Novel methods by using non-vacuum insulated tubing to extend the lifetime of the tubing
Chenglong ZHOU , Guojin ZHU , Yongxiang XU , Jifei YU , Xiaoliang ZHANG , Hongzhi SHENG
Front. Energy ›› 2015, Vol. 9 ›› Issue (2) : 142 -147.
Novel methods by using non-vacuum insulated tubing to extend the lifetime of the tubing
The analysis of the failure mechanics, namely hydrogen permeation of vacuum insulated tubing (VIT), indicated that the failure of VIT could be decreased but could not be avoided. To solve this problem, some measures by using non-vacuum materials were proposed and analyzed in this paper. The results show that to fill the tubing with foam-glass beads or high pressure argon may lead to a good performance.
hydrogen permeation / vacuum insulated tubing / cyclic steam stimulation / insulation material / thermal conductivity / foam-glass
| [1] |
|
| [2] |
|
| [3] |
|
| [4] |
|
| [5] |
|
| [6] |
|
| [7] |
|
| [8] |
|
| [9] |
|
| [10] |
|
| [11] |
|
Higher Education Press and Springer-Verlag Berlin Heidelberg
/
| 〈 |
|
〉 |