The viability of high-efficiency direct energy harvesting from a beta-emitting radioactive source was previously experimentally investigated using an apparatus based on an ionization chamber equipped with an internal positioning stage for the source. This novel concept uniquely leverages the direct collection of beta particles on a converter electrode, converting their kinetic energy into electrical power and enabling compact power sources. This approach offers ultra-long-life, maintenance-free solutions in applications where conventional batteries are impractical. To evaluate system performance, we employed Monte Carlo simulations to model electron transport, governed by continuous slowing down due to Coulomb interactions. Electron interactions in matter, dominated by elastic and inelastic scattering, can lead to ionization events accompanied by X-ray fluorescence or Auger electron emission. EGS5 Monte Carlo simulations were performed to study the response of an ionization chamber to a Ni-63 beta source under various electric field strengths. The simulated dosimetric response was compared with previous experimental measurements. Gas-filled ionization chambers, consisting of two electrodes in a controlled electric field, are widely used for radiation dosimetry. Simulations using four different chamber gases across a wide range of field strengths showed consistent agreement with measured dose responses. These results demonstrate that the developed simulation framework is an accurate and versatile tool for investigating electron behavior in gas-filled detectors. It can be confidently applied in future studies to explore alternative gases, field configurations, or radiation sources. Additionally, the findings support the feasibility of direct beta radiation harvesting, highlighting its potential for developing compact and efficient power sources.
The transition from isolated energy infrastructures to a deeply decarbonised system requires coordinated interaction among electricity, heating, cooling, hydrogen, gaseous fuels, transport, and industrial energy services. This study systematically reviews the renewable energy systems with special emphasis on design and energy storage strategies. The evidence indicates that direct electrification and electricity–heat coupling are generally preferable when conversion efficiency and short-to medium-duration flexibility dominate. In contrast, batteries are most suitable for fast response and intraday balancing. Thermal storage is particularly valuable in heat-and cooling-intensive applications because it can shift demand at comparatively low system cost. At the same time, hydrogen and derivative fuels become more relevant for long-duration, seasonal, industrial, and transport applications in which their infrastructure and conversion penalties are offset by cross-sector value. The review further shows that no modelling method is universally suitable: steady-state optimisation supports strategic planning, dynamic models support control and transient assessment, stochastic and robust approaches address uncertainty, and artificial-intelligence methods require physical constraints, interpretability, cybersecurity safeguards, and field validation. The principal contribution is a common multi-criteria framework based on efficiency, cost, carbon mitigation, infrastructure compatibility, flexibility duration, safety, maturity, and resilience. This framework converts a descriptive technology review into practical guidance for selecting coupling pathways, storage portfolios, and modelling methods under different system conditions.
The presence of intermittent sources of renewable energy in power systems requires ESSs to manage temporal imbalance in energy supply and demand. In this study, we introduce a hybrid energy storage system (HESS) coupled with an AI energy management system (EMS) that uses deep reinforcement learning (DRL) for optimal scheduling of renewable energy utilization within grid-connected and islanded microgrids. AI-enabled EMS utilizes a DRL agent with proximal policy optimization (PPO) to make optimal decisions regarding energy generation based on state space and economic considerations, while accounting for SoC constraints of batteries. An important aspect of the proposed system is the design of HESS architecture and reward function based on DRL. Further improvements are made via analysing the PPO clipping sensitivity, Pearson correlation analysis on the relationship between the intermittency of renewables and response latency, and Monte Carlo uncertainty analysis with a 95% confidence interval. For a 24-hour simulation period, the developed system is able to cut down on grid power imports by 43.2%, have an 87.3% renewable energy utilization rate, extend the lifespan of the battery from 8.1 to 12.5 years, and have 91.4% peak shaving efficiency through 100 Monte Carlo runs and without any SoC violations (25%–90%). Net benefit analysis is estimated to be $56,000–$66,000 for 15 years at a 6% discount rate, while a 120 ms response time and one-way ANOVA with Tukey’s HSD confirm statistical significance.
