Aim: Distal locking during intramedullary nailing remains a technically demanding step. The aim of this study was two-fold: first, to evaluate whether the proposed locking technique reduces radiation exposure and operative duration compared with the conventional free-hand technique across surgeons with different levels of experience; second, to compare its performance with previously published alternative distal locking methods.

Methods: A retrospective observational study was conducted across three trauma centers in Belgium. A total of 432 patients undergoing intramedullary nailing for long-bone fractures were included. Thirty surgeons (10 junior residents, 10 senior residents, 10 board-certified surgeons) performed distal locking using both the conventional free-hand technique and the proposed method. Radiation exposure and procedure duration were recorded and compared. Results were also compared with published data on alternative distal locking techniques.

Results: The proposed technique significantly reduced radiation exposure, fluoroscopy time, and procedure duration across all experience levels. Mean radiation dose decreased from 35.47 ± 8.9 to 4.43 ± 1.1 cGy/cm2 (p < 0.0001). Fluoroscopy time decreased from 19.33 ± 6.2 to 11.5 ± 2.0 seconds (p = 0.003). Procedure duration decreased from 9.53 ± 3.1 to 4.23 ± 1.2 minutes (p < 0.0001). The greatest improvement was observed among less experienced surgeons. Compared with published techniques, the method demonstrated non-inferior or superior results in terms of radiation exposure and procedure duration.

Conclusions: This simple and reproducible technique significantly reduces radiation exposure and operative time compared with the free-hand method. By eliminating the need to obtain a nearly perfectly round fluoroscopic image of the locking hole, the technique relies on hand-eye coordination and cognitive alignment rather than fixed geometric positioning. It requires fewer adjustments and repositioning of the C-arm. Its performance is comparable or superior to alternative techniques. It requires no additional equipment, making it practical for routine trauma practice.

Keywords

intramedullary nailing / femoral fracture / tibial fracture / distal locking / long bone fractures / radiation reduction / surgical technique

Cite this article

Download citation ▾
Sebastien D’ulisse, Luana Fakhouri, Hamlet Mirzoyan, Jacques Hernigou, Sagi Martinov. Distal locking of intramedullary nails with reduced radiation exposure and operating time using standard equipment. Exploration of Musculoskeletal Diseases, 2026, 4 (1) : 1007127 DOI:10.37349/emd.2026.1007127

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

Ryan-Coker MFD, Batura R, Kubai H, Forde MYE, Perdomo-Lizarraga JC, Marenah K, et al. Outcomes of intramedullary nailing for traumatic adult femoral shaft fractures in low-and-middle-income countries; a systematic review. OTA Int. 2025; 8: e434.

[2]

Boraiah S, Barker JU, Lorich D. Efficacy of an aiming device for the placement of distal interlocking screws in trochanteric fixation nailing. Arch Orthop Trauma Surg. 2009; 129: 1177-82.

[3]

Ehlinger M, Dillman G, Czekaj J, Adam P, Taglang G, Brinkert D, et al. Distal targeting device for long Gamma nail(®). Monocentric observational study. Orthop Traumatol Surg Res. 2013; 99: 799-804.

[4]

Maqungo S, Horn A, Bernstein B, Keel M, Roche S. Distal interlocking screw placement in the femur: free-hand versus electromagnetic assisted technique (sureshot). J Orthop Trauma. 2014; 28: e281-3.

[5]

Grimwood D, Harvey-Lloyd J. Reducing intraoperative duration and ionising radiation exposure during the insertion of distal locking screws of intramedullary nails: a small-scale study comparing the current fluoroscopic method against radiation-free, electromagnetic navigation. Eur J Orthop Surg Traumatol. 2016; 26: 867-76.

[6]

Wang Y, Han B, Shi Z, Fu Y, Ye Y, Jing J, et al. Comparison of free-hand fluoroscopic guidance and electromagnetic navigation in distal locking of tibia intramedullary nails. Medicine (Baltimore). 2018; 97: e11305.

[7]

Zhao X, Fan Y, Chen J. A comparison of free-hand method and electromagnetic navigation technique for the distal locking during intramedullary nailing procedures: a meta-analysis. Arch Orthop Trauma Surg. 2021; 141: 45-53.

[8]

Lyu F, Tu P, Tao X, Wang H. Development and evaluation of a novel mixed reality-based surgical navigation system for distal locking of intramedullary nails. Electronics. 2025; 14: 2486.

[9]

Gao H, Liu Z, Bai X, Xu G, Chen W, Ma J, et al. Comparison of freehand technique and a novel laser guiding navigation in distal locking of femoral intramedullary nails: a randomized controlled trial. BMC Surg. 2022; 22: 363.

[10]

Davut S, Doğramacı Y. Endoscopy-assisted distal locking of an intramedullary nail: A new experimental technique to reduce radiation exposure during distal locking of the intramedullary nails. Jt Dis Relat Surg. 2021; 32: 642-8.

[11]

Shang Y, Wang Y. Comparison of Free-hand and K-wires Technique in Distal Locking of Expert Tibia Nail. J Coll Physicians Surg Pak. 2023; 33: 474-6.

[12]

Menekse S. Fluoroscopy-free distal screw locking in intramedullary nailing: A retrospective study. Medicine (Baltimore). 2023; 102: e35276.

[13]

Deslivia MF, Kim HJ, Kim SH, Lee SJ. Straightforward, safe, and efficient interlocking screw insertion during intramedullary nailing using a Steinmann pin and hammer: a comparative study. Ewha Med J. 2024; 47: e39.

[14]

Chabihi Z, Nouidi N, Demnati B, Benhima MA, Abkari I. Fast and accurate distal locking of interlocked intramedullary nails using computer-vision and a 3D printed device. 3D Print Med. 2024; 10: 28.

[15]

Bhogal H, Martinov S, Buteau P, Bath O, Hernigou J. Bone conductivity and spine fluoroscopy, Hand-Eye-Ear dialogue, during pedicle screw positioning: a new human cognitive system for precision and radiation-decrease; better than artificial intelligence and machine learning system? Int Orthop. 2023; 47: 421-8.

PDF (5604KB)

0

Accesses

0

Citation

Detail

Sections
Recommended

/