An intumescent waterborne amino-resin fire-retardant coating for wood (C) was synthesized and its fire-retardant and smoke-suppressant properties were investigated. The main film-builder of C was urea-formaldehyde resin blended with polyvinyl acetate resin. The intumescent fire-retardant system of C consisted of guanylurea phosphate (GUP), ammonium polyphosphate (APP), pentaerythritol (PER) and melamine (MEL). Specimens of plywood painted, respectively, with a commercial intumescent fire-retardant coating (A), a synthesized coating (C), and the main film-builder of coating C (B), as well as an unpainted plywood (S-JHB), were analyzed by cone calorimetry (CONE). The results show a marked decrease in the heat release rate (HRR) and the total heat release (THR), an increased mass of residual char (Mass), a marked postponement in time to ignition (TTI) and a reduced carbon monoxide production rate (PCO). The smoke production rate (SPR) and total smoke production (TSP) of the plywood painted with coating C were observed with the CONE test. The overall fire-retardant and smoke-suppressant performance of the synthesized coating C was much better than that of the commercial coating A. The thermo-gravimetric analysis (TGA) results of coating C and its film-builder B indicated that the thermal degradation process of B was slowed down by the addition of the intumescent fire-retardant system; the increase in the amount of charring of coating C was considerable.
WANG Fengqiang, ZHANG Zhijun, WANG Qingwen, TANG Jiayin
. Fire-retardant and smoke-suppressant performance
of an intumescent waterborne amino-resin fire-retardant coating for
wood[J]. Frontiers of Forestry in China, 2008
, 3(4)
: 487
-492
.
DOI: 10.1007/s11461-008-0075-y
1. Charles A H (2004). Handbook of Building Materials for Fire Protection. America: McGraw-Hill, 450–460
2. Gu J W, Zhang G C, Dong S L, Zhang Q Y, Kong J (2007). Study on preparationand fire-retardant mechanism analysis of intumescent flame-retardantcoatings. Surf Coat Tech, 201(18): 7835–7841. doi:10.1016/j.surfcoat.2007.03.020
3. Hu Y, Li C, Shi H, Lu H D (1999). Application of thermal analysis in flame retardant materials. Fire Safe Sci, 8(1): 74–77 (in Chinese)
4. Jimenez M, Duquesne S, Bourbigot S (2006). Characterization of the performanceof an intumescent fire protective coating. Surf Coat Tech, 201(3–4): 979–987. doi:10.1016/j.surfcoat.2006.01.026
5. Kunze R, Schartel B, Bartholmai M, Neubert D, Schriever R (2002). TG-MSand TG-FTIR applied for an unambiguous thermal analysis of intumescentcoatings. J Therm Anal Calorimetry, 70: 897–909. doi:10.1023/A:1022272707412
6. Li B (2000). Smoke Suppression and Fire-Retardant of Poly (VinylChloride). Harbin: Northeast Forestry University Press, 85–204 (in Chinese)
7. Li G X, Liang G Z, Zhou W Y (2007). Testing and analysis techniques usedto study the thermal degradation of flame retardant coatings. Paint Coat Ind, 37(4): 50–54 (in Chinese)
8. Li J (2003). Spectroscopy of Wood. Beijing: Science Press, 259–263 (in Chinese)
9. Wang Q W (2000). Principle on Fire-Retarding Technology of Wood. Harbin: NortheastForestry University Press, 141–154 (in Chinese)
10. Wang Q W, Zhang Z J, Chen L, Wang F Q (2006). Effects of oxygen concentration on the smoking property of fire-retardanttreated Wood. Sci Silv Sin, 42(12): 95–100 (in Chinese)
11. Xu X N, Xu W Y, Wu T (2005). Research on fire retardant coatingscoutaining expandable graphite using cone calorimeter. Fire Safe Sci, 14(1): 11–15 (in Chinese)
12. Zhang L, Wang J Q (2001). A newkind of halogen-free fire retardant coatings made from expandablegraphite. J Beijing Inst Tech, 21(5): 649–652 (in Chinese)
13. Zhang Z J (2007). Influence of oxygen concentration on the flammabilitycharacteristics of fire-retardant cellulose. Master's Dissertation. Harbin: Northeast Forestry University, 35–47