A The growing penetration of photovoltaic (PV) and wind generation in microgrids poses problems of fast-changing power and low inertia, which pose challenges for frequency regulation. Although traditional battery energy storage systems have the capacity for providing continuous energy supply, they might be subjected to increased stress due to the charging and discharging activities in response to high-frequency disturbances. The current paper aims at presenting an artificial intelligence-based real-time control architecture for the coordinated operation of a battery-supercapacitor hybrid energy storage system in a microgrid characterized by a high penetration of renewable energy sources. The developed architecture is able to make the necessary adjustments based on the values of frequency deviation, rate of change of frequency, renewable generation, load demands, battery state of charge, and supercapacitor voltage. The proposed scheme was simulated using MATLAB/Simulink under the conditions of moderately varying renewable sources, sudden load disturbances, highly intermittent renewables, and a combination of renewable and load disturbances. The maximum frequency deviation was lowered from 0.32 Hz to 0.18 Hz (−43.8%), and the frequency settling time decreased from 4.1 s to 2.6 s (−36.5%). The stress on the battery caused by high current during charging/discharging decreased by 31.2%, whereas the estimated increase in the battery lifetime was 27.6%. The energy utilization efficiency rose from 88.2% to 95.4%, and the battery state-of-charge (SOC) remained within the 35–85% operational limits. It is shown that the cooperation of storage systems can help increase the frequency stability and reduce the battery stress in a high-renewable microgrid. Future research will include hardware-in-the-loop (HIL) tests.
Commercialization of lithium metal batteries with high energy density is limited largely due to uncontrolled lithium dendrite growth, poor interfacial resistance of solid-state electrolytes, and inadequate cycle stability of solid-state electrolytes. A new architecture that leverages artificial intelligence to design engineered nanolayer interfaces for solid-state electrolytes enables controlled lithium-ion transport and prevents dendrite propagation in next-generation batteries. To achieve this, the proposed framework combines multiphysics interfacial modeling with an artificial intelligence optimization module to simultaneously determine the optimal thickness and interfacial parameters for nanolayers to optimize ionic conductivity while minimizing electrochemical degradation. Simulation results show that the engineered interface provides a significantly better electrochemical performance than any existing solid-state electrolyte configuration. The simulation results show that the optimized nanolayer-engineered interface gave an ionic conductivity of 1.21 × 10−3 S cm−1, which was an enhancement of 34.8% compared to the conventional interface. This framework helped reduce interfacial resistance to 46 Ω cm2 from 82 Ω cm2, which was an improvement of 43.9%, and increased the critical current density to 2.1 mA cm−2 from 1.3 mA cm−2. Additionally, the optimized interface retained 93.4% of its capacity after 500 cycles of charge-discharge, which is an improvement of 93.4% from the conventional interface’s 79.6%. Collectively, these results indicate that the combination of nanolayer engineering and artificial intelligence optimization enables uniform deposition of lithium ions, enhances interfacial stability, and reduces the degree of dendrite-induced degradation. The proposed framework enables large-scale development of safer, long-lasting solid-state lithium-ion batteries and facilitates high-energy-density storage for electric vehicles and large renewable energy systems.
