Effect of N2 partial pressure on comprehensive properties of antibacterial TiN/Cu nanocomposite coating

Hui Liu , Yanhui Zhao , Chuanshi Sui , Yi Li , Muhammad Ali Siddiqui , Susu Li , Tong Li , Shuyuan Zhang , Hai Wang , Tao Jin , Ling Ren , Ke Yang , Ning Zhang

International Journal of Minerals, Metallurgy, and Materials ›› 2023, Vol. 30 ›› Issue (1) : 131 -143.

PDF
International Journal of Minerals, Metallurgy, and Materials ›› 2023, Vol. 30 ›› Issue (1) : 131 -143. DOI: 10.1007/s12613-021-2387-y
Article

Effect of N2 partial pressure on comprehensive properties of antibacterial TiN/Cu nanocomposite coating

Author information +
History +
PDF

Abstract

Foreign body reactions to the wear debris and corrosion products from the implants, and bacterial infections are the main factors leading to the implant failures. In order to resolve these problems, the antibacterial TiN/Cu nanocomposite coatings with various N2 partial pressures were deposited on 304 stainless steels (SS) using an arc ion plating (AIP) system, named TiN/Cu-x (x = 0.5, 1.0, 1.5 Pa). The results of X-ray diffraction analysis, energy-dispersive X-ray spectroscopy, and scanning electron microscopy showed that the N2 partial pressures determined the Cu contents, surface defects, and crystallite sizes of TiN/Cu nanocomposite coatings, which further influenced the comprehensive abilities. And the hardness and wear resistances of TiN/Cu coatings were enhanced with increase of the crystallite sizes. Under the co-actions of surface defects, crystallite sizes, and Cu content, TiN/Cu-1.0 and TiN/Cu-1.5 coatings possessed excellent corrosion resistance. Besides, the biological tests proved that all the TiN/Cu coatings showed no cytotoxicity with strong antibacterial ability. Among them, TiN/Cu-1.5 coating significantly promoted the cell proliferation, which is expected to be a novel antibacterial, corrosion-resistant, and wear-resistant coating on the surfaces of medical implants.

Keywords

N2 partial pressure / TiN/Cu coating / wear resistance / corrosion behavior / antibacterial ability / cytocompatibility

Cite this article

Download citation ▾
Hui Liu, Yanhui Zhao, Chuanshi Sui, Yi Li, Muhammad Ali Siddiqui, Susu Li, Tong Li, Shuyuan Zhang, Hai Wang, Tao Jin, Ling Ren, Ke Yang, Ning Zhang. Effect of N2 partial pressure on comprehensive properties of antibacterial TiN/Cu nanocomposite coating. International Journal of Minerals, Metallurgy, and Materials, 2023, 30(1): 131-143 DOI:10.1007/s12613-021-2387-y

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Bijukumar DR, Salunkhe S, Zheng GX, et al. Wear particles induce a new macrophage phenotype with the potential to accelerate material corrosion within total hip replacement interfaces. Acta Biomater., 2020, 101, 586.

[2]

Arciola CR, Campoccia D, Montanaro L. Implant infections: Adhesion, biofilm formation and immune evasion. Nat. Rev. Microbiol., 2018, 16(7): 397.

[3]

Annunziata M, Oliva A, Basile MA, et al. The effects of titanium nitride-coating on the topographic and biological features of TPS implant surfaces. J. Dent., 2011, 39(11): 720.

[4]

Mengel R, Meer C, Flores-de-Jacoby L. The treatment of uncoated and titanium nitride-coated abutments with different instruments. Int. J. Oral Maxillofac. Implants, 2004, 19(2): 232

[5]

Magill SS, Edwards JR, Bamberg W, et al. Multistate point-prevalence survey of health care-associated infections. N. Engl. J. Med., 2014, 370(13): 1198.

[6]

Zimmerli W. Clinical presentation and treatment of orthopaedic implant-associated infection. J Intern. Med, 2014, 276(2): 111.

[7]

Wu CT, Zhou YH, Xu MC, et al. Copper-containing mesoporous bioactive glass scaffolds with multifunctional properties of angiogenesis capacity, osteostimulation and antibacterial activity. Biomaterials, 2013, 34(2): 422.

[8]

Campoccia D, Montanaro L, Arciola CR. A review of the clinical implications of anti-infective biomaterials and infection-resistant surfaces. Biomaterials, 2013, 34(33): 8018.

