Thermal-aware relocation of servers in green data centers
Muhammad Tayyab CHAUDHRY , T. C. LING , S. A. HUSSAIN , Xin-zhu LU
Front. Inform. Technol. Electron. Eng ›› 2015, Vol. 16 ›› Issue (2) : 119 -134.
Thermal-aware relocation of servers in green data centers
Rise in inlet air temperature increases the corresponding outlet air temperature from the server. As an added effect of rise in inlet air temperature, some active servers may start exhaling intensely hot air to form a hotspot. Increase in hot air temperature and occasional hotspots are an added burden on the cooling mechanism and result in energy wastage in data centers. The increase in inlet air temperature may also result in failure of server hardware. Identifying and comparing the thermal sensitivity to inlet air temperature for various servers helps in the thermal-aware arrangement and location switching of servers to minimize the cooling energy wastage. The peak outlet temperature among the relocated servers can be lowered and even be homogenized to reduce the cooling load and chances of hotspots. Based upon mutual comparison of inlet temperature sensitivity of heterogeneous servers, this paper presents a proactive approach for thermal-aware relocation of data center servers. The experimental results show that each relocation operation has a cooling energy saving of as much as 2.1 kW·h and lowers the chances of hotspots by over 77%. Thus, the thermal-aware relocation of servers helps in the establishment of green data centers.
Servers / Green data center / Thermal-aware / Relocation
| [1] |
ABB, 2013. Efficient DC Power Supply for Data Centers. |
| [2] |
|
| [3] |
|
| [4] |
ASHRAE, 2011. 2011 Thermal Guidelines for Data Processing Environments—Expanded Data Center Classes and Usage Guidance. |
| [5] |
|
| [6] |
|
| [7] |
BBC, 2014. Energy Transfer and Storage. |
| [8] |
|
| [9] |
|
| [10] |
|
| [11] |
|
| [12] |
|
| [13] |
|
| [14] |
LD Didactic Gmbh. Converting Electrical Energy into Heat Energy—Measuring with the Joule and Wattmeter. LD DIDACTIC GmbH, Germany. |
| [15] |
|
| [16] |
|
| [17] |
|
| [18] |
Mersenne Research, Inc., 2012. Great Internet Mersenne Prime Search (GIMPS). Available from |
| [19] |
|
| [20] |
|
| [21] |
|
| [22] |
|
| [23] |
|
| [24] |
|
| [25] |
|
| [26] |
|
| [27] |
U.S. Environmental Protection Agency, 2007. Report to Congress on Server and Data Center Energy Efficiency Public Law 109-431. Available from |
| [28] |
VMware Inc., 2009. VMware vSphere Basics ESXi 5.0 vCenter Server 5.0 (in Chinese). Available from |
| [29] |
|
| [30] |
|
| [31] |
|
Higher Education Press
/
| 〈 |
|
〉 |