The utilization of renewable energy technologies like solar photovoltaics (PVs) and wind energy faces many operational difficulties because of their unpredictable and intermittent nature. Multi-energy hubs in combination with advanced energy storage facilities may serve as an effective solution for dealing with these problems. This paper presents a stochastic optimization model for operation of the hydrogen-battery-based multi-energy hub in a highly stochastic renewable energy environment. The stochastic optimization model proposed in this paper takes into account the integration of solar PV, wind turbines, battery energy storage system, hydrogen storage, electrolyzers, fuel cell, CHP, and heat pump within the energy management system. Uncertainty in renewable energy production is described using probability distribution functions. To create 1,000 stochastic scenarios of renewable energy production, the Monte Carlo simulation approach is used. Fast forward selection and k-means clustering algorithms are applied to reduce the number of stochastic scenarios. Finally, an optimal two-stage stochastic MILP model is introduced for the decision-making process of day ahead and real time operations. It is found that the coexistence of battery and hydrogen energy storage systems improves system performance significantly. The results from simulations show that the proposed model is quite effective in minimizing operating costs by 33%, making use of 91.7% of the renewable energy, reducing energy from the grid by 28.4%, and cutting carbon emissions by 24.8% when compared to deterministic scheduling. Moreover, the use of scenario reduction made the computational complexity drop by about 95% without making the approximation error go beyond 1%.
Degradation in lithium-ion batteries employed for ultra-long duration energy storage (LDES) greatly restricts the performance, dependability, and remaining useful life (RUL) predictability of such devices. Current methods tend to emphasize either material degradation or data-driven prognostic approaches and seldom incorporate the notions of self-healing and intelligent prognosis. A novel paradigm of degradation-aware self-healing electrodes is introduced by combining a composite core-shell electrode, a reversible self-healing matrix, embedded multi-modal sensing, and a physics-informed hybrid predictive model. It enables monitoring of mechanical stress, impedance increase, temperature, and capacity degradation, leading to a closed loop of degradation detection, self-healing, and adaptive RUL prediction. The approach was analyzed via simulations under representative long-duration battery operation and contrasted with the traditional lithium-ion electrode. The suggested framework demonstrated substantial improvements in electrochemical durability and prediction performance. The cycle life of the battery has been extended to 2,100 charge-discharge cycles from 1,200 charge-discharge cycles, and capacity retention after 1,000 cycles rose from 68% to 86%. The impedance increase was significantly decreased by approximately 40%, and the normalized stress increase decreased from 1.00 to 0.62. The capacity fade rate dropped from 1.8% to 0.9% per 100 cycles. Also, the hybrid prediction framework lowered the error rate of RUL prediction from 18.4% to 6.7%, outperforming traditional predictive frameworks. The statistical analysis conducted across 10 simulation runs proved the significance of the observed changes (two-tailed paired t-test, p < 0.001). The suggested degradation-aware self-healing framework proves the potential of combining autonomous recovery and hybrid prediction in order to improve both the battery’s durability and its prognostic performance at once. This closed-loop system is able to prevent the negative effects caused by degradation on battery performance and improve reliability.
The development of sustainable and cost-effective electrode materials is crucial for advancing metal–air battery technology and reducing dependence on conventional carbon resources. This study explores coal fly ash and Municipal Solid Waste Gasification (MSWG) char as waste-derived electrode precursors, utilizing their mineral-rich and carbonaceous characteristics to improve electrochemical performance. The objectives were to characterize the raw materials’ elemental composition and surface functional groups and to comparatively evaluate three hybrid-electrode formulations based on their pore characteristics, electrochemical response, and charge-transfer behaviour. SEM–EDX showed coal fly ash with spherical, microsphere-like particles rich in O, Si, and Al, indicating its role as a mineral-rich silicate and aluminosilicate precursor. MSWG char, however, exhibited irregular, rough, agglomerated morphology with higher carbon content, serving as the main carbon source. FTIR confirmed silicate, oxide, hydroxyl, carbonate, and carbon–mineral bonding. Among the three formulations tested, the formulation containing 20 wt.% coal fly ash (F20) showed the best overall performance, with the highest micropore surface area (1.601 m2 g−1) and volume (0.0006110 cm3 g−1). It delivered the largest CV response, energy density of ~208 Wh kg−1, power density of 17.8 W kg−1, and the lowest ΔZ′ of 0.137 Ω. The descriptive results indicate that the measured performance may depend on active-pore accessibility and ion–electron transport characteristics rather than on total BET surface area alone. Further replicated experiments are required to establish the statistical reliability of the observed differences. This study advances waste-ash-derived electrodes for sustainable metal–air battery applications. The novelty of this work is the integrated composition–pore–transport evaluation of directly blended coal fly ash and MSWG char hybrid electrodes.
