3D printed hernia mesh implant: a conformability study

Abhishek Barwar , Prateek Kala , Rupinder Singh , J. Paulo Davim

Exploration of Biomat-X ›› 2024, Vol. 1 ›› Issue (4) : 266 -279.

PDF (8393KB)
Exploration of Biomat-X ›› 2024, Vol. 1 ›› Issue (4) :266 -279. DOI: 10.37349/ebmx.2024.00019
Original Article
research-article
3D printed hernia mesh implant: a conformability study
Author information +
History +
PDF (8393KB)

Abstract

Aim: This study aims to explore the sensing capabilities of polyvinylidene fluoride-hydroxyapatite-chitosan (PVDF-HAP-CS) composite-based hernia mesh implants (of conformal/planar design), followed by in-vitro analysis for better understanding of the bio-stability in the patient’s body. Methods: For analyzing the sensing capabilities, a microstrip patch antenna (MPA)-based implantable sensor [with 17-4 precipitate hardened (PH) stainless steel (SS) (bio-compatible) and Cu alloy (non-biocompatible) materials as conducting plane/patch with PVDF-HAP-CS as dielectric material] has been considered separately in this study. Primarily, in this study, the 3D models of the hernia mesh implant have been designed in the high-frequency structure simulator (HFSS) software, and the sensing behaviour of the same has been recorded. Results: The HFSS results represent that for the 17-4PH SS-based sensor, resonant frequency (fr) decreases from 2.3953 to 2.3800 GHz, whereas the gain increases from 0.54 to 4.02 dB with a SAR value of 1.077 W/kg. The fr for Cu alloy increases up to 30° conformal angle and, after that, starts decreasing, whereas the gain reaches 3.24 dB with a SAR value of 1.238 W/kg. The in-vitro study highlights that both materials (17-4PH SS and Cu alloy) possess a low corrosion rate. Conclusions: The simulation-based comparison of the biosensors with conducting elements 17-4PH SS and Cu alloy for different conformal angles indicates that the 17-4PH SS shows promising results over Cu in terms of higher gain (up to 4.02 dB) and low SAR value (1.077 W/kg) with the fr lying in the industry scientific and medical (ISM) band and therefore may be used for implantable sensor applications and possesses the capability to be used as 3D-printed hernia mesh implant. The in-vitro results with the low corrosion rate ≈ of 5.1 × 10–8 mm/year, 17-4PH SS may be a suitable material for the fabrication of hernia mesh implant.

Keywords

Implantable sensor / hernia mesh / conformal design / in-vitro analysis / PVDF composite / HFSS

Cite this article

Download citation ▾
Abhishek Barwar, Prateek Kala, Rupinder Singh, J. Paulo Davim. 3D printed hernia mesh implant: a conformability study. Exploration of Biomat-X, 2024, 1 (4) : 266-279 DOI:10.37349/ebmx.2024.00019

登录浏览全文

4963

注册一个新账户 忘记密码

References

[1]

ISO/ASTM 52900: 2021(en) Additive manufacturing - General principles - Fundamentals and vocabulary [Internet]. West Conshohocken (PA): ISO/ASTM; c2021 [cited 2024 Jun 28]. Available from: https://www.iso.org/obp/ui/#iso:std:iso-astm:52900:ed-2:v1:en

[2]

Kruth JP, Leu MC, Nakagawa T. Progress in additive manufacturing and rapid prototyping. CIRP Ann. 1998; 47: 525-40.

[3]

Peel S, Eggbeer D, Burton H, Hanson H, Evans PL. Additively manufactured versus conventionally pressed cranioplasty implants: An accuracy comparison. Proc Inst Mech Eng H. 2018; 232: 949-61.

[4]

Singh R, Barwar A, Kumar R, Kumar V. On mechanically recycled PLA-HAP-CS-based filaments for 3D printing of smart biomedical scaffolds. J Braz Soc Mech Sci Eng. 2022; 44: 416.

[5]

Yuan L, Ding S, Wen C. Additive manufacturing technology for porous metal implant applications and triple minimal surface structures: A review. Bioact Mater. 2018; 4: 56-70.

[6]

Trenfield SJ, Madla CM, Basit AW, Gaisford S. The shape of things to come: Emerging applications of 3D printing in healthcare. In: Basit A, Gaisford S, editors. 3D printing of pharmaceuticals. Cham: Springer; 2018. pp. 1-19.

[7]

Brunello G, Sivolella S, Meneghello R, Ferroni L, Gardin C, Piattelli A, et al. Powder-based 3D printing for bone tissue engineering. Biotechnol Adv. 2016; 34: 740-53.

[8]

Calignano F, Manfredi D, Ambrosio EP, Iuliano L, Fino P. Influence of process parameters on surface roughness of aluminum parts produced by DMLS. Int J Adv Manuf Technol. 2013; 67: 2743-51.

[9]

Traini T, Mangano C, Sammons RL, Mangano F, Macchi A, Piattelli A. Direct laser metal sintering as a new approach to fabrication of an isoelastic functionally graded material for manufacture of porous titanium dental implants. Dent Mater. 2008; 24: 1525-33.

[10]

Hosseini S, Mirdamadi S, Nemati A. Porous Ti6Al4V scaffolds for dental implants: Microstructure, mechanical, and corrosion behavior. Proc Inst Mech Eng Part L. 2016; 230: 927-33.

