Using transient plane source sensor for determination of thermal properties of vacuum insulation panels

Pär Johanssonn , Bijan Adl-Zarrabi , Carl-Eric Hagentoft

Front. Archit. Res. ›› 2012, Vol. 1 ›› Issue (4) : 334 -340.

PDF (663KB)
Front. Archit. Res. ›› 2012, Vol. 1 ›› Issue (4) :334 -340. DOI: 10.1016/j.foar.2012.09.004
RESEARCH ARTICLE
RESEARCH ARTICLE
Using transient plane source sensor for determination of thermal properties of vacuum insulation panels
Author information +
History +
PDF (663KB)

Abstract

The energy use in buildings has to be decreased to reach the targets and regulations in the European Union. One way of reducing the energy demand is to use vacuum insulation panels (VIP) in the building envelope. To make sure the declared thermal properties of the VIP are valid for the mounted panels, in situ measurements are needed. The transient plane source (TPS) method allows fast measurement of the thermal properties of a variety of materials. However, the large anisotropy of the VIP makes it hard to interpret the temperature increase in the TPS sensor. This paper presents a comparison between an analytical solution, numerical simulations and TPS measurements of polystyrene and polystyrene with aluminum film. Polystyrene and aluminum were used instead of VIP to increase the number of setups. The numerical simulation model was validated by comparing the simulated temperature increase with an analytical solution for the polystyrene sample. The simulated temperature increase in the polystyrene sample after 40 s was 7.8% higher than the TPS measurements. For the case with polystyrene with aluminum film, the deviation was 5.7%. Losses in the wires of the TPS sensor, uncertainties regarding the material parameters and surface resistances could explain the deviations.

Keywords

Thermal properties / Transient plane source / Vacuum insulation panel / Analytical solution / Numerical simulation / Measurement

Cite this article

Download citation ▾
Pär Johanssonn, Bijan Adl-Zarrabi, Carl-Eric Hagentoft. Using transient plane source sensor for determination of thermal properties of vacuum insulation panels. Front. Archit. Res., 2012, 1(4): 334-340 DOI:10.1016/j.foar.2012.09.004

登录浏览全文

4963

注册一个新账户 忘记密码

References

RIGHTS & PERMISSIONS

This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

PDF (663KB)

1065

Accesses

0

Citation

Detail

Sections
Recommended

/