Despite the theoretical benefits of the half-cut cells over the traditional full-cell monocrystalline panel, there is limited comparative analysis showing its power output by comparing voltage, current, efficiency and other parameters between both panels under varying sunlight conditions; thus this research aimed to evaluate and compare the performance of both panel technologies in terms of voltage, current, and power output at different times of the day, while also considering environmental factors such as temperature, humidity, and solar irradiance. An experimental research design was adopted using two 400 W solar panels with measurements taken simultaneously at 2.5 h intervals between 10:00 am and 3:00 pm for a period of three months under two scenarios-without shading and with shading. The findings revealed that while the traditional panels consistently produced higher voltage values, the half-cut panels generated significantly higher current outputs resulting in greater overall power generation. Statistical analysis including percentage variance, and standard deviation reveal that the energy yield of the half cut is slightly higher than that of the full cut; but the Analysis of Variance (ANOVA) carried out to deepen the result of the statistical analysis depict that there is no significant difference in the power generation of both technologies under the ‘without shading’ scenario. However, from the ANOVA, a significant difference under the ‘with shading’ scenario with the half-cut panels having a higher power generation thus confirming the superior energy yield and performance stability of the half-cut panels under all environmental conditions including shading when compared to their traditional full-cell counterpart.
The increasing adoption of electric bicycles and motorcycles has intensified the demand for sustainable and reliable charging infrastructures, particularly in campus environments characterized by fluctuating mobility patterns and renewable energy variability. This study proposes an intelligent hybrid solar–wind renewable charging framework integrated with Long Short-Term Memory–Marine Predators Algorithm (LSTM-MPA) optimization to improve adaptive forecasting, charging stability, and renewable energy utilization. The methodology combined systematic meta-analysis and deep learning simulation approaches. A total of 30 empirical studies were analyzed using PRISMA-based selection procedures, risk-of-bias assessment, effect-size evaluation, and publication bias analysis. Experimental renewable energy datasets consisting of photovoltaic (PV), wind turbine, and charging parameters were modeled using the proposed hybrid LSTM-MPA architecture. The results demonstrated that Solar-Wind-Deep Learning systems achieved the highest average effect size of 20.653. The forecasting model achieved Root Mean Square Error (RMSE) values of 115.70–125.65 and Mean Absolute Error (MAE) values of 90.34–93.64, while training and validation losses decreased by more than 39%, indicating stable convergence. Operational analysis showed that hybrid renewable generation consistently exceeded campus charging demand, maintaining battery State of Charge (SoC) near 100% and resulting in a cumulative renewable energy generation of 43,235.30 kWh. Annual renewable energy exceeded 2,070 kWh with a maximum energy balance of 882.64 kWh. The system was economically feasible, achieving an IRR of 14.9% and positive cumulative cash flow after the seventh operational year, while reducing cumulative CO2 emissions by more than 22,450 kg over 20 years.