[9]

Zhang EL, Zhao XT, Hu JL, et al. Antibacterial metals and alloys for potential biomedical implants. Bioact. Mater., 2021, 6(8): 2569.

[10]

Musil J, Vlček J. Magnetron sputtering of hard nanocomposite coatings and their properties. Surf. Coat. Technol., 2001, 142–144, 557.

[11]

Lowe NM, Fraser WD, Jackson MJ. Is there a potential therapeutic value of copper and zinc for osteoporosis?. Proc. Nutr. Soc., 2002, 61(2): 181.

[12]

Gérard C, Bordeleau LJ, Barralet J, Doillon CJ. The stimulation of angiogenesis and collagen deposition by copper. Biomaterials, 2010, 31(5): 824.

[13]

Wang HF, Shu XF, Guo MQ, et al. Structural, tribological and antibacterial activities of Ti—Cu—N hard coatings prepared by plasma surface alloying technique. Surf. Coat. Technol., 2013, 235, 235.

[14]

X.Y. Luo, D.L. Ma, P.P. Jing, et al., In vitro analysis of cell compatibility of TiCuN films with different Cu contents, Surf. Coat. Technol., 408(2021), art. No. 126790.

[15]

H. Liu, X.Y. Zhang, S.J. Jin, Y.H. Zhao, L. Ren, and K. Yang, Effect of copper-doped titanium nitride coating on angiogenesis, Mater. Lett., 269(2020), art. No. 127634.

[16]

Zhao YH, Wang XQ, Xiao JQ, Yu BH, Li FQ. Ti—Cu—N hard nanocomposite films prepared by pulse biased arc ion plating. Appl. Surf. Sci., 2011, 258(1): 370.

[17]

Xie SM, Dai MJ, Lin SS, et al. Effect of bias voltage on the oxidation resistance of NiCoCrAlYTa coatings prepared by arc ion plating. Corros. Sci., 2019, 147, 330.

[18]

Zhao SS, Zhao YH, Cheng LS, et al. Effects of substrate pulse bias duty cycle on the microstructure and mechanical properties of Ti—Cu—N films deposited by magnetic field-enhanced arc ion plating. Acta Metall. Sin. Engl. Lett., 2017, 30(2): 176.

[19]

Yoozbashi MN, Yazdani S. XRD and TEM study of bainitic ferrite plate thickness in nanostructured, carbide free bainitic steels. Mater. Chem. Phys., 2015, 160, 148.

[20]

Rupp F, Gittens RA, Scheideler L, et al. A review on the wettability of dental implant surfaces I: Theoretical and experimental aspects. Acta Biomater., 2014, 10(7): 2894.

[21]

Kim HG, Ahn SH, Kim JG, Park SJ, Lee KR. Corrosion performance of diamond-like carbon (DLC)-coated Ti alloy in the simulated body fluid environment. Diam. Relat. Mater., 2005, 14(1): 35.

[22]

Liu H, Liu R, Ullah I, et al. Rough surface of copper-bearing titanium alloy with multifunctions of osteogenic ability and antibacterial activity. J. Mater. Sci. Technol., 2020, 48, 130.

[23]

Anders A. A structure zone diagram including plasma-based deposition and ion etching. Thin Solid Films, 2010, 518(15): 4087.

[24]

Zhao YH, Zhao SS, Ren L, et al. Effect of substrate pulse bias voltage on the microstructure and mechanical and wear-resistant properties of TiN/Cu nanocomposite films. Rare Met. Mater. Eng., 2018, 47(11): 3284.

[25]

Bujak J, Walkowicz J, Kusiński J. Influence of the nitrogen pressure on the structure and properties of (Ti,Al)N coatings deposited by cathodic vacuum arc PVD process. Surf. Coat. Technol., 2004, 180–181, 150.

[26]

Balashabadi P, Larijani M, Seyedi H, Jafari-Khamse E. Effect of Cu content on TiN—Cu nanocomposite film properties: Structural and hardness studies. J. Nanostructures, 2013, 3(2): 237

[27]

Hussein MA, Ankah NK, Kumar AM, et al. Mechanical, biocorrosion, and antibacterial properties of nanocrystalline TiN coating for orthopedic applications. Ceram. Int., 2020, 46(11): 18573.