[11]

Brown RN, Sexton BE, Chu TG, Katona TR, Stewart KT, Kyung H, et al. Comparison of stainless steel and titanium alloy orthodontic miniscrew implants: a mechanical and histologic analysis. Am J Orthod Dentofacial Orthop. 2014; 145: 496-504.

[12]

Mutlu I, Oktay E. Biocompatibility of 17-4 PH stainless steel foam for implant applications. Biomed Mater Eng. 2011; 21: 223-33.

[13]

Pooniya R, Palsania SK, Saini R, Kumar A, Lal M, Kumar H. Surgico-therapeutic management of diaphragmatic hernia in buffalo: A review of 8 cases. Pharma Innovation J. 2022; SP-11: 2118-23.

[14]

Sharma K, Sangwan V, Kumar A, Singh N, Singh T, Mohindroo J. Diagnosis and surgical outcome of diaphragmatic herniorrhaphy in cows. Large Anim Rev. 2024; 30: 43-50.

[15]

Athar H, Mohindroo J, Singh K, Kumar A, Raghunath M. Comparison of radiography and ultrasonography for diagnosis of diaphragmatic hernia in bovines. Vet Med Int. 2010; 2010: 939870.

[16]

Blount AL, Craft RO, Harold KL, Roberts CC. Laparoscopic Repair of a Chronic Iatrogenic Diaphragmatic Hernia. Radiol Case Rep. 2015; 4: 304.

[17]

Valente A, Brereton RJ. Unilateral agenesis of the diaphragm. J Pediatr Surg. 1987; 22: 848-50.

[18]

Geisler F, Gotlieb A, Fried D. Agenesis of the right diaphragm: repaired with marlex. J Pediatr Surg. 1977; 12: 587-8.

[19]

Bekdash B, Singh B, Lakhoo K. Recurrent late complications following congenital diaphragmatic hernia repair with prosthetic patches: a case series. J Med Case Rep. 2009; 3: 7237.

[20]

Sugarbaker DJ, Jaklitsch MT, Bueno R, Richards W, Lukanich J, Mentzer SJ, et al. Prevention, early detection, and management of complications after 328 consecutive extrapleural pneumonectomies. J Thorac Cardiovasc Surg. 2004; 128: 138-46.

[21]

Lee SL, Poulos ND, Greenholz SK. Staged reconstruction of large congenital diaphragmatic defects with synthetic patch followed by reverse latissimus dorsi muscle. J Pediatr Surg. 2002; 37: 367-70.

[22]

Saxena P, Shukla P. A comprehensive review on fundamental properties and applications of poly(vinylidene fluoride) (PVDF). Adv Compos Hybrid Mater. 2021; 4: 8-26.

[23]

Lei K, Hsieh Y, Chiu Y, Wu M. The Structure Design of Piezoelectric Poly(vinylidene Fluoride) (PVDF) Polymer-Based Sensor Patch for the Respiration Monitoring under Dynamic Walking Conditions. Sensors (Basel). 2015; 15: 18801-12.

[24]

Ranjan N, Singh R, Ahuja IP, Singh J. Fabrication of PLA-HAp-CS based biocompatible and biodegradable feedstock filament using twin screw extrusion. In: AlMangour B, editor. Additive Manufacturing of Emerging Materials. Cham: Springer; 2019. pp. 325-45.

[25]

Kiourti A, Nikita KS. A review of implantable patch antennas for biomedical telemetry: Challenges and solutions [Wireless Corner]. IEEE Antennas Propag Mag. 2012; 54: 210-28.

[26]

Soontornpipit P, Furse CM, Chung YC. Design of implantable microstrip antenna for communication with medical implants. IEEE Transactions Microwave Theory Tech. 2004; 52: 1944-51.

[27]

Kiziltas G, Psychoudakis D, Volakis JL, Kikuchi N. Topology design optimization of dielectric substrates for bandwidth improvement of a patch antenna. IEEE Trans Antennas Propag. 2003; 51: 2732-43.

[28]

Kiourti A, Nikita KS. Meandered versus spiral novel miniature PIFAs implanted in the human head: Tuning and performance. In: Nikita KS, Lin JC, Fotiadis DI, Arredondo Waldmeyer MT, editors. Proceedings of MobiHealth: International Conference on Wireless Mobile Communication and Healthcare; 2011 Oct 5- 7; Kos Island, Greece. Berlin: Springer; 2012. pp. 80-7.

[29]

Singh R, Kumar S, Singh AP, Wei Y. On comparison of recycled LDPE and LDPE-bakelite composite based 3D printed patch antenna. Proc Inst Mech Eng Part L. 2022; 236: 842-56.

[30]

Boparai KS, Singh R, Kumar A, Pradhan SR, Khan MM. On Tribological and In-vitro Analysis of Meta-Structure-Based 3D Printed Horse Hoof Strap. Natl Acad Sci Lett. 2023; 46: 117-21.

[31]

Singh S, Singh G, Prakash C, Ramakrishna S, Lamberti L, Pruncu CI. 3D printed biodegradable composites: An insight into mechanical properties of PLA/chitosan scaffold. Polym Test. 2020; 89: 106722.

[32]

Husain M, Singh R, Pabla BS. A review on 3D printing of partially absorbable implants. J Inst Eng (India) Series C. 2023; 104: 1113-32.

[33]

Singh R, Singh G, Anand A. On 3D printed intelligent diaphragmatic hernia sensor. Rapid Prototyping J. 2024; 30: 323-37.

PDF (8393KB)

0

Accesses

0

Citation

Detail

Sections
Recommended

/