As more battery electric vehicles (BEVs) are being introduced, the need for accurate traction motor sizing to achieve optimal performance, energy efficiency, driving range and cost has become more important. The conventional analytical sizing methods are based on worst-case conditions and often result in over-or under-sizing a motor, with the resulting negative impact on system efficiency and economic viability. In this study, a MATLAB/Simulink model is developed which compares directly between analytical sizing and drive cycle-based simulation of a battery electric four-wheeler for a Maruti Zen passenger car. The equations of the vehicle dynamics with the four forces: rolling resistance, aerodynamic drag, acceleration, and gradient force approximate the tractive force, wheel torque, and motor power. The vehicle is tested in three standardised drive cycles (New European Driving Cycle (NEDC), Highway Fuel Economy Test (HWFET) and the Artemis Urban Drive Cycle (UDC)), and the results are compared to the analytical method. The analytical approach predicts a 23.23–67.99 kW power band for the road gradient range (0°–18°) analysed, while drive-cycle simulation suggests 15.29 kW (NEDC), 14.52 kW (HWFET) and 22.10 kW (UDC)-a 67.5–78.6% decrease from the analytical upper bound. The results show that drive-cycle-based sizing can provide a more accurate, application-specific assessment of traction-motor sizing and help to minimize the risk of over-sizing and increase efficiency. In addition to re-working known vehicle-dynamics equations, this work is novel in that the power gap between the two routes of analytical and drive-cycle sizing is benchmarked for a vehicle and set of parameters, and a low-cost, practical screening tool for selecting a traction motor appropriate for the operating environment and duty profile is provided to manufacturers and researchers.
This study evaluates the solar-to-electrical energy conversion performance of a 63.24 kWp grid-connected photovoltaic (PV) farm equipped with a Huawei SUN2000-60KTL-M0 (60 kW) inverter by comparing a steady-state diagnostic model against a dynamic observability assessment. A single-instant snapshot of 12 PV strings on 26 June 2026 identified three non-producing strings (PV6, PV7, PV8), reducing string availability to 75.0% and causing an instantaneous DC power shortfall of approximately 6.0 kW (23.6% of currently achievable capacity). Inverter DC-to-AC conversion efficiency was 98.72% and the observed daily-equivalent capacity factor was 15.48%, both computed directly from measured values. Performance Ratio is reported as not evaluable due to the absence of temporally overlapping plane-of-array irradiance data. The dynamic assessment evaluates day-to-day energy temporal variability and historical hourly weather variability from measured June 2026 and 2020–2025 records (mean absolute daily ramp 12.66%, daily energy CV 19.45%), while sub-minute electrical transient characteristics remain not evaluable owing to the lack of sub-minute electrical logging. A Model Observability Score (MOS) and Data Resolution Adequacy Index (DRAI) are computed from an a priori parameter registry. The steady-state model achieves an MOS of 87.5% (7 of 8 applicable parameters), while the dynamic model achieves 25.0% (4 of 16), with the gap concentrated in the electrical-transient domain and attributable to instrumentation limitations. A phased instrumentation roadmap is proposed. The findings provide a transparent, auditable template for determining appropriate monitoring depth in tropical grid-connected PV operations and maintenance practice.
In this study, authors present a complete energy system optimization framework of R1234yf based hybrid nanorefrigerant and hybrid nanolubricant system for improving the thermodynamic, economic, environmental and energy performance of vapor compression refrigeration system for Indian operating conditions. Six nano-particles (Al2O3, TiO2, CuO, SiO2, graphene nanoplatelets (GNP) and multi-walled carbon nanotubes (MWCNT)) were assessed for the thermophysical parameters, dispersion stability, coefficient of performance (COP) of the system, exergy efficiency, energy consumption of the compressor, life-cycle economics, environmental impact, and artificial intelligence-based prediction. The results show that the thermal conductivities of nanorefrigerants are significantly better than those of the conventional refrigerants, and the COP of the R1234yf system is improved closer to the COP of the conventional refrigerants, with the Al2O3–SiO2/PAG hybrid nanolubricant being more stable, while also reducing the power consumption of the compressor and improving the exergy efficiency. Both economic analysis and environmental assessment show good payback periods and significant reductions in indirect carbon emissions. The energy optimization of the system can be performed quickly and accurately with high reliability using the artificial neural network models. The proposed hybrid nanorefrigerant approach not only enables energy conservation and sustainable cooling but also paved a way for the HVAC systems to be compatible with renewable energy resources and to become low-carbon refrigeration technologies, directly contributing to Sustainable Development Goal 7 (Affordable and Clean Energy) via its high energy efficiency and its contribution to cooling in an environmentally friendly way.