[28]

B. Warcholinski, A. Gilewicz, P. Myslinski, et al., Effect of nitrogen pressure and substrate bias voltage on the properties of Al—Cr—B—N coatings deposited using cathodic arc evaporation, Tribol. Int., 154(2021), art. No. 106744.

[29]

Chokwatvikul C, Larpkiattaworn S, Surinphong S, Busabok C, Termsuksawad P. Effect of nitrogen partial pressure on characteristic and mechanical properties of hard coating TiAlN Film. J. Met. Mater. Miner., 2011, 21(1): 115

[30]

Gittens RA, Scheideler L, Rupp F, et al. A review on the wettability of dental implant surfaces II: Biological and clinical aspects. Acta Biomater., 2014, 10(7): 2907.

[31]

M.M. Bao, X.Y. Wang, L. Yang, G.W. Qin, and E.L. Zhang, Tribocorrosion behavior of Ti—Cu alloy in hank’s solution for biomedical application, J. Bio- Tribo-Corros., 4(2018), No. 2, art. No. 29.

[32]

Abdallah B, Naddaf M, A-Kharroub M. Structural, mechanical, electrical and wetting properties of ZrNx films deposited by Ar/N2 vacuum arc discharge: Effect of nitrogen partial pressure. Nucl. Instrum. Methods Phys. Res. Sect. B Beam Interact. Mater. Atoms, 2013, 298, 55.

[33]

Tjong SC, Chen H. Nanocrystalline materials and coatings. Mater. Sci. Eng. R Rep., 2004, 45(1–2): 1.

[34]

Qi ZB, Sun P, Zhu FP, et al. The inverse Hall—Petch effect in nanocrystalline ZrN coatings. Surf. Coat. Technol., 2011, 205(12): 3692.

[35]

Chou WJ, Yu GP, Huang JH. Deposition of TiN thin films on Si(100) by HCD ion plating. Surf. Coat. Technol., 2001, 140(3): 206.

[36]

Peng C, Zhao Y, Jin S, et al. Antibacterial TiCu/TiCuN multilayer films with good corrosion resistance deposited by axial magnetic field-enhanced arc ion plating. ACS Appl. Mater. Interfaces, 2019, 11(1): 125.

[37]

Souto RM, Alanyali H. Electrochemical characteristics of steel coated with TiN and TiAlN coatings. Corros. Sci., 2000, 42(12): 2201.

[38]

Chojnacka K, Mikulewicz M. Modelling of Cr and Ni ions release during orthodontic treatment: in vitro and in vivo methods. Environ. Toxicol. Pharmacol., 2014, 38(3): 932.

[39]

He CL, Zhang JL, Wang JM, et al. Effect of structural defects on corrosion initiation of TiN nanocrystalline films. Appl. Surf. Sci., 2013, 276, 667.

[40]

X.H. Bai, X.L. Shi, L.L. Xu, et al, Effects of hydrothermal treatment on physicochemical and anticorrosion properties of titanium nitride coating on pure titanium, Appl. Surf. Sci., 507(2020), art. No. 145030.

[41]

Liu CL, Lin GQ, Yang DZ, Qi M. In vitro corrosion behavior of multilayered Ti/TiN coating on biomedical AISI 316L stainless steel. Surf. Coat. Technol., 2006, 200(12–13): 4011.

[42]

Subramanian B, Jayachandran M. Electrochemical corrosion behavior of magnetron sputtered TiN coated steel in simulated bodily fluid and its hemocompatibility. Mater. Lett., 2008, 62(10–11): 1727.

[43]

Zhao JL, Xu DK, Shahzad MB, et al. Effect of surface passivation on corrosion resistance and antibacterial properties of Cu-bearing 316L stainless steel. Appl. Surf. Sci., 2016, 386, 371.

[44]

Liu R, Tang YL, Zeng LL, et al. In vitro and in vivo studies of anti-bacterial copper-bearing titanium alloy for dental application. Dent. Mater., 2018, 34(8): 1112.

[45]

Li KQ, Xia C, Qiao YQ, Liu XY. Dose-response relationships between copper and its biocompatibility/antibacterial activities. J. Trace Elem. Med. Biol., 2019, 55, 127.

AI Summary AI Mindmap
PDF

134

Accesses

0

Citation

Detail

Sections
Recommended

AI思维导图

/