A three-magnet-ring quasi-zero stiffness (QZS-TMR) isolator is designed to solve the problem of low-frequency vibration isolation in the vertical direction of precision equipment. QZS-TMR has both positive and negative stiffness structures. The positive stiffness structure consists of two mutually repelling magnetic rings and the negative stiffness structure consists of two magnetic rings nested within each other. By modulating the relative distance between positive and negative stiffness structures, the isolator can have QZS characteristics. Compared with other QZS isolators, the QZS-TMR is compact and easy to manufacture. In addition, the working load of QZS-TMR can be flexibly adjusted by varying the radial widths of the inner magnetic ring. In this paper, the static analysis of QZS-TMR is carried out to guide the design, and the low-frequency vibration isolation performance is studied. In addition, the experimental prototype of QZS-TMR is designed and manufactured. The static and vibration isolation experiments are carried out on the prototype. The results show that the initial vibration isolation frequency of the experimental prototype is about 4 Hz. The results show an excellent low-frequency vibration isolation effect, which is consistent with the theoretical research. This paper introduces a new approach to the design of the QZS isolator.

Keywords

low-frequency vibration isolation / magnet rings / quasi-zero stiffness / vibration isolator

Cite this article

Download citation ▾
Shang Wang, Lei Hou, Qingye Meng, Gengshuo Cui, Xiaodong Wang. Three-magnet-ring quasi-zero stiffness isolator for low-frequency vibration isolation. International Journal of Mechanical System Dynamics, 2024, 4(2): 153‒170 https://doi.org/10.1002/msd2.12107

