettin BT, Grosland NM, Qian F. Bicortical vs monocortical orthodontic skeletal anchorage. Am J Orthod Dentofacial Orthop, 2008, 134(5): 625-635.
|
| [36] |
Morarend C, Qian F, Marshall SD. Effect of screw diameter on orthodontic skeletal anchorage. Am J Orthod Dentofacial Orthop, 2009, 136(2): 224-229.
|
| [37] |
Akyalcin S, McIver HP, English JD. Effects of repeated sterilization cycles on primary stability of orthodontic mini-screws. Angle Orthod, 2013, 83(4): 674-679.
|
| [38] |
Chatzigianni A, Keilig L, Duschner H. Comparative analysis of numerical and experimental data of orthodontic mini-implants. Eur J Orthod, 2011, 33(5): 468-475.
|
| [39] |
Holst AI, Karl M, Karolczak M. Quantitative assessment of orthodontic mini-implant displacement: the effect of initial force application. Quintessence Int, 2010, 41(1): 59-66.
|
| [40] |
Su YY, Wilmes B, Honscheid R. Comparison of self-tapping and self-drilling orthodontic mini-implants: an animal study of insertion torque and displacement under lateral loading. Int J Oral Maxillofac Implants, 2009, 24(3): 404-411.
|
| [41] |
Hong C, Truong P, Song HN. Mechanical stability assessment of novel orthodontic mini-implant designs: Part 2. Angle Orthod, 2011, 81(6): 1001-1009.
|
| [42] |
Hong C, Lee H, Webster R. Stability comparison between commercially available mini-implants and a novel design: Part 1. Angle Orthod, 2011, 81(4): 692-699.
|
| [43] |
Pittman JW, Navalgund A, Byun SH et al. Primary migration of a mini-implant under a functional orthodontic loading. Clin Oral Investig 2013; [ Epub ahead of print].
|
| [44] |
Jang HJ, Kwon SY, Kim SH. Effects of washer on the stress distribution of mini-implant. Angle Orthod, 2011, 82(1): 137-144.
|
| [45] |
Motoyoshi M, Yano S, Tsuruoka T. Biomechanical effect of abutment on stability of orthodontic mini-implant. A finite element analysis. Clin Oral Implants Res, 2005, 16(4): 480-485.
|
| [46] |
Singh S, Mogra S, Shetty VS. Three-dimensional finite element analysis of strength, stability, and stress distribution in orthodontic anchorage: a conical, self-drilling miniscrew implant system. Am J Orthod Dentofacial Orthop, 2011, 141(3): 327-336.
|
| [47] |
Liu TC, Chang CH, Wong TY. Finite element analysis of miniscrew implants used for orthodontic anchorage. Am J Orthod Dentofacial Orthop, 2012, 141(4): 468-476.
|
| [48] |
Chang JZ, Chen YJ, Tung YY. Effects of thread depth, taper shape, and taper length on the mechanical properties of mini-implants. Am J Orthod Dentofacial Orthop, 2012, 141(3): 279-288.
|
| [49] |
Lee J, Kim JY, Choi YJ. Effects of placement angle and direction of orthopedic force application on the stability of orthodontic miniscrews. Angle Orthod, 2013, 83(4): 667-673.
|
| [50] |
Dahlberg G . Statistical Methods for Medical and Biological Students. New YorkIntersience Publications, 1940.
|
| [51] |
Lifshitz AB, Munoz M. Evaluation of the stability of self-drilling mini-implants for maxillary anchorage under immediate loading. World J Orthod, 2010, 11(4): 352-356.
|
| [52] |
Hedayati Z, Hashemi SM, Zamiri B. Anchorage value of surgical titanium screws in orthodontic tooth movement. Int J Oral Maxillofac Surg, 2007, 36(7): 588-592.
|
| [53] |
Calderon JH, Valencia RM, Casasa AA. Biomechanical anchorage evaluation of mini-implants treated with sandblasting and acid etching in orthodontics. Implant Dent, 2011, 20(4): 273-279.
|
| [54] |
Kinzinger G, Gulden N, Yildizhan F. Anchorage efficacy of palatally-inserted miniscrews in molar distalization with a periodontally/miniscrew-anchored distal jet. J Orofac Orthop, 2008, 69(2): 110-120.
|
| [55] |
Mortensen MG, Buschang PH, Oliver DR. Stability of immediately loaded 3- and 6-mm miniscrew implants in beagle dogs—a pilot study. Am J Orthod Dentofacial Orthop, 2009, 136(2): 251-259.
|
| [56] |
Ohmae M, Saito S, Morohashi T. A clinical and histological evaluation of titanium mini-implants as anchors for orthodontic intrusion in the beagle dog. Am J Orthod Dentofacial Orthop, 2001, 119(5): 489-497.
|
| [57] |
Chang CS, Lee TM, Chang CH. The effect of microrough surface treatment on miniscrews used as orthodontic anchors. Clin Oral Implants Res, 2009, 20(10): 1178-1184.
|
| [58] |
Wang YC, Liou EJ. Comparison of the loading behavior of self-drilling and predrilled miniscrews throughout orthodontic loading. Am J Orthod Dentofacial Orthop, 2008, 133(1): 38-43.
|
| [59] |
Liu H, Lv T, Wang NN. Drift characteristics of miniscrews and molars for anchorage under orthodontic force: 3-dimensional computed tomography registration evaluation. Am J Orthod Dentofacial Orthop, 2011, 139(1): e83-e89.
|
| [60] |
Frost HM. A 2003 update of bone physiology and Wolff's Law for clinicians. Angle Orthod, 2004, 74(1): 3-15.
|
| [61] |
Frost HM. Wolff's Law and bone's structural adaptations to mechanical usage: an overview for clinicians. Angle Orthod, 1994, 64(3): 175-188.
|
| [62] |
El-Beialy AR, Abou-El-Ezz AM, Attia KH. Loss of anchorage of miniscrews: a 3-dimensional assessment. Am J Orthod Dentofacial Orthop, 2009, 136(5): 700-707.
|
| [63] |
Alves M Jr, Baratieri C, Nojima LI. Assessment of mini-implant displacement using cone beam computed tomography. Clin Oral Implants Res, 2011, 22(10): 1151-1156.
|
| [64] |
Poggio PM, Incorvati C, Velo S. “Safe zones”: a guide for miniscrew positioning in the maxillary and mandibular arch. Angle Orthod, 2006, 76(2): 191-197.
|