Beyond traditional brittleness: A novel post-peak ductility index (PDI) for assessing fracture energy in eco-friendly hybrid concretes
Grzegorz Ludwik Golewski
AIMS Materials Science ›› 2026, Vol. 13 ›› Issue (5) : 976 -995.
The development of sustainable structural concrete increasingly incorporates supplementary cementitious materials (SCMs) and nanoadditives to drastically reduce carbon footprints. However, microstructural densification using nanosilica (NS) and silica fume (SF) often enhances compressive strength at the expense of increased structural brittleness. Traditional engineering methods evaluate this brittleness through empirical static strength ratios (e.g., the brittleness index, BI), which inherently fail to reflect the post-cracking energy dissipation mechanisms and non-linear softening behavior. To overcome this limitation, we introduced a novel energy-based metric designated as the post-peak ductility index (PDI), which mathematically isolates the post-peak energy (Wpost) relative to the total work of fracture (Wt). An extensive experimental campaign was conducted on four distinct concrete formulations: a 100% ordinary Portland cement (OPC), reference concrete (REF), a ternary nano-composite (NSF, containing 5% NS and 10% SF), and two quaternary hybrid systems combining 5% NS, 10% SF, and varying contents of fly ash (FA) (5% and 15% FA) (quaternary hybrid concretes: H1 and H2). The holistic mechanical and fracture performance was characterized via three-point bending tests on notched beams, coupled with advanced multi-criteria radar chart mapping and Pearson correlation matrix analysis. The experimental results demonstrated a beneficial interaction in the quaternary formulation H1, which achieved a 48% increase in compressive strength alongside a 145% explosion in the Wt (Wt = 2.012 J) compared to the REF concrete. Furthermore, while the sole addition of NS increased matrix brittleness (reducing PDI to 85.01%), the inclusion of FA successfully restored ductility (PDI up to 89.71%). Statistical validation confirmed that the classical BIcorrelates negatively with actual fracture work, proving its inadequacy for high-performance formulations, whereas the proposed PDI accurately tracks true non-linear structural safety margins.
post-peak ductility index (PDI) / brittleness index (BI) / quaternary hybrid concrete / siliceous fly ash (FA) / silica fume (SF) / nanosilica (NS) / non-linear fracture mechanics / softening behavior / total fracture energy (Gf) / multi-criteria evaluation
| [1] |
|
| [2] |
|
| [3] |
|
| [4] |
|
| [5] |
|
| [6] |
|
| [7] |
|
| [8] |
Bao S, Xie T, Chen H, |
| [9] |
|
| [10] |
|
| [11] |
|
| [12] |
|
| [13] |
|
| [14] |
Ahmed A (2024) Assessing the effects of supplementary cementitious materials on concrete properties: A review. Disc Civ Eng 1: 145. https://doi.org/10.1007/s44290-024-00154-z |
| [15] |
|
| [16] |
|
| [17] |
|
| [18] |
|
| [19] |
|
| [20] |
|
| [21] |
|
| [22] |
|
| [23] |
|
| [24] |
|
| [25] |
|
| [26] |
|
| [27] |
|
| [28] |
|
| [29] |
|
| [30] |
|
| [31] |
|
| [32] |
|
| [33] |
|
| [34] |
|
| [35] |
|
| [36] |
|
| [37] |
|
| [38] |
|
| [39] |
|
| [40] |
|
| [41] |
|
| [42] |
|
| [43] |
|
| [44] |
|
| [45] |
|
| [46] |
|
| [47] |
|
| [48] |
|
| [49] |
|
| [50] |
|
| [51] |
|
| [52] |
|
| [53] |
|
| [54] |
|
| [55] |
|
| [56] |
|
| [57] |
Golewski GL (2024) Effect of coarse aggregate type on the fracture toughness of ordinary concrete. Infrastructures 11: 105509. https://doi.org/10.3390/infrastructures9100185 |
| [58] |
|
| [59] |
|
| [60] |
|
| [61] |
|
| [62] |
|
| [63] |
|
| [64] |
|
| [65] |
|
| [66] |
|
| [67] |
|
| [68] |
|
| [69] |
|
| [70] |
|
| [71] |
|
| [72] |
|
| [73] |
|
| [74] |
|
| [75] |
EN 197-1: 2011 (2011) Cement-Part 1: Composition, specifications and conformity criteria for common cements. NSAI Standard: Dublin, Ireland. |
| [76] |
ASTM C 618-03 (2008) Standard specification for coal fly ash and raw or calcined natural pozzolan for use in concrete. Annual book of ASTM standard: West Conshohocken, PA, USA. |
| [77] |
EN 1008: 2002 (2002) Mixing water for concrete-specification for sampling, testing and assessing the suitability of water, including water recovered from processes in the concrete industry, as mixing water for concrete. British Standards Institution (BSI): London, UK. |
| [78] |
|
| [79] |
Odler I (1991) Strength of cement (final report). Mater Struct 24: 143-157. https://doi.org/10.1007/BF02472476 |
| [80] |
|
| [81] |
|
| [82] |
DIN 4226-1:2001-07 (2001) Aggregates for concrete and mortar-Part 1: Normal and heavy-weight aggregates. German Standards Institution: Essen, Germany. |
| [83] |
EN 13791: 2019-12 (2019) Assessment of in-situ compressive strength in structures and precast concrete components. British Standards Institution (BSI): London, UK. |
| [84] |
EN 12390-2:2019 (2019) Testing hardened concrete-Part 2: Making and curing specimens for strength tests. British Standards Institution (BSI): London, UK. |
| [85] |
EN 12390-3:2011+AC (2012) Testing hardened concrete-Part 3: Compressive strength of test specimens. British Standards Institution (BSI): London, UK. |
| [86] |
EN 12390-6:2009 (2009) Testing hardened concrete-Part 6: Tensile Splitting strenght of test specimens. British Standards Institution (BSI): London, UK. |
| [87] |
Golewski GL (2024) Comparison of fracture behavior of set concretes based on natural and crushed aggregates. Mater Res Express 11: 105509. https://doi.org/10.1088/2053-1591/ad87b4 |
| [88] |
|
| [89] |
RILEM TC 50-FMC (1985) Determination of the fracture energy of mortar and concrete by means of three-point bend tests on notched beams. Mater Struct 18: 285-290. https://doi.org/10.1007/BF02472918 |
| [90] |
|
| [91] |
|
| [92] |
|
| [93] |
|
| [94] |
|
| [95] |
|
| [96] |
|
| [97] |
|
| [98] |
|
| [99] |
|
| [100] |
Kaur Sood S, |
/
| 〈 |
|
〉 |