References

[1]
Molyneux WG. Supports for Vibration Isolation. Her Majesty’s Stationery Office;1957.
[2]
Carrella A, Brennan MJ, Kovacic I, Waters TP. On the force transmissibility of a vibration isolator with quasi-zero-stiffness. J Sound Vib. 2009;322(4-5):707-717.
CrossRef Google scholar
[3]
Kovacic I, Brennan MJ, Lineton B. Effect of a static force on the dynamic behaviour of a harmonically excited quasi-zero stiffness system. J Sound Vib. 2009;325(4-5):870-883.
CrossRef Google scholar
[4]
Zhang YT, Cao QJ, Huang WH. Bursting oscillations in an isolation system with quasi-zero stiffness. Mech Syst Signal Process. 2021;161:107916.
CrossRef Google scholar
[5]
Hao Z, Cao Q, Wiercigroch M. Nonlinear dynamics of the quasizero-stiffness SD oscillator based upon the local and global bifurcation analyses. Nonlinear Dyn. 2017;87(2):987-1014.
CrossRef Google scholar
[6]
Ravindra B, Mallik AK. Hard Duffing-type vibration isolator with combined Coulomb and viscous damping. Int J Non Linear Mech. 1993;28(4):427-440.
CrossRef Google scholar
[7]
Meng Q, Hou L, Lin R, et al. Accurate nonlinear dynamic characteristics analysis of quasi-zero-stiffness vibration isolator via a modified incremental harmonic balance method. Nonlinear Dyn. 2024;112(1):125-150.
CrossRef Google scholar
[8]
Gatti G, Svelto C. Performance of a vibration isolator with sigmoidal force-deflection curve. J Vib Control. 2023;29(23-24):5713-5724.
CrossRef Google scholar
[9]
Zhao F, Ji J, Luo Q, Cao S, Chen L, Du W. An improved quasi-zero stiffness isolator with two pairs of oblique springs to increase isolation frequency band. Nonlinear Dyn. 2021;104(1):349-365.
CrossRef Google scholar
[10]
Gatti G. A nonlinear quasi-zero stiffness vibration isolator with quintic restoring force characteristic: a fundamental analytical insight. J Vib Control. 2023.In press.
[11]
Le TD, Ahn KK. Experimental investigation of a vibration isolation system using negative stiffness structure. Int J Mech Sci. 2013;70:99-112.
CrossRef Google scholar
[12]
Le TD, Ahn KK. A vibration isolation system in low frequency excitation region using negative stiffness structure for vehicle seat. J Sound Vib. 2011;330(26):6311-6335.
CrossRef Google scholar
[13]
Wang X, Liu H, Chen Y, Gao P. Beneficial stiffness design of a high-static-low-dynamic-stiffness vibration isolator based on static and dynamic analysis. Int J Mech Sci. 2018;142-143:235-244.
CrossRef Google scholar
[14]
Shahraeeni M, Sorokin V, Mace B, Ilanko S. Effect of damping nonlinearity on the dynamics and performance of a quasi-zerostiffness vibration isolator. J Sound Vib. 2022;526:116822.
CrossRef Google scholar
[15]
Liu C, Yu K. Superharmonic resonance of the quasi-zero-stiffness vibration isolator and its effect on the isolation performance. Nonlinear Dyn. 2020;100(1):95-117.
CrossRef Google scholar
[16]
Zhou J, Wang X, Xu D, Bishop S. Nonlinear dynamic characteristics of a quasi-zero stiffness vibration isolator with cam-roller-spring mechanisms. J Sound Vib. 2015;346:53-69.
CrossRef Google scholar
[17]
Ye K, Ji JC, Brown T. Design of a quasi-zero stiffness isolation system for supporting different loads. J Sound Vib. 2020;471:115198.
CrossRef Google scholar
[18]
Zhou J, Xu D, Bishop S. A torsion quasi-zero stiffness vibration isolator. J Sound Vib. 2015;338:121-133.
CrossRef Google scholar
[19]
Wang K, Zhou J, Xu D. Sensitivity analysis of parametric errors on the performance of a torsion quasi-zero-stiffness vibration isolator. Int J Mech Sci. 2017;134:336-346.
CrossRef Google scholar
[20]
Liu X, Huang X, Hua H. On the characteristics of a quasi-zero stiffness isolator using Euler buckled beam as negative stiffness corrector. J Sound Vib. 2013;332(14):3359-3376.
CrossRef Google scholar
[21]
Huang X, Liu X, Sun J, Zhang Z, Hua H. Effect of the system imperfections on the dynamic response of a high-static-low-dynamic stiffness vibration isolator. Nonlinear Dyn. 2014;76(2):1157-1167.
CrossRef Google scholar
[22]
Huang X, Liu X, Sun J, Zhang Z, Hua H. Vibration isolation characteristics of a nonlinear isolator using Euler buckled beam as negative stiffness corrector: a theoretical and experimental study. J Sound Vib. 2014;333(4):1132-1148.
CrossRef Google scholar
[23]
Chao TL, Xu XL, Wu ZJ, Wen SR, Li FM. Quasi-zero stiffness vibration isolators with slender Euler beams as positive stiffness elements. Mech Adv Mater Struc. 2023. In press.
[24]
Kim J, Jeon Y, Um S, Park U, Kim KS, Kim S. A novel passive quasizero stiffness isolator for ultra-precision measurement systems. Int J Precis Eng Manuf. 2019;20(9):1573-1580.
CrossRef Google scholar
[25]
Ding BX, Li X, Chen SC, Li YM. Modular quasi-zero-stiffness isolator based on compliant constant-force mechanisms for low-frequency vibration isolation. J Vib Control. 2023. In press.
[26]
Xu D, Yu Q, Zhou J, Bishop SR. Theoretical and experimental analyses of a nonlinear magnetic vibration isolator with quasi-zerostiffness characteristic. J Sound Vib. 2013;332(14):3377-3389.
CrossRef Google scholar
[27]
Wu W, Chen X, Shan Y. Analysis and experiment of a vibration isolator using a novel magnetic spring with negative stiffness. J Sound Vib. 2014;333(13):2958-2970.
CrossRef Google scholar
[28]
Jiang Y, Song C, Ma X, Wu H, Mai Z. Dynamics and stability of magnetic-air hybrid quasi-zero stiffness vibration isolation system. Int J Acoust Vib. 2023;28(1):65-75.
CrossRef Google scholar
[29]
Xie YJ, Niu F, Sun JG, Meng LS. Design and analysis of a novel quasizero stiffness isolator under variable loads. Math Probl Eng. 2022;2022:9082752.
CrossRef Google scholar
[30]
Wang MT, Su P, Liu SY, Chai K, Wang BX, Lu JF. Design and analysis of electromagnetic quasi-zero stiffness vibration isolator. J Vib Eng Technol. 2023;11:153-164.
CrossRef Google scholar
[31]
Wu JL, Zeng LZ, Han B, et al. Analysis and design of a novel arrayed magnetic spring with high negative stiffness for low-frequency vibration isolation. Int J Mech Sci. 2022;216:106980.
CrossRef Google scholar
[32]
Wang S, Xin WP, Ning YH, Li B, Hu Y. Design, experiment, and improvement of a quasi-zero-stiffness vibration isolation system. Appl Sci. 2020;10:2273.
CrossRef Google scholar
[33]
Zhou J, Wang K, Xu D, Ouyang H, Fu Y. Vibration isolation in neonatal transport by using a quasi-zero-stiffness isolator. J Vib Control. 2018;24(15):3278-3291.
CrossRef Google scholar
[34]
Wang Q, Zhou JX, Xu DL, Ouyang HJ. Design and experimental investigation of ultra-low frequency vibration isolation during neonatal transport. Mech Syst Signal Process. 2020;139:106633.
CrossRef Google scholar
[35]
Wang Q, Zhou J, Wang K, Xu D, Wen G. Design and experimental study of a compact quasi-zero-stiffness isolator using wave springs. Sci China Technol Sci. 2021;64(10):2255-2271.
CrossRef Google scholar
[36]
Yan G, Wu ZY, Wei XS, et al. Nonlinear compensation method for quasizero stiffness vibration isolation. J Sound Vib. 2022;523:116743.
CrossRef Google scholar
[37]
Yan G, Qi WH, Shi JW, et al. Bionic paw-inspired structure for vibration isolation with novel nonlinear compensation mechanism. J Sound Vib. 2022;523:116743.
[38]
Zhao TY, Yan G, Qi WH, Lu JJ, Zhang WM. Magnetically modulated tetrahedral structure for low frequency vibration isolation with adjustable load capacity. Int J Mech Sci. 2023;526:116819.
[39]
Lu JJ, Yan G, Qi WH, et al. Sliding-boundary-constrained cantilever structure for vibration isolation via nonlinear stiffness modulation. Int J Mech Sci. 2022;235:107733.
CrossRef Google scholar
[40]
Qi WH, Yan G, Lu JJ, et al. Magnetically modulated sliding structure for low frequency vibration isolation. J Sound Vib. 2022;526:116819.
CrossRef Google scholar

RIGHTS & PERMISSIONS

2024 2024 The Authors. International Journal of Mechanical System Dynamics published by John Wiley & Sons Australia, Ltd on behalf of Nanjing University of Science and Technology.
PDF

Accesses

Citations

Detail

Sections
